Options
Acronym
MFIA-5M
Name
Zurich Instruments MFIA 5 MHz Impedance Analyzer
Manufacturer
Zurich Instruments AG
Description
Impedance Analyzer:

General:
Dimensions: 28.3 x 23.2 x 10.2 cm; 11.1 x 9.2 x 4 inch
Weight: 3.8 kg; 8.4 lbs
Power supply: AC: 100 to 240 V; DC: 12 V, 2 A
Interface: USB 2.0, LAN 1GbE

Basic specifications:
Frequency range: 1 mHz to 5 MHz
Frequency resolution: 1 µHz
Basic accuracy: 0.05%
Basic temp. stability: 200 ppm/K
Test signal level: 0 V to 2.1 Vrms; incl. monitoring
Demodulator bandwidth: 276 µHz to 206 kHz
DC bias signal level: 2T: ±10 V, 4T: ±3 V
Compensation: SO, SOL, LLL, SL, L, OL

Measurement parameters, range and typ. accuracy:
Impedance Z: 1 mΩ to 1 TΩ, up to 0.05%
Admittance Y: 1 pS to 1 kS, up to 0.05%
Voltage V: 0 V to 3 V, 1%
Current I: 0 mA to 10 mA, 2%
Phases: ΘZ, ΘY, ΘV, ΘI ±180 deg, 10 µdeg res.
Resistance RS, RP1: 1 mΩ to 1 TΩ, max(10 µOhm, 0.05%)
Capacitance CS, CP1: 10 fF to 1 F, max(10 fF, 0.05%)
Inductance LS, LP1: 100 nH to 1 H, max(10 nH, 0.05%)
DC Resistance RDC: 1 mΩ to 10 GΩ, 2%
Reactance X: 1 mΩ to 1 TΩ, 0.05%
Conductance G, Susceptance B: 1 nS to 1 kS, max(100 nS, 0.05%)
Loss coefficient D: 10-4 to 10'000
Q factor: 10-4 to 10'000

LabOne Sweeper:
Sweep parameters: Frequency, test signal amplitude, bias voltage, etc.
Sweep points: 2 to 100'000
Sweep resolution: Arbitrary, defined by start value, stop value, number of sweep points
Display parameters: ZX, ZY, Z, ZΘ, VX, VY, VR, VΘ, IX, IY, IR, IΘ, model parameter 1/2, frequency, auxiliary input
Display options: Single plot, dual plot (e.g., Bode plot), multi-trace
Application modes: Impedance, frequency response analyzer, 3-omega, etc.
Sweep modes: Sequential, binary, bidirectional, reverse
Sweep step modes: Linear, logarithmic
Sweep speed: 20 ms/pt for f > 10 kHz

Additional tools and features:
LabOne toolset: Numerical, FFT Spectrum Analyzer, Plotter, SW Trigger, Scope
APIs: C, .NET, MATLAB, LabVIEW, Python
Modes: 2-terminal, 4-terminal
Confidence Indicator: Suppression, compensation, overflow, underflow
Input range control: Auto, impedance, manual
Test signal amplitude: Auto, manual
Bandwidth control: Auto, manual
Replacement circuit models: Rp||Cp, Rs+Cs, Rs+Ls, G-B, D-Cs, Q-Cs, D-Ls, Q-Ls
DCR measurements: Yes
Test fixture compatibility: Yes

Additional functionalities:
- Lock-in amplifier
- high resolution signal generator
- high resolution ADC
- high resolution digital oscilloscope

Links to further documentation:
https://www.zhinst.com/ch/de/mfli-and-mfia-specification
https://www.zhinst.com/sites/default/files/documents/2023-03/zi_mfia_leaflet_de.pdf
https://docs.zhinst.com/mfia_user_manual/?_gl=1*1lybyg4*_gcl_au*MjA5Mjg3MDAzNS4xNzM5MTg2NzMz
Website
https://www.zhinst.com/ch/de/products/mfia-impedance-analyzer
DOI
10.15480/882.15170
Classification
6490 -- Messgeräte (elektrische und elektronische), sonstige
Owner Organisation
Mechatronik im Maschinenbau M-4  
Contact Person
Kähler, Dennis  
Available since
2023
Access
Shared Access
TUHH
Weiterführende Links
  • Contact
  • Send Feedback
  • Cookie settings
  • Privacy policy
  • Impress
DSpace Software

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science
Design by effective webwork GmbH

  • Deutsche NationalbibliothekDeutsche Nationalbibliothek
  • ORCiD Member OrganizationORCiD Member Organization
  • DataCiteDataCite
  • Re3DataRe3Data
  • OpenDOAROpenDOAR
  • OpenAireOpenAire
  • BASE Bielefeld Academic Search EngineBASE Bielefeld Academic Search Engine
Feedback