Now showing1 - 3 of 3
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Standard- und Spezialinlays in primärer Hüftendoprothetik : Aktuelle Studien- und Umfrageergebnisse aus dem Endoprothesenregister Deutschland (EPRD)
    BACKGROUND: Instability constitutes the main reason for revision hip arthroplasties. Modified polyethylene liners are designed to improve the stability of a hip replacement. In July 2022 The Bone & Joint Journal published a study with data of the German Arthroplasty Registry (EPRD). The study investigated mechanical failure of standard and modified liner designs in primary, cementless total hip arthroplasty. Following the study, the EPRD conducted a survey of German clinics to research the utilization of lipped liners in primary total hip replacement. METHODS: The liner study included 151,096 primary, elective, cementless total hip arthroplasties. Data from November 2012 to November 2020 were obtained from the EPRD. Standard polyethylene liners were compared with lipped, angulated, offset and angulated/offset inlays. Cumulative incidences for endpoint revision due to mechanical complication were calculated with a competing risk analysis. The influence of other variables was investigated with a multivariate Cox regression. In the following online survey, 237 out of 789 hospitals completed a form. RESULTS AND CONCLUSION: In our analysis, only offset liners were, compared to standard liners, associated with a reduced risk of mechanical failure in a short to medium follow up. However, the resultant joint reaction force is increased with offset liners due to the lateralization of the hip center of rotation. Thus, the long-term performance of offset liners needs to be observed. Our survey indicated that lipped liners were implanted more often if the posterior approach was used. Moreover, lipped liners were mostly positioned with the elevated rim in the biomechanically less optimal posterior-superior quadrant. To improve stability it is suggested to position the elevated rim in the posterior-inferior quadrant.
    Publicationtype: Journal Article
      22
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Endoprothesenregister Deutschland (EPRD) : Jahresbericht 2023
    (EPRD Deutsche Endoprothesenregister gGmbH, 2023) ; ; ; ;
    Publicationtype: Book
      138
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Modified acetabular component liner designs are not superior to standard liners at reducing the risk of revision : an analysis of 151,096 cementless total hip arthroplasties from the German Arthroplasty Registry
    AIMS: Registry studies on modified acetabular polyethylene (PE) liner designs are limited. We investigated the influence of standard and modified PE acetabular liner designs on the revision rate for mechanical complications in primary cementless total hip arthroplasty (THA). METHODS: We analyzed 151,096 primary cementless THAs from the German Arthroplasty Registry (EPRD) between November 2012 and November 2020. Cumulative incidence of revision for mechanical complications for standard and four modified PE liners (lipped, offset, angulated/offset, and angulated) was determined using competing risk analysis at one and seven years. Confounders were investigated with a Cox proportional-hazards model. RESULTS: Median follow-up was 868 days (interquartile range 418 to 1,364). The offset liner design reduced the risk of revision (hazard ratio (HR) 0.68 (95% confidence interval (CI) 0.50 to 0.92)), while the angulated/offset liner increased the risk of revision for mechanical failure (HR 1.81 (95% CI 1.38 to 2.36)). The cumulative incidence of revision was lowest for the offset liner at one and seven years (1.0% (95% CI 0.7 to 1.3) and 1.8% (95% CI 1.0 to 3.0)). No difference was found between standard, lipped, and angulated liner designs. Higher age at index primary THA and an Elixhauser Comorbidity Index greater than 0 increased the revision risk in the first year after surgery. Implantation of a higher proportion of a single design of liner in a hospital reduced revision risk slightly but significantly (p = 0.001). CONCLUSION: The use of standard acetabular component liners remains a good choice in primary uncemented THA, as most modified liner designs were not associated with a reduced risk of revision for mechanical failure. Offset liner designs were found to be beneficial and angulated/offset liner designs were associated with higher risks of revision.
    Publicationtype: Journal Article
    Scopus© Citations 3  23