  4. Biomechanical principles of a permanently durable abdominal wall reconstruction: current status and potential future development
 
Options

Biomechanical principles of a permanently durable abdominal wall reconstruction: current status and potential future development

Citation Link: https://doi.org/10.15480/882.8187
Publikationstyp
Review Article
Date Issued
2023-07-25
Sprache
English
Author(s)
Nessel, Regine  
Lesch, Carolin  
Vollmer, Matthias  
Biomechanik M-3  
Kallinowski, Friedrich  
TORE-DOI
10.15480/882.8187
TORE-URI
https://hdl.handle.net/11420/42697
Journal
Mini-invasive surgery  
Volume
7
Start Page
1
End Page
8
Article Number
21
Citation
Mini-invasive Surgery 7: 21 (2023)
Publisher DOI
10.20517/2574-1225.2023.21
Scopus ID
2-s2.0-85165638141
Publisher
OAE Publishing, Inc
The article reviews the biomechanical principles of durable abdominal wall reconstructions. The aim is to provide insights and conclusions for future research in this area. Incisional hernia repair implies the creation of a compound made of tissue, textile, and fixation elements. A pulse load bench test for incisional hernia repair has been available since 2014, and its influences are evaluated in three different versions of the test stand. Based on these evaluations, a biomechanical concept for long-term durable reconstructions was determined. To apply the concept to individual patients, computed tomography of the abdomen at rest and during the Valsalva maneuver was used. A load limit can be given for every patient based on the hernia defect area (CRIP- critical resistance to impacts related to pressure). By considering the mesh to defect area ratio, the retention strength of a planned reconstruction can be calculated (GRIP-gained resistance to impacts related to pressure). The gripping coefficients for tissues vary significantly, up to 18 fold. About half of the patients have overall tissue distensions up to 350% or more, with potential high regional variations. The surface retention forces for hernia meshes and for different sutures, tacks, and adhesives span a wide range of 14fold. Suturing a defect strengthens the reconstruction up to 3fold. Furthermore, recalculating data taken from multicentric randomized studies on primary sutures reveals that improved GRIP values are associated with reduced rates of incisional hernia. Repairing consecutive incisional hernias according to the GRIP concept results in no recurrence and low pain levels after one year. A future policy for market access of repair materials should include cyclic load bench testing. Moreover, a tailored approach to incisional hernia repair should take into account the biomechanical aspects involved.
Subjects
biomechanically calculateed hernia repair
biomechanics
durable hernia repair
durable incisional hernia repair
GRIP
Hernia
incisional hernia
DDC Class
600: Technology
Publication version
publishedVersion
Lizenz
https://creativecommons.org/licenses/by/4.0/
No Thumbnail Available
Name

5861.pdf

Type

Main Article

Size

503.36 KB

Format

Adobe PDF

TUHH
Weiterführende Links
  • Contact
  • Send Feedback
  • Cookie settings
  • Privacy policy
  • Impress
DSpace Software

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science
Design by effective webwork GmbH

  • Deutsche NationalbibliothekDeutsche Nationalbibliothek
  • ORCiD Member OrganizationORCiD Member Organization
  • DataCiteDataCite
  • Re3DataRe3Data
  • OpenDOAROpenDOAR
  • OpenAireOpenAire
  • BASE Bielefeld Academic Search EngineBASE Bielefeld Academic Search Engine
Feedback