TUHH Open Research
Help
  • Log In
    New user? Click here to register.Have you forgotten your password?
  • English
  • Deutsch
  • Communities & Collections
  • Publications
  • Research Data
  • People
  • Institutions
  • Projects
  • Statistics
  1. Home
  2. TUHH
  3. Publications
  4. Assembly force and taper angle difference influence the relative motion at the stem-neck interface of bi-modular hip prostheses
 
Options

Assembly force and taper angle difference influence the relative motion at the stem-neck interface of bi-modular hip prostheses

Citation Link: https://doi.org/10.15480/882.1550
Publikationstyp
Journal Article
Date Issued
2016-07
Sprache
English
Author(s)
Haschke, Henning  
Jauch-Matt, Sabrina Y.  
Sellenschloh, Kay  
Huber, Gerd  
Morlock, Michael  
Institut
Biomechanik M-3  
TORE-DOI
10.15480/882.1550
TORE-URI
http://tubdok.tub.tuhh.de/handle/11420/1553
Journal
Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine  
Volume
230
Issue
7
Start Page
690
End Page
699
Citation
Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine 7 (230): pp. 690-699 (2016)
Publisher DOI
10.1177/0954411916648717
Scopus ID
2-s2.0-84973514545
Publisher
Sage Publ.
Bi-modular hip arthroplasty prostheses allow adaptation to the individual patient anatomy and the combination of different materials but introduce an additional interface, which was related lately to current clinical issues. Relative motion at the additional taper interface might increase the overall risk of fretting, corrosion, metallic debris and early failure. The aim of this study was to investigate whether the assembly force influences the relative motion and seating behaviour at the stem-neck interface of a bi-modular hip prosthesis (Metha(®); Aesculap AG, Tuttlingen, Germany) and whether this relation is influenced by the taper angle difference between male and female taper angles. Neck adapters made of titanium (Ti6Al4V) and CoCr (CoCr29Mo) were assembled with a titanium stem using varying assembly forces and mechanically loaded. A contactless eddy current measurement system was used to record the relative motion between prosthesis stem and neck adapter. Higher relative motion was observed for Ti neck adapters compared to the CoCr ones (p < 0.001). Higher assembly forces caused increased seating distances (p < 0.001) and led to significantly reduced relative motion (p = 0.019). Independent of neck material type, prostheses with larger taper angle difference between male and female taper angles exhibited decreased relative motion (p < 0.001). Surgeons should carefully use assembly forces above 4 kN to decrease the amount of relative motion within the taper interface. Maximum assembly forces, however, should be limited to prevent periprosthetic fractures. Manufacturers should optimize taper angle differences to increase the resistance against relative motion.
Subjects
modular prosthesis
assembly force
relative motion
stem–neck interface
taper angle difference
arthroplasty
biomechanical phenomena
humans
materials testing
motion
prosthesis design
prosthesis failure
mechanical stress
titanium
vitallium
hip prosthesis
hip replacement
DDC Class
610: Medizin
Lizenz
http://rightsstatements.org/vocab/InC/1.0/
Loading...
Thumbnail Image
Name

0954411916648717.pdf

Size

3.08 MB

Format

Adobe PDF

TUHH
Weiterführende Links
  • Contact
  • Send Feedback
  • Cookie settings
  • Privacy policy
  • Impress
DSpace Software

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science
Design by effective webwork GmbH

  • Deutsche NationalbibliothekDeutsche Nationalbibliothek
  • ORCiD Member OrganizationORCiD Member Organization
  • DataCiteDataCite
  • Re3DataRe3Data
  • OpenDOAROpenDOAR
  • OpenAireOpenAire
  • BASE Bielefeld Academic Search EngineBASE Bielefeld Academic Search Engine
Feedback