TUHH Open Research
Help
  • Log In
    New user? Click here to register.Have you forgotten your password?
  • English
  • Deutsch
  • Communities & Collections
  • Publications
  • Research Data
  • People
  • Institutions
  • Projects
  • Statistics
  1. Home
  2. TUHH
  3. Publication References
  4. Automatic joint alignment measurements in pre- and post-operative long leg standing radiographs
 
Options

Automatic joint alignment measurements in pre- and post-operative long leg standing radiographs

Publikationstyp
Journal Article
Date Issued
2012-12-17
Sprache
English
Author(s)
Gooßen, André  
Weber, Georg Martin  
Dries, Sebastian Peter Michael  
Institut
Bildverarbeitungssysteme E-2  
TORE-URI
http://hdl.handle.net/11420/9963
Journal
Methods of information in medicine  
Volume
51
Issue
5
Start Page
406
End Page
414
Citation
Methods of Information in Medicine 51 (5): 406-414 (2012-12-17)
Publisher DOI
10.3414/ME11-02-0033
Scopus ID
2-s2.0-84870870935
PubMed ID
23038612
Publisher
Thieme
Objectives: For diagnosis or treatment assessment of knee joint osteoarthritis it is required to measure bone morphometry from radiographic images. We propose a method for automatic measurement of joint alignment from pre-operative as well as post-operative radiographs. Methods: In a two step approach we first detect and segment any implants or other artificial objects within the image. We exploit physical characteristics and avoid prior shape information to cope with the vast amount of implant types. Subsequently, we exploit the implant delineations to adapt the initialization and adaptation phase of a dedicated bone segmentation scheme using deformable template models. Implant and bone contours are fused to derive the final joint segmentation and thus the alignment measurements. Results: We evaluated our method on clinical long leg radiographs and compared both the initialization rate, corresponding to the number of images successfully processed by the proposed algorithm, and the accuracy of the alignment measurement. Ground truth has been generated by an experienced orthopedic surgeon. For comparison a second reader reevaluated the measurements. Experiments on two sets of 70 and 120 digital radiographs show that 92% of the joints could be processed automatically and the derived measurements of the automatic method are comparable to a human reader for preoperative as well as post-operative images with a typical error of 0.7° and correlations of r = 0.82 to r = 0.99 with the ground truth. Conclusions: The proposed method allows deriving objective measures of joint alignment from clinical radiographs. Its accuracy and precision are on par with a human reader for all evaluated measurements. © Schattauer 2012.
Subjects
Bone
Lower extremity
Orthopedics
Radiography
Replacement arthroplasty
DDC Class
004: Informatik
600: Technik
610: Medizin
TUHH
Weiterführende Links
  • Contact
  • Send Feedback
  • Cookie settings
  • Privacy policy
  • Impress
DSpace Software

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science
Design by effective webwork GmbH

  • Deutsche NationalbibliothekDeutsche Nationalbibliothek
  • ORCiD Member OrganizationORCiD Member Organization
  • DataCiteDataCite
  • Re3DataRe3Data
  • OpenDOAROpenDOAR
  • OpenAireOpenAire
  • BASE Bielefeld Academic Search EngineBASE Bielefeld Academic Search Engine
Feedback