  4. The influence of contact conditions and micromotions on the fretting behavior of modular titanium alloy taper connections
 
Options

The influence of contact conditions and micromotions on the fretting behavior of modular titanium alloy taper connections

Publikationstyp
Journal Article
Date Issued
2013-08-30
Sprache
English
Author(s)
Baxmann, Marc  
Jauch, Sabrina Yvonne  
Schilling, Christoph  
Blömer, Wilhelm  
Grupp, Thomas M.  
Morlock, Michael  
Institut
Biomechanik M-3  
TORE-URI
http://hdl.handle.net/11420/6859
Journal
Medical engineering & physics  
Volume
35
Issue
5
Start Page
676
End Page
683
Citation
Medical Engineering and Physics 5 (35): 676-683 (2013)
Publisher DOI
10.1016/j.medengphy.2012.07.013
Scopus ID
2-s2.0-84877606482
Publisher
Elsevier Science
Modularity of femoral stems and neck components has become a more frequently used tool for an optimized restoration of the hip joint center and improvement of patient biomechanics. The additional taper interface increases the risk of mechanical failure due to fretting and crevice corrosion. Several failures of titanium alloy neck adapters have been documented in case-reports. An experimental fretting device was developed in this study to systematically investigate the effect of micromotion and contact pressure on fretting damage in contact situations similar to taper interfaces of modular hip prostheses under cyclic loading representative of in vivo load conditions. As a first application, the fretting behavior of Ti-6Al-4V titanium alloy components was investigated. Micromotions were varied between 10μm and 50μm, maximum contact pressures between 400 and 860N/mm2. All modes of fretting damage were observed: Fretting wear was found for high micromotions in combination with low contact pressures. Fretting fatigue occurred with reduced movement or increased contact pressures. With small micromotions or high normal pressures, low fretting damage was observed. The developed device can be used to evaluate taper design (and especially contact geometry) as well as different materials prior to clinical use. © 2012 IPEM.
Subjects
Fretting
Modular hip
Stem-neck interface
Titanium alloy
DDC Class
610: Medizin
TUHH
Weiterführende Links
  • Contact
  • Send Feedback
  • Cookie settings
  • Privacy policy
  • Impress
DSpace Software

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science
Design by effective webwork GmbH

  • Deutsche NationalbibliothekDeutsche Nationalbibliothek
  • ORCiD Member OrganizationORCiD Member Organization
  • DataCiteDataCite
  • Re3DataRe3Data
  • OpenDOAROpenDOAR
  • OpenAireOpenAire
  • BASE Bielefeld Academic Search EngineBASE Bielefeld Academic Search Engine
Feedback