Please use this identifier to cite or link to this item: https://doi.org/10.15480/882.2363
DC FieldValueLanguage
dc.contributor.authorMesser-Hannemann, Philipp-
dc.contributor.authorCampbell, Graeme Michael-
dc.contributor.authorMorlock, Michael-
dc.date.accessioned2019-08-08T09:00:43Z-
dc.date.available2019-08-08T09:00:43Z-
dc.date.issued2019-07-13-
dc.identifier.citationClinical Biomechanics (69): 96-103 (2019-10)de_DE
dc.identifier.issn1879-1271de_DE
dc.identifier.urihttp://hdl.handle.net/11420/3058-
dc.description.abstractBackground: Deformation of acetabular cups when press-fitted into an undersized cavity is inevitable due to the inhomogeneous stiffness of acetabular bone. Thinner cups or screw holes might increase the risk of high cup deformation. The aim of this study was to examine the influence of cup design and liner assembly on the deformation response during cup implantation. Methods: Acetabular cups with different designs were implanted into polyurethane foam models simulating the anatomical situation with nominal press-fits of 1mm and without nominal press-fits (line-to-line). Deformations were determined using a tactile coordinate measuring machine. A 3D laser scanner was used to determine the contact conditions at the cup-cavity interface. Polyethylene and ceramic liners were assembled to the implanted cups and the influence of the insertion on the deformation response evaluated. Fixation strength of the cups was determined by push-out testing. Findings: Cup deformation increased with smaller wall thickness (P < 0.037) and screw holes (P < 0.001). Insertion of ceramic liners reduced the deformation (P < 0.001), whereas polyethylene liners adapted to the deformation of the implanted cups (P > 0.999). Thin-walled cups exhibited a higher fixation strength for similar implantation forces (P = 0.011). Interpretation: Thin-walled cups achieved higher fixation strengths and might be more bone-preserving. However, in combination with screw holes and high press-fit levels, wall thickness should be considered carefully to avoid excessive cup deformations leading to potential complications during liner assembly. Line-to-line insertion of thin-walled cups should be accompanied with a rough surface coating to minimize the loss of fixation strength due to the low press-fit fixation.en
dc.language.isoende_DE
dc.publisherElsevier Sciencede_DE
dc.relation.ispartofClinical biomechanicsde_DE
dc.subjecthip arthroplastyde_DE
dc.subjectpress-fitde_DE
dc.subjectcup deformationde_DE
dc.subjectprimary stabilityde_DE
dc.subjectcontact conditionde_DE
dc.subject.ddc570: Biowissenschaften, Biologiede_DE
dc.subject.ddc610: Medizinde_DE
dc.titleDeformation of acetabular press-fit cups: influence of design and surgical factorsde_DE
dc.typeArticlede_DE
dc.identifier.urnurn:nbn:de:gbv:830-882.045033-
dc.identifier.doi10.15480/882.2363-
dc.type.diniarticle-
dc.subject.ddccode570-
dc.subject.ddccode610-
dcterms.DCMITypeText-
tuhh.identifier.urnurn:nbn:de:gbv:830-882.045033-
tuhh.oai.showtruede_DE
tuhh.abstract.englishBackground: Deformation of acetabular cups when press-fitted into an undersized cavity is inevitable due to the inhomogeneous stiffness of acetabular bone. Thinner cups or screw holes might increase the risk of high cup deformation. The aim of this study was to examine the influence of cup design and liner assembly on the deformation response during cup implantation. Methods: Acetabular cups with different designs were implanted into polyurethane foam models simulating the anatomical situation with nominal press-fits of 1mm and without nominal press-fits (line-to-line). Deformations were determined using a tactile coordinate measuring machine. A 3D laser scanner was used to determine the contact conditions at the cup-cavity interface. Polyethylene and ceramic liners were assembled to the implanted cups and the influence of the insertion on the deformation response evaluated. Fixation strength of the cups was determined by push-out testing. Findings: Cup deformation increased with smaller wall thickness (P < 0.037) and screw holes (P < 0.001). Insertion of ceramic liners reduced the deformation (P < 0.001), whereas polyethylene liners adapted to the deformation of the implanted cups (P > 0.999). Thin-walled cups exhibited a higher fixation strength for similar implantation forces (P = 0.011). Interpretation: Thin-walled cups achieved higher fixation strengths and might be more bone-preserving. However, in combination with screw holes and high press-fit levels, wall thickness should be considered carefully to avoid excessive cup deformations leading to potential complications during liner assembly. Line-to-line insertion of thin-walled cups should be accompanied with a rough surface coating to minimize the loss of fixation strength due to the low press-fit fixation.de_DE
tuhh.publisher.doi10.1016/j.clinbiomech.2019.07.014-
tuhh.publication.instituteBiomechanik M-3de_DE
tuhh.identifier.doi10.15480/882.2363-
tuhh.type.opus(wissenschaftlicher) Artikel-
tuhh.institute.germanBiomechanik M-3de
tuhh.institute.englishBiomechanik M-3de_DE
tuhh.gvk.hasppnfalse-
dc.type.driverarticle-
dc.rights.cchttps://creativecommons.org/licenses/by-nc-nd/4.0/de_DE
dc.type.casraiJournal Article-
tuhh.container.volume69de_DE
tuhh.container.startpage96de_DE
tuhh.container.endpage103de_DE
dc.rights.nationallicensefalsede_DE
item.creatorGNDMesser-Hannemann, Philipp-
item.creatorGNDCampbell, Graeme Michael-
item.creatorGNDMorlock, Michael-
item.fulltextWith Fulltext-
item.languageiso639-1other-
item.creatorOrcidMesser-Hannemann, Philipp-
item.creatorOrcidCampbell, Graeme Michael-
item.creatorOrcidMorlock, Michael-
item.grantfulltextembargo_20201001-
crisitem.author.deptBiomechanik M-3-
crisitem.author.deptBiomechanik M-3-
crisitem.author.deptBiomechanik M-3-
crisitem.author.orcid0000-0002-5330-2454-
crisitem.author.parentorgStudiendekanat Maschinenbau-
crisitem.author.parentorgStudiendekanat Maschinenbau-
crisitem.author.parentorgStudiendekanat Maschinenbau-
Appears in Collections:Publications (tub.dok)
Files in This Item:
File Description SizeFormat
Messer-Hannemann P 2019 ClinBio Deformation of acetabular press-fit cups - Influence of design and surgical factors.pdfaccepted manuscript1,66 MBAdobe PDFEmbargoed until October 1, 2020    Request a copy
Show simple item record

Page view(s)

113
checked on Aug 19, 2019

Download(s)

10
checked on Aug 19, 2019

Google ScholarTM

Check

Export

This item is licensed under a Creative Commons License Creative Commons