Please use this identifier to cite or link to this item: https://doi.org/10.15480/882.1844
DC FieldValueLanguage
dc.contributor.authorSedlacik, Jan-
dc.contributor.authorFrölich, Andreas M. J.-
dc.contributor.authorSpallek, Johanna-
dc.contributor.authorForkert, Nils Daniel-
dc.contributor.authorFaizy, Tobias Djamsched-
dc.contributor.authorWerner, Franziska-
dc.contributor.authorKnopp, Tobias-
dc.contributor.authorKrause, Dieter-
dc.contributor.authorFiehler, Jens-
dc.contributor.authorBuhk, Jan-Hendrik-
dc.contributor.editorSznitman, Josuéde_DE
dc.date.accessioned2018-11-14T12:47:25Z-
dc.date.available2018-11-14T12:47:25Z-
dc.date.issued2016-08-05-
dc.identifier.citationPloS one 8 (11): e0160097- (2016)de_DE
dc.identifier.issn1932-6203de_DE
dc.identifier.urihttp://tubdok.tub.tuhh.de/handle/11420/1847-
dc.description.abstractThe purpose of this work was to demonstrate the capability of magnetic particle imaging (MPI) to assess the hemodynamics in a realistic 3D aneurysm model obtained by additive manufacturing. MPI was compared with magnetic resonance imaging (MRI) and dynamic digital subtraction angiography (DSA).en
dc.language.isoende_DE
dc.publisherPLOSde_DE
dc.relation.ispartofPLOS ONEde_DE
dc.rightsinfo:eu-repo/semantics/openAccess-
dc.subjectAneurysmde_DE
dc.subjectContrast Mediade_DE
dc.subjectHemodynamicsde_DE
dc.subjectHumansde_DE
dc.subjectAngiography, Digital Subtractionde_DE
dc.subjectMagnetic Resonance Imagingde_DE
dc.subjectModels, Biologicalde_DE
dc.subject.ddc600: Technikde_DE
dc.subject.ddc610: Medizinde_DE
dc.titleMagnetic particle imaging for high temporal resolution assessment of aneurysm hemodynamicsde_DE
dc.typeArticlede_DE
dc.identifier.urnurn:nbn:de:gbv:830-882.023273-
dc.identifier.doi10.15480/882.1844-
dc.type.diniarticle-
dc.subject.ddccode610-
dc.subject.ddccode600-
dcterms.DCMITypeText-
tuhh.identifier.urnurn:nbn:de:gbv:830-882.023273de_DE
tuhh.oai.showtrue-
dc.identifier.hdl11420/1847-
tuhh.abstract.englishThe purpose of this work was to demonstrate the capability of magnetic particle imaging (MPI) to assess the hemodynamics in a realistic 3D aneurysm model obtained by additive manufacturing. MPI was compared with magnetic resonance imaging (MRI) and dynamic digital subtraction angiography (DSA).de_DE
tuhh.publisher.doi10.1371/journal.pone.0160097-
tuhh.publication.instituteProduktentwicklung und Konstruktionstechnik M-17de_DE
tuhh.publication.instituteBiomedizinische Bildgebung E-5de_DE
tuhh.identifier.doi10.15480/882.1844-
tuhh.type.opus(wissenschaftlicher) Artikel-
tuhh.institute.germanBiomedizinische Bildgebung E-5de
tuhh.institute.englishBiomedizinische Bildgebung E-5de_DE
tuhh.gvk.hasppnfalse-
openaire.rightsinfo:eu-repo/semantics/openAccessde_DE
dc.type.driverarticle-
dc.rights.ccbyde_DE
dc.rights.ccversion4.0de_DE
dc.type.casraiJournal Article-
tuhh.container.issue8de_DE
tuhh.container.volume11de_DE
tuhh.container.startpageArt.-Nr. 0160097de_DE
dc.rights.nationallicensefalsede_DE
item.grantfulltextopen-
item.creatorGNDSedlacik, Jan-
item.creatorGNDFrölich, Andreas M. J.-
item.creatorGNDSpallek, Johanna-
item.creatorGNDForkert, Nils Daniel-
item.creatorGNDFaizy, Tobias Djamsched-
item.creatorGNDWerner, Franziska-
item.creatorGNDKnopp, Tobias-
item.creatorGNDKrause, Dieter-
item.creatorGNDFiehler, Jens-
item.creatorGNDBuhk, Jan-Hendrik-
item.languageiso639-1other-
item.fulltextWith Fulltext-
item.creatorOrcidSedlacik, Jan-
item.creatorOrcidFrölich, Andreas M. J.-
item.creatorOrcidSpallek, Johanna-
item.creatorOrcidForkert, Nils Daniel-
item.creatorOrcidFaizy, Tobias Djamsched-
item.creatorOrcidWerner, Franziska-
item.creatorOrcidKnopp, Tobias-
item.creatorOrcidKrause, Dieter-
item.creatorOrcidFiehler, Jens-
item.creatorOrcidBuhk, Jan-Hendrik-
crisitem.author.deptProduktentwicklung und Konstruktionstechnik M-17-
crisitem.author.deptBiomedizinische Bildgebung E-5-
crisitem.author.deptBiomedizinische Bildgebung E-5-
crisitem.author.deptProduktentwicklung und Konstruktionstechnik M-17-
crisitem.author.orcid0000-0002-4387-4504-
crisitem.author.orcid0000-0002-1589-8517-
crisitem.author.orcid0000-0002-1253-1699-
crisitem.author.orcid0000-0002-8003-6446-
crisitem.author.parentorgStudiendekanat Maschinenbau-
crisitem.author.parentorgStudiendekanat Elektrotechnik, Informatik und Mathematik-
crisitem.author.parentorgStudiendekanat Elektrotechnik, Informatik und Mathematik-
crisitem.author.parentorgStudiendekanat Maschinenbau-
Appears in Collections:Publications (tub.dok)
Files in This Item:
File Description SizeFormat
journal.pone.0160097.pdfVerlags-PDF2,61 MBAdobe PDFThumbnail
View/Open
Show simple item record

Page view(s)

33
Last Week
1
Last month
6
checked on Jul 20, 2019

Download(s)

52
checked on Jul 20, 2019

Google ScholarTM

Check

Export

This item is licensed under a Creative Commons License Creative Commons