Options
Druckverlustuntersuchung von Fahrzeugkältemittelleitungen
Publikationstyp
Journal Article
Publikationsdatum
2021-02
Sprache
German
Institut
TORE-URI
Enthalten in
Volume
57
Issue
01-02
Start Page
41
End Page
47
Citation
Ki Kälte Luft Klimatechnik 57 (1-2): 41-47 (2021-02)
Publisher Link
Publisher
Hüthig Verlag
Vehicle refrigerant pipe pressure drop can have a major impact on efficiency. In order to determine this experimentally, a test facility was set up. CFD simulations are carried out in parallel. It turns out that shoulders inside the hose junctions produce greater losses. After taking them into account, good results are possible using CFD.
Schlagworte
Druckverlust
Kältemittelleitung
Fahrzeug
Versuchsanlage
R1234yf