TUHH Open Research
Help
New user? Click here to register.Have you forgotten your password?
Communities & Collections
Publications
Research Data
People
Institutions
Projects
  1. Home
  2. Publications
  3. Publications
  4. Automated non-contact respiratory rate monitoring of neonates based on synchronous evaluation of a 3D time-of-flight camera and a microwave interferometric radar sensor

Automated non-contact respiratory rate monitoring of neonates based on synchronous evaluation of a 3D time-of-flight camera and a microwave interferometric radar sensor

Citation Link: https://doi.org/10.15480/882.3468
Publikationstyp
Journal Article
Date Issued
2021-05-01
Sprache
English
Author(s)
Gleichauf, Johanna
Herrmann, Sven
Hennemann, Lukas
Krauss, Hannes
Nitschke, Janina
Renner, Philipp
Niebler, Christine
Kölpin, Alexander
Institut
Hochfrequenztechnik E-3
TORE-DOI
10.15480/882.3468
TORE-URI
http://hdl.handle.net/11420/9369
Journal
Sensors
Volume
21
Issue
9
Article Number
2959
Citation
Sensors 21 (9): 2959 (2021-05-01)
Publisher DOI
10.3390/s21092959
Scopus ID
2-s2.0-85104548388
Publisher
Multidisciplinary Digital Publishing Institute (MDPI)
This paper introduces an automatic non-contact monitoring method based on the synchronous evaluation of a 3D time-of-flight (ToF) camera and a microwave interferometric radar sensor for measuring the respiratory rate of neonates. The current monitoring on the Neonatal Intensive Care Unit (NICU) has several issues which can cause pressure marks, skin irritations and eczema. To minimize these risks, a non-contact system made up of a 3D time-of-flight camera and a microwave interferometric radar sensor is presented. The 3D time-of-flight camera delivers 3D point clouds which can be used to calculate the change in distance of the moving chest and from it the respiratory rate. The disadvantage of the ToF camera is that the heartbeat cannot be determined. The microwave interferometric radar sensor determines the change in displacement caused by the respiration and is even capable of measuring the small superimposed movements due to the heartbeat. The radar sensor is very sensitive towards movement artifacts due to, e.g., the baby moving its arms. To allow a robust vital parameter detection the data of both sensors was evaluated synchronously. In this publication, we focus on the first step: determining the respiratory rate. After all processing steps, the respiratory rate determined by the radar sensor was compared to the value received from the 3D time-of-flight camera. The method was validated against our gold standard: a self-developed neonatal simulation system which can simulate different breathing patterns. In this paper, we show that we are the first to determine the respiratory rate by evaluating the data of an interferometric microwave radar sensor and a ToF camera synchronously. Our system delivers very precise breaths per minute (BPM) values within the norm range of 20–60 BPM with a maximum difference of 3 BPM (for the ToF camera itself at 30 BPM in "normal" mode). Especially in lower respiratory rate regions, i.e., 5 and 10 BPM, the synchronous evaluation is required to compensate the drawbacks of the ToF camera. In the norm range, the ToF camera performs slightly better than the radar sensor.
Subjects
non-contact monitoring
neonates
synchronous evaluation
respiratory rate
DDC Class
600: Technik
620: Ingenieurwissenschaften
Lizenz
https://creativecommons.org/licenses/by/4.0/
Publication version
publishedVersion
Loading...
Thumbnail Image
Download
Name

sensors-21-02959.pdf

Size

17.71 MB

Format

Adobe PDF

TUHH
Weiterführende Links
  • Contact
  • Send Feedback
  • Cookie settings
  • Privacy policy
  • Impress
DSpace Software

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science
Design by effective webwork GmbH

  • Deutsche NationalbibliothekDeutsche Nationalbibliothek
  • ORCiD Member OrganizationORCiD Member Organization
  • DataCiteDataCite
  • Re3DataRe3Data
  • OpenDOAROpenDOAR
  • OpenAireOpenAire
  • BASE Bielefeld Academic Search EngineBASE Bielefeld Academic Search Engine
Feedback