16th European Conference on Composite Materials, ECCM 2014: (2014)
Contribution to Conference
Scopus ID
This experimental study presents a detailed study on the failure mechanisms of a CFRP single-lap shear joint under cyclic loading conditions. The joint consists of two laminate plates and two CFRP fasteners with countersunk heads. Based on the investigations of this experimental work, the failure mechanisms in cyclic loading of the CFRP-fastener can be described. Further test with different parameter configurations show their influence on the failure process of the joint.
Schlagworte
Clamping force
Composite bolted joints
Countersunk head CFRP-fasteners
Fitting tolerance
DDC Class