Robust multivariable control design for HVDC back to back schemes

Publikationstyp
Journal Article
Date Issued
2003-11
Sprache
English
Author(s)
Aten, Martin  
Werner, Herbert  
Institut
Regelungstechnik E-14  
TORE-URI
http://hdl.handle.net/11420/14933
Journal
IEE proceedings / Generation, transmission and distribution  
Volume
150
Issue
6
Start Page
761
End Page
767
Citation
IEE Proceedings: Generation, Transmission and Distribution 150 (6): 761-767 (2003-11-01)
Publisher DOI
10.1049/ip-gtd:20030724
Scopus ID
2-s2.0-0346149860
Publisher
IET
A robust multivariable control design procedure for HVDC back-to-back schemes is presented. HVDC links are commonly controlled with a decentralised structure, whereby in normal operation the rectifier may track direct current and the inverter may track direct voltage, firing angle or extinction angle. In the case of a back-to-back HVDC link the measurements of control variables of both sides are physically close, hence it is possible to apply a true multivariable controller whereby current and voltage are controlled by rectifier and inverter together. H-infinity control theory is used for a systematic tuning procedure which incorporates robustness against uncertainty in the short-circuit levels of both rectifier and inverter side AC systems. The linear control transfer functions for rectifier and inverter controllers are arrived at simultaneously thereby removing iterative design steps to find the best combination of control parameters for both rectifier and inverter controllers. The decoupling effect resulting from the multivariable controller structure reduces the interaction between tracking of direct current and direct voltage. It is verified by nonlinear EMTDC simulation that the designed controller is robust and can contribute to good fault recovery when integrated with other control loops and nonlinear control functions as implemented in manufactured controls.
DDC Class
600: Technik
620: Ingenieurwissenschaften
TUHH
Weiterführende Links
  • Contact
  • Send Feedback
  • Cookie settings
  • Privacy policy
  • Impress
DSpace Software

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science
Design by effective webwork GmbH

  • Deutsche NationalbibliothekDeutsche Nationalbibliothek
  • ORCiD Member OrganizationORCiD Member Organization
  • DataCiteDataCite
  • Re3DataRe3Data
  • OpenDOAROpenDOAR
  • OpenAireOpenAire
  • BASE Bielefeld Academic Search EngineBASE Bielefeld Academic Search Engine
Feedback