Please use this identifier to cite or link to this item: https://doi.org/10.15480/882.1547
Fulltext available Open Access
Publisher DOI: 10.1243/095441105X69015
Title: Biomechanical, morphological, and histological analysis of early failures in hip resurfacing arthroplasty
Language: English
Authors: Morlock, Michael 
Bishop, Nicholas 
Rüther, Wolfgang 
Delling, Günter 
Hahn, Michael 
Keywords: Aged;Arthroplasty, Hip Replacement;Biomechanical Phenomena;Equipment Failure Analysis;Female;Femoral Fractures;Femur Head;Femur Head Necrosis;Hip Prosthesis;Humans;Male;Middle Aged;Surface Properties;Treatment Outcome;Prosthesis Failure
Issue Date: Feb-2006
Publisher: Sage Publ.
Source: Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine 2 (220): 333-344 (2006)
Journal or Series Name: Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine 
Abstract (english): The present revival of hip resurfacing arthroplasty may be related to an increase in early failures owing to the challenging technique of the procedure. Fifty-five retrieved implants were analysed with respect to wear, cement mantle and cement penetration, fracture and head morphology, as well as standard histology. Femoral neck fractures occurred in median after 102 days. The time to failure was shorter for older women. Major deviations from the suggested cement mantle thickness and cement penetration were found. Indications for high trauma during implantation leading to early failure due to weakening of the femoral neck were also observed. Some failures had signs of pseudarthrosis beneath the implant. Four different fracture patterns with different mean survival times were identified. Observed wear was minor with the exception of that due to alignment mistakes (rim loading). The cups were not damaged by the failures. Histological results indicate that avascular necrosis is not necessarily connected with this kind of endoprosthetic surgery. Most of the failures analysed can probably be attributed to the 'learning curve' effect, which is an unsatisfactory situation.
URI: http://tubdok.tub.tuhh.de/handle/11420/1550
DOI: 10.15480/882.1547
ISSN: 2041-3033
Institute: Biomechanik M-3 
Type: (wissenschaftlicher) Artikel
Permission Note: Dieser Beitrag ist mit Zustimmung des Rechteinhabers aufgrund einer (DFG geförderten) Allianz- bzw. Nationallizenz frei zugänglich. This publication is with permission of the rights owner freely accessible due to an Alliance licence and a national licence (funded by the DFG, German Research Foundation) respectively.
License: In Copyright In Copyright
Appears in Collections:Publications with fulltext

Files in This Item:
File Description SizeFormat
095441105x69015.pdfVerlags-PDF434,75 kBAdobe PDFThumbnail
View/Open
Show full item record

Google ScholarTM

Check

Note about this record

Export

Items in TORE are protected by copyright, with all rights reserved, unless otherwise indicated.