Please use this identifier to cite or link to this item: https://doi.org/10.15480/882.1510
DC FieldValueLanguage
dc.contributor.authorJohn, Bibin-
dc.contributor.authorRanjan, Rajeev-
dc.contributor.authorSpink, Clemens-
dc.contributor.authorSchröder, Dietmar-
dc.contributor.authorKoops, Andreas-
dc.contributor.authorAdam, Gerhard-
dc.contributor.authorKrautschneider, Wolfgang-
dc.date.accessioned2018-02-01T15:02:00Z-
dc.date.available2018-02-01T15:02:00Z-
dc.date.issued2016-02-
dc.identifier.isbn978-0-88986-981-3de_DE
dc.identifier.isbn978-0-88986-980-6de_DE
dc.identifier.urihttp://tubdok.tub.tuhh.de/handle/11420/1513-
dc.description.abstractThis paper describes the design, implementation and testing of a wireless blood pressure sensing implant. The implant is mounted on a stent graft. The implant along with the stent graft must fit into a 16F applicator stent delivery system. The implant is powered using the energy harvested from wireless power transmission. The measured pressure data is sent wirelessly to an external data reader hardware. The pressure measurement must have resolution of 1 mmHg.en
dc.language.isoende_DE
dc.rightsinfo:eu-repo/semantics/openAccess-
dc.subjecttelemetryde_DE
dc.subjectwireless power transmissionde_DE
dc.subjectinductive couplingde_DE
dc.subjectImplantatde_DE
dc.subjectpressure measurementde_DE
dc.subject.ddc620: Ingenieurwissenschaftende_DE
dc.titleWireless blood pressure measurement implant electronics for integration in a stent craftde_DE
dc.typeinProceedingsde_DE
dc.identifier.urnurn:nbn:de:gbv:830-88218315-
dc.identifier.doi10.15480/882.1510-
dc.type.dinicontributionToPeriodical-
dc.subject.ddccode620-
dcterms.DCMITypeText-
tuhh.identifier.urnurn:nbn:de:gbv:830-88218315de_DE
tuhh.oai.showtrue-
dc.identifier.hdl11420/1513-
tuhh.abstract.englishThis paper describes the design, implementation and testing of a wireless blood pressure sensing implant. The implant is mounted on a stent graft. The implant along with the stent graft must fit into a 16F applicator stent delivery system. The implant is powered using the energy harvested from wireless power transmission. The measured pressure data is sent wirelessly to an external data reader hardware. The pressure measurement must have resolution of 1 mmHg.de_DE
tuhh.publisher.doi10.2316/P.2016.832-042-
tuhh.publication.instituteNano- und Medizinelektronik E-9de_DE
tuhh.identifier.doi10.15480/882.1510-
tuhh.type.opusInProceedings (Aufsatz / Paper einer Konferenz etc.)de
tuhh.institute.germanNano- und Medizinelektronik E-9de
tuhh.institute.englishNano- und Medizinelektronik E-9de_DE
tuhh.gvk.hasppnfalse-
tuhh.hasurnfalse-
openaire.rightsinfo:eu-repo/semantics/openAccessde_DE
dc.type.drivercontributionToPeriodical-
dc.type.casraiConference Paperen
dc.relation.conferenceThe 12th IASTED International Conference on Biomedical Engineering BioMed 2016de_DE
dc.rights.nationallicensefalsede_DE
item.fulltextWith Fulltext-
item.creatorOrcidJohn, Bibin-
item.creatorOrcidRanjan, Rajeev-
item.creatorOrcidSpink, Clemens-
item.creatorOrcidSchröder, Dietmar-
item.creatorOrcidKoops, Andreas-
item.creatorOrcidAdam, Gerhard-
item.creatorOrcidKrautschneider, Wolfgang-
item.creatorGNDJohn, Bibin-
item.creatorGNDRanjan, Rajeev-
item.creatorGNDSpink, Clemens-
item.creatorGNDSchröder, Dietmar-
item.creatorGNDKoops, Andreas-
item.creatorGNDAdam, Gerhard-
item.creatorGNDKrautschneider, Wolfgang-
item.grantfulltextopen-
crisitem.author.deptIntegrierte Schaltungen E-9-
crisitem.author.deptIntegrierte Schaltungen E-9-
crisitem.author.deptIntegrierte Schaltungen E-9-
crisitem.author.orcid0000-0001-8629-4545-
Appears in Collections:Publications (tub.dok)
Files in This Item:
File Description SizeFormat
wireless blood pressure measurement implant electronics for integration in a stent graft.pdfBioMed2016681,62 kBAdobe PDFThumbnail
View/Open
Show simple item record

Page view(s)

173
Last Week
3
Last month
7
checked on Apr 19, 2019

Download(s)

133
checked on Apr 19, 2019

Google ScholarTM

Check

Export

Items in TORE are protected by copyright, with all rights reserved, unless otherwise indicated.