TUHH Open Research
Help
  • Log In
    New user? Click here to register.Have you forgotten your password?
  • English
  • Deutsch
  • Communities & Collections
  • Publications
  • Research Data
  • People
  • Institutions
  • Projects
  • Statistics
  1. Home
  2. TUHH
  3. Publication References
  4. Magnetic Resonance Imaging of Structured Packings: Overcoming Spatial, Signal, and Geometric Challenges
 
Options

Magnetic Resonance Imaging of Structured Packings: Overcoming Spatial, Signal, and Geometric Challenges

Publikationstyp
Conference Presentation
Date Issued
2025-08-21
Sprache
English
Author(s)
Rennebaum, Hannah Sophie  
Prozessbildgebung V-10  
Dobschall, Alina  
Systemverfahrenstechnik V-4  
Benders, Stefan  
Prozessbildgebung V-10  
Skiborowski, Mirko  orcid-logo
Systemverfahrenstechnik V-4  
Penn, Alexander  orcid-logo
Prozessbildgebung V-10  
TORE-URI
https://hdl.handle.net/11420/57909
Citation
18th International Conference on Magnetic Resonance Microscopy, ICMRM 2025
Contribution to Conference
18th International Conference on Magnetic Resonance Microscopy, ICMRM 2025  
Structured packings are widely employed in trickle beds to improve the mass transfer between the liquid and gas phases in absorption and distillation processes. While integral experiments, such as pressure drop measurements and collector experiments, offer overall insights, they lack spatial and temporal detail on liquid distribution. Magnetic Resonance Imaging (MRI) overcomes this by providing resolved flow visualization, though its application is challenged by low liquid content, the need for high temporal resolution, and difficulty achieving spatial resolution on the order of hundreds of micrometers with large-bore scanners. These issues are mitigated through optimized imaging sequences, doped aqueous solutions, and tailored radiofrequency coils, enabling MRI to deliver detailed insights into liquid behavior and packing efficiency.

All experiments were conducted with a 3 Tesla vertical large-bore MRI system with the ability to measure samples with a height of several meters. The trickle bed included a one meter structured packing bed with a diameter of 54 mm. 3D-printed corrugated sheet packings (480 m²/m³) were studied under varying gas and liquid loadings. To shorten T₁ relaxation time to 50 ms and match the magnetic susceptibility of the gas phase, which is air, the aqueous solution was doped with 16.27 mM dysprosium(III) nitrate and 1 mM gadolinium(III) chloride. The liquid distribution was measured using a gradient echo imaging sequence. Two coil designs were compared, the system-integrated Transmit - Receive bird cage body coil and a tailored single-channel surface coil.

The coils were compared with regard to signal-to-noise ratio (SNR) and spatiotemporal resolution. Unlike the body coil, which suffers from low spatial resolution and long acquisition times, the single-channel coil enables significantly higher spatiotemporal resolution (Fig. 1). The shortened T1 relaxation times allow faster signal recovery, enabling higher temporal resolution. Using a single-channel coil, doped aqueous solution, and gradient echo sequence enables MRI with spatial resolution up to 0.25 × 0.25 × 0.3 mm³. Combining data from partially and fully filled packings (Fig. 1) enables differentiation of liquid, gas, and structured packing, allowing the determination of the gas-liquid interfacial area, which is critical for the separation efficiency. MRI-derived maldistribution factors were validated against collector experiments at the column bottom, demonstrating good agreement.

This study shows the use of MRI for temporally and spatially resolved measurements of liquid distribution in structured packings within trickle beds. A tailored surface coil, doped aqueous solutions, and optimized imaging enabled high-resolution imaging. MRI allows to distinguish between gas, liquid, and packing phases, enabling the determination of the gas–liquid interfacial area. The comparison with collector experiments showed good agreement, with MRI offering enhanced insight along the column height and improved radial resolution.
Subjects
Magnetic resonance imaging
Structured packing
Trickle bed
Radiofrequency coil
Liquid distribution
DDC Class
620: Engineering
Funding(s)
Entwurf von strukturierten Packungen mittels CFD-basierter Optimierung, Absorptionsexperimenten und Magnetresonanztomographie  
TUHH
Weiterführende Links
  • Contact
  • Send Feedback
  • Cookie settings
  • Privacy policy
  • Impress
DSpace Software

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science
Design by effective webwork GmbH

  • Deutsche NationalbibliothekDeutsche Nationalbibliothek
  • ORCiD Member OrganizationORCiD Member Organization
  • DataCiteDataCite
  • Re3DataRe3Data
  • OpenDOAROpenDOAR
  • OpenAireOpenAire
  • BASE Bielefeld Academic Search EngineBASE Bielefeld Academic Search Engine
Feedback