TUHH Open Research
Help
New user? Click here to register.Have you forgotten your password?
Communities & Collections
Publications
Research Data
People
Institutions
Projects
  1. Home
  2. Publications
  3. Publications
  4. Distal cortical notching significantly decreases tibial stability following tibial tubercle osteotomy: an in vitro porcine biomechanical study

Distal cortical notching significantly decreases tibial stability following tibial tubercle osteotomy: an in vitro porcine biomechanical study

Citation Link: https://doi.org/10.15480/882.17682
Publikationstyp
Journal Article
Date Issued
2026-07-17
Sprache
English
Author(s)
Senkbeil, Eiken
Sellenschloh, Kay
Biomechanik M-3
Frosch, Karl-Heinz
Krause, Matthias
Checa Esteban, Sara
Biomechanik M-3
Frings, Jannik
TORE-DOI
10.15480/882.17682
TORE-URI
https://hdl.handle.net/11420/64117
Journal
Journal of Experimental Orthopaedics
Volume
13
Issue
3
Article Number
e70858
Citation
Journal of Experimental Orthopaedics 13 (3): e70858 (2026)
Publisher DOI
10.1002/jeo2.70858
Scopus ID
2-s2.0-105044815796
Publisher
Wiley
Purpose: Distalizing tibial tubercle osteotomy (dTTO) is an effective treatment for patella alta, yet complications can be severe. This study evaluates the biomechanical effects of distal cut orientation on tibial fracture risk. It was hypothesised that orthogonal cutting and cortical notching reduce tibial stability. Methods: A total of 61 porcine tibiae were tested in three setups. Four distal cut orientations were compared in a load-to-failure analysis (n = 32): oblique (Obl), orthogonal without notch (Orth), orthogonal 2-mm notch (Orth2), orthogonal 4-mm notch (Orth4) (each n = 8). Cyclic loading was evaluated in Obl, Orth and Orth2 (n = 17), followed by comparison of plate versus (2-hole one-third tubular plate) 3.5-mm screw fixation in Orth2 specimens (n = 12). Specimens were embedded in PMMA and axially loaded (MTS Bionix 358). Load-to-failure, stiffness and cycles until failure were recorded. Residual tibial thickness was measured. Linear regression analysed the relationship between residual thickness and failure load. Statistical analysis included t-tests and ANOVA (α = 0.05). Results: Obl showed the highest failure load (784.5 N ± 118.3), although the difference compared to Orth (538.8 N ± 229.5, p = 0.087) did not reach statistical significance. Notching significantly reduced load-to-failure (2-mm: 294.0 N ± 91.8; 4 mm: 274.6 N ± 96.5). In cyclic testing, Obl withstood most cycles until failure (5894 ± 2187) compared to Orth (3142 ± 808; p = 0.004), while Orth2 failed sooner (1400 ± 530, all p < 0.005). Osteosynthesis techniques did not affect failure load (p = 0.802). Stiffness and residual tibial thickness were comparable. Distal tibial thickness was associated with failure load in all groups (all p < 0.05). Conclusion: In this porcine model, cortical notching significantly reduced tibial stability and should be avoided during TTO. Oblique distal cuts demonstrated greater resistance to cyclic loading, while no significant difference was observed in static load-to-failure. Osteosynthesis technique did not affect load-to-failure. Level of Evidence: NA, cadaveric biomechanical study.
Subjects
complication
fracture
instability
osteotomy
patella
patella alta
tibial tubercle transfer
DDC Class
610: Medicine, Health
Lizenz
https://creativecommons.org/licenses/by/4.0/
Publication version
publishedVersion
Loading...
Thumbnail Image
Download
Name

J exp orthop - 2026 - Senkbeil - Distal cortical notching significantly decreases tibial stability following tibial.pdf

Type

Main Article

Size

4.59 MB

Format

Adobe PDF

TUHH
Weiterführende Links
  • Contact
  • Send Feedback
  • Cookie settings
  • Privacy policy
  • Impress
DSpace Software

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science
Design by effective webwork GmbH

  • Deutsche NationalbibliothekDeutsche Nationalbibliothek
  • ORCiD Member OrganizationORCiD Member Organization
  • DataCiteDataCite
  • Re3DataRe3Data
  • OpenDOAROpenDOAR
  • OpenAireOpenAire
  • BASE Bielefeld Academic Search EngineBASE Bielefeld Academic Search Engine
Feedback