TUHH Open Research
Help
  • Log In
    New user? Click here to register.Have you forgotten your password?
  • English
  • Deutsch
  • Communities & Collections
  • Publications
  • Research Data
  • People
  • Institutions
  • Projects
  • Statistics
  1. Home
  2. TUHH
  3. Publication References
  4. Hemodynamics in arterial bypass graft anastomoses with varying cuff sizes and proximal flow paths: a fluid–structure interaction study
 
Options

Hemodynamics in arterial bypass graft anastomoses with varying cuff sizes and proximal flow paths: a fluid–structure interaction study

Publikationstyp
Journal Article
Date Issued
2024
Sprache
English
Author(s)
Bletsos, Georgios  
Fluiddynamik und Schiffstheorie M-8  
Rung, Thomas  orcid-logo
Fluiddynamik und Schiffstheorie M-8  
Radtke, Lars  
Konstruktion und Festigkeit von Schiffen M-10  
TORE-URI
https://hdl.handle.net/11420/47635
Journal
Computer methods in biomechanics and biomedical engineering  
Volume
28
Issue
7
Start Page
1066
End Page
1085
Citation
Computer Methods in Biomechanics and Biomedical Engineering 28 (7): 1066-1085 (2025)
Publisher DOI
10.1080/10255842.2024.2310747
Scopus ID
2-s2.0-85184461377
Publisher
Taylor and Francis
ISSN
10255842
This article investigates the effect of the cuff size of arterial bypass grafts and the flow conditions on the hemodynamics in the anastomosis (connection) to the artery, using numerical simulations. We consider a fluid-structure interaction problem which is solved based on a partitioned scheme. Additionally, we employ computational fluid dynamics to investigate the effect of a rigid wall assumption. The work focuses on clinically relevant hemodynamic quantities associated with the development of intimal hyperplasia. We also include a model for the prediction of hemolysis into the simulation. The results show that even minor changes of the cuff size can result into significant differences in the corresponding quantities of interest. The importance of the inflow path is shown to be lower than that of the cuff size. The usually employed rigid wall assumption is found to be adequate to address wall shear stress oscillations but falls short on predicting maximum and minimum wall shear stress-related quantities of interest.
Subjects
bypass-graft
fluid–structure interaction
Hemodynamics
hemolysis
oscillatory shear index
DDC Class
600: Technology
TUHH
Weiterführende Links
  • Contact
  • Send Feedback
  • Cookie settings
  • Privacy policy
  • Impress
DSpace Software

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science
Design by effective webwork GmbH

  • Deutsche NationalbibliothekDeutsche Nationalbibliothek
  • ORCiD Member OrganizationORCiD Member Organization
  • DataCiteDataCite
  • Re3DataRe3Data
  • OpenDOAROpenDOAR
  • OpenAireOpenAire
  • BASE Bielefeld Academic Search EngineBASE Bielefeld Academic Search Engine
Feedback