TUHH Open Research
Help
  • Log In
    New user? Click here to register.Have you forgotten your password?
  • English
  • Deutsch
  • Communities & Collections
  • Publications
  • Research Data
  • People
  • Institutions
  • Projects
  • Statistics
  1. Home
  2. TUHH
  3. Publication References
  4. MPI as high temporal resolution imaging technique for in vivo bolus tracking of Ferucarbotran in mouse model
 
Options

MPI as high temporal resolution imaging technique for in vivo bolus tracking of Ferucarbotran in mouse model

Publikationstyp
Conference Paper
Date Issued
2016
Sprache
English
Author(s)
Jung, Caroline  
Salamon, Johannes  
Hofmann, Martin  orcid-logo
Kaul, Michael  
Adam, Gerhard  
Ittrich, Harald  
Knopp, Tobias  
Institut
Biomedizinische Bildgebung E-5  
TORE-URI
http://hdl.handle.net/11420/5669
First published in
Progress in Biomedical Optics and Imaging - Proceedings of SPIE  
Number in series
9788
Article Number
97880V
Citation
Progress in Biomedical Optics and Imaging - Proceedings of SPIE (9788): 97880V (2016)
Publisher DOI
10.1117/12.2216660
The goal of this study was to achieve a real time 3D visualisation of the murine cardiovascular system by intravenously injected superparamagnetic nanoparticles using Magnetic particle imaging (MPI). Material and Methods MPI scans of FVB mice were performed using a 3D imaging sequence (1T/m gradient strength, 10mT drive-field strength). A dynamic scan with a temporal resolution of 21.5ms per 3D volume acquisition was performed. 50μl ferucarbotran (Resovist®, Bayer Healthcare AG) were injected into the tail vein after baseline MPI measurements. As MPI delivers no anatomic information, MRI scans at a 7T ClinScan (Bruker) were performed using a T2-weighted 2D TSE sequence. The reconstruction of the MPI data was performed on the MPI console (ParaVision 6.0/MPI, Bruker). Image fusion was done using additional image processing software (Imalytics, Philips). The dynamic information was extracted using custom software developed in the Julia programming environment. Results The combined MRI-MPI measurements were carried out successfully. MPI data clearly demonstrated the passage of the SPIO tracer through the inferior vena cava, the heart and finally the liver. By co-registration with MRI the anatomical regions were identified. Due to the volume frame rate of about 46 volumes per second a signal modulation with the frequency of the heart beat was detectable and a heart beat of 520 beats per minute (bpm) has been assumed. Moreover, the blood flow velocity of approximately 5cm/s in the vena cava has been estimated. Conclusions The high temporal resolution of MPI allows real-time imaging and bolus tracking of intravenous injected nanoparticles and offers a real time tool to assess blood flow velocity.
Subjects
3D real time imaging
Blood flow velocity
Bolus tracking
Magnetic particle imaging
Magnetic resonance imaging
SPIO
TUHH
Weiterführende Links
  • Contact
  • Send Feedback
  • Cookie settings
  • Privacy policy
  • Impress
DSpace Software

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science
Design by effective webwork GmbH

  • Deutsche NationalbibliothekDeutsche Nationalbibliothek
  • ORCiD Member OrganizationORCiD Member Organization
  • DataCiteDataCite
  • Re3DataRe3Data
  • OpenDOAROpenDOAR
  • OpenAireOpenAire
  • BASE Bielefeld Academic Search EngineBASE Bielefeld Academic Search Engine
Feedback