  4. Fatigue strength reduction of Ti–6Al–4V titanium alloy after contact with high-frequency cauterising instruments

Fatigue strength reduction of Ti–6Al–4V titanium alloy after contact with high-frequency cauterising instruments

Publikationstyp
Journal Article
Date Issued
2020-07
Sprache
English
Author(s)
Zobel, Sebastian Manuel
Morlock, Michael
Huber, Gerd
Institut
Biomechanik M-3
TORE-URI
http://hdl.handle.net/11420/6974
Journal
Medical engineering & physics
Volume
81
Start Page
58
End Page
67
Citation
Medical Engineering and Physics (81): 58-67 (2020-07)
Publisher DOI
10.1016/j.medengphy.2020.05.016
Scopus ID
2-s2.0-85085964610
PubMed ID
32513523
Contact of implants with high-frequency cauterising instruments has serious implications for patient safety. Studies have reported a possible direct connection of fatigue failure of Ti–6Al–4V implants with electrocautery contact. Such contacts were observed at the polished neck of titanium hip stems, which are subjected to high-tension loads. Evidence of electrocautery contact has also been found on a retrieved spinal fixator with a rough surface; however, no fatigue failure related to electrocautery contact has been reported thus far. The influence of the heat-affected zone caused by flashover on the mechanical behaviour of the Ti–6Al–4V titanium alloy is not yet fully understood. Then, the aim of this study was to investigate whether the polished areas of Ti–6Al–4V implants are especially susceptible to fatigue failure after electrocautery contact. Flashovers caused by electrocautery contact were induced on titanium specimens with different surface roughnesses. These specimens were subjected to cyclic loading in a four-point-bending test setup, which represented the stress resulting from physiological loading activities (~861 MPa). In this test setup, electrocautery contact was found to reduce the fatigue strength of the titanium alloy significantly—by up to 96%—as revealed from the median value of the cycles to failure. Cycles to failure showed a dependence on the flashover duration, with a flashover for 40 ms leading to fatigue fracture. Despite the lower fatigue strength of a rough polished surface in the undamaged state, it is less prone to the damaging effect of flashover than a smooth polished surface.
Subjects
Electrosurgery
Fatigue strength
Hip implant
Revision surgery
Spinal fixator
Ti–6Al–4V titanium alloy
TUHH
Weiterführende Links
  • Contact
  • Send Feedback
  • Cookie settings
  • Privacy policy
  • Impress
DSpace Software

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science
Design by effective webwork GmbH

  • Deutsche NationalbibliothekDeutsche Nationalbibliothek
  • ORCiD Member OrganizationORCiD Member Organization
  • DataCiteDataCite
  • Re3DataRe3Data
  • OpenDOAROpenDOAR
  • OpenAireOpenAire
  • BASE Bielefeld Academic Search EngineBASE Bielefeld Academic Search Engine
Feedback