High accuracy 3D data acquisition using co-registered OCT and kinect

Publikationstyp
Conference Paper
Date Issued
2016-07-02
Sprache
English
Author(s)
Rajput, Omer 
Antoni, Sven-Thomas  
Otte, Christoph  
Saathoff, Thore  
Matthäus, Lars  
Schlaefer, Alexander  
Institut
Medizintechnische Systeme E-1  
TORE-URI
http://hdl.handle.net/11420/3887
Start Page
32
End Page
37
Article Number
7849463
Citation
IEEE International Conference on Multisensor Fusion and Integration for Intelligent Systems: 7849463, 32-37 (2016-07-02)
Contribution to Conference
2016 IEEE lnternational Conference on Multisensor Fusion and Integration for Intelligent Systems, MFI 2016  
Publisher DOI
10.1109/MFI.2016.7849463
Scopus ID
2-s2.0-85015227953
Publisher
IEEE
In many clinical scenarios, the spatial resolution of typical time-of-flight devices is not sufficient. Optical coherence tomography (OCT) presents an interesting high resolution modality with applications in image guided surgery and tissue characterization. However, the small field of view makes scanning larger areas difficult. We therefore consider co-registering a ToF depth camera (Kinect) with its large field-of-view but limited accuracy and OCT with its smaller field-of-view but very high accuracy. We study two approaches to obtain a registration between Kinect and OCT. The first approach is based on a novel marker and a direct registration between the two devices, either with or without using the construction of the novel marker. The second approach uses the marker to obtain a calibration between the OCT and a hexapod (Stewart platform) carrying it, and separate calibration between hexapod and Kinect. We show that the first approach typically results in better registration between Kinect and OCT with translational and rotational errors of (2.25 ± 1.23) mm and (1.54 ± 0.77)°, respectively. Furthermore, we demonstrate the use of the combined system to obtain a high resolution scan of the irregularly shaped surface of a head phantom.
DDC Class
600: Technik
610: Medizin
TUHH
Weiterführende Links
  • Contact
  • Send Feedback
  • Cookie settings
  • Privacy policy
  • Impress
DSpace Software

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science
Design by effective webwork GmbH

  • Deutsche NationalbibliothekDeutsche Nationalbibliothek
  • ORCiD Member OrganizationORCiD Member Organization
  • DataCiteDataCite
  • Re3DataRe3Data
  • OpenDOAROpenDOAR
  • OpenAireOpenAire
  • BASE Bielefeld Academic Search EngineBASE Bielefeld Academic Search Engine
Feedback