TUHH Open Research
Help
  • Log In
    New user? Click here to register.Have you forgotten your password?
  • English
  • Deutsch
  • Communities & Collections
  • Publications
  • Research Data
  • People
  • Institutions
  • Projects
  • Statistics
  1. Home
  2. TUHH
  3. Publications
  4. Design of a flexible mechatronic system for mechanical impedance measurement of the wrist as one step towards robotic rehabilitation
 
Options

Design of a flexible mechatronic system for mechanical impedance measurement of the wrist as one step towards robotic rehabilitation

Citation Link: https://doi.org/10.15480/882.8758
Publikationstyp
Journal Article
Date Issued
2023-09-01
Sprache
English
Author(s)
Tortorici, Ornella  orcid-logo
Mechatronik im Maschinenbau M-4  
Abbasimoshaei, Alireza  orcid-logo
Mechatronik im Maschinenbau M-4  
Kern, Thorsten Alexander  orcid-logo
Mechatronik im Maschinenbau M-4  
Schilling, Arndt F.  
Biomechanik M-3  
TORE-DOI
10.15480/882.8758
TORE-URI
https://hdl.handle.net/11420/43804
Journal
Current directions in biomedical engineering  
Volume
9
Issue
1
Start Page
654
End Page
657
Citation
Current Directions in Biomedical Engineering 9 (1): 654-657 (2023-09-01)
Publisher DOI
10.1515/cdbme-2023-1164
Scopus ID
2-s2.0-85173258273
Publisher
Walter de Gruyter GmbH
Home rehabilitation is a great complement to inpatient rehabilitation, because it allows for more regular training, especially in rural areas, where the access to physiotherapists is limited. However, unsupervised training carries the risk of deviation from the prescribed protocol. An obvious solution is to introduce a technical means for rehabilitation and continuous monitoring of performance. This paper presents a robotic system for rehabilitation of three degrees of freedom of the wrist independently, implemented with only one actuator, optimizing the design and size of the system. The device provides measurements of joint torque-position dependence, allowing objective assessment of mechanical impedance and range of motion to evaluate the progress of rehabilitation. Derived from research on haptic devices, a measurement method was implemented to measure hand impedance in the high frequency range between 100 and 200 Hz using a combination of exciters and accelerometers in the handles. This allows continuous monitoring of gripping forces without the need for complex contact-based force sensors. In collaboration between the authors' technical and medical universities, a set of two-level passive and active safety measures was implemented to ensure the safety of the system's users. Therefore, the presented system shows the potential to evaluate the mechanical impedance of the wrist at both low and high frequencies and to monitor the progress during rehabilitation. In the next step, a baseline of wrist impedance will be measured in a target group of healthy volunteers in order to prepare for studies in motion-restricted subjects.
Subjects
mechanical impedance measurement
robotic system
wrist rehabilitation
DDC Class
610: Medicine, Health
Publication version
publishedVersion
Lizenz
https://creativecommons.org/licenses/by/4.0/
Loading...
Thumbnail Image
Name

10.1515_cdbme-2023-1164.pdf

Type

Main Article

Size

2.24 MB

Format

Adobe PDF

TUHH
Weiterführende Links
  • Contact
  • Send Feedback
  • Cookie settings
  • Privacy policy
  • Impress
DSpace Software

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science
Design by effective webwork GmbH

  • Deutsche NationalbibliothekDeutsche Nationalbibliothek
  • ORCiD Member OrganizationORCiD Member Organization
  • DataCiteDataCite
  • Re3DataRe3Data
  • OpenDOAROpenDOAR
  • OpenAireOpenAire
  • BASE Bielefeld Academic Search EngineBASE Bielefeld Academic Search Engine
Feedback