DC FieldValueLanguage
dc.contributor.authorMesser-Hannemann, Philipp-
dc.contributor.authorBätz, Johanna-
dc.contributor.authorLampe, Frank-
dc.contributor.authorKlein, Anke-
dc.contributor.authorPüschel, Klaus-
dc.contributor.authorCampbell, Graeme Michael-
dc.contributor.authorMorlock, Michael-
dc.date.accessioned2019-04-04T09:32:18Z-
dc.date.available2019-04-04T09:32:18Z-
dc.date.issued2019-03-20-
dc.identifier.citationClinical biomechanics (Bristol, Avon) (63): 185-192 (2019-03-20)de_DE
dc.identifier.issn0268-0033de_DE
dc.identifier.urihttp://hdl.handle.net/11420/2257-
dc.description.abstractReaming of the acetabular cavity and cup implantation directly influence the hip rotation center and contact area between implant and bone. Previous studies have reported on an altered rotation center after total hip arthroplasty, but have not studied the influence of reaming and cup implantation separately. Aim of this study was therefore to analyze the individual influence of acetabular reaming and subsequent cup implantation on the rotation center and how this influences the contact conditions at the bone-implant interface.en
dc.language.isoende_DE
dc.relation.ispartofClinical biomechanics (Bristol, Avon)de_DE
dc.subjectCavity preparationde_DE
dc.subjectContact conditionde_DE
dc.subjectCup implantationde_DE
dc.subjectHip arthroplastyde_DE
dc.subjectPress-fitde_DE
dc.subjectRotation centerde_DE
dc.titleThe influence of cavity preparation and press-fit cup implantation on restoring the hip rotation centerde_DE
dc.typeArticlede_DE
dc.type.diniarticle-
dcterms.DCMITypeText-
tuhh.abstract.englishReaming of the acetabular cavity and cup implantation directly influence the hip rotation center and contact area between implant and bone. Previous studies have reported on an altered rotation center after total hip arthroplasty, but have not studied the influence of reaming and cup implantation separately. Aim of this study was therefore to analyze the individual influence of acetabular reaming and subsequent cup implantation on the rotation center and how this influences the contact conditions at the bone-implant interface.de_DE
tuhh.publisher.doi10.1016/j.clinbiomech.2019.03.006-
tuhh.publication.instituteBiomechanik M-3de_DE
tuhh.type.opus(wissenschaftlicher) Artikel-
tuhh.institute.germanBiomechanik M-3de
tuhh.institute.englishBiomechanik M-3de_DE
tuhh.gvk.hasppnfalse-
dc.type.driverarticle-
dc.type.casraiJournal Article-
tuhh.container.volume63de_DE
tuhh.container.startpage185de_DE
tuhh.container.endpage192de_DE
item.fulltextNo Fulltext-
item.openairecristypehttp://purl.org/coar/resource_type/c_6501-
item.creatorOrcidMesser-Hannemann, Philipp-
item.creatorOrcidBätz, Johanna-
item.creatorOrcidLampe, Frank-
item.creatorOrcidKlein, Anke-
item.creatorOrcidPüschel, Klaus-
item.creatorOrcidCampbell, Graeme Michael-
item.creatorOrcidMorlock, Michael-
item.languageiso639-1en-
item.cerifentitytypePublications-
item.openairetypeArticle-
item.grantfulltextnone-
item.creatorGNDMesser-Hannemann, Philipp-
item.creatorGNDBätz, Johanna-
item.creatorGNDLampe, Frank-
item.creatorGNDKlein, Anke-
item.creatorGNDPüschel, Klaus-
item.creatorGNDCampbell, Graeme Michael-
item.creatorGNDMorlock, Michael-
crisitem.author.deptBiomechanik M-3-
crisitem.author.deptBiomechanik M-3-
crisitem.author.deptBiomechanik M-3-
crisitem.author.orcid0000-0003-4466-5971-
crisitem.author.orcid0000-0002-5330-2454-
crisitem.author.parentorgStudiendekanat Maschinenbau-
crisitem.author.parentorgStudiendekanat Maschinenbau-
crisitem.author.parentorgStudiendekanat Maschinenbau-
Appears in Collections:Publications without fulltext
Show simple item record

Page view(s)

131
Last Week
0
Last month
2
checked on Dec 3, 2020

Google ScholarTM

Check

Add Files to Item

Note about this record

Export

Items in TORE are protected by copyright, with all rights reserved, unless otherwise indicated.