Pham, Minh NhatMinh NhatPhamAkpinar, RidvanRidvanAkpinarJacob, ArneArneJacob2020-02-122020-02-122016-04-27GeMiC 2016 - 2016 German Microwave Conference: 7461642 (2016-04-27)http://hdl.handle.net/11420/4899On-line calibration systems with near-field probes are an attractive approach for large-size DBF arrays. In order to improve the calibration accuracy, a model of the coupling between the receiver patch and the calibration monopole probe is developed further in this contribution. A Fourier-based approximation of the radiation characteristic of the patch is proposed as a compromise between accuracy and computational effort. A planar array is built to validate the proposed concept. A phase error of 1.5° and an amplitude deviation of 0.8 dB are achieved in the experiments.enProbe-receiver coupling in external calibration systemsConference Paper10.1109/GEMIC.2016.7461642Other