The influence of in vitro testing method on measured intervertebral disc characteristics

Publikationstyp
Conference Paper
Date Issued
2002
Sprache
English
Author(s)
Huber, Gerd  
Biomechanik M-3  
Linke, Berend
Morlock, Michael  
Biomechanik M-3  
Ito, Keita
TORE-URI
https://hdl.handle.net/11420/46680
Issue
1431
Start Page
101
End Page
113
Citation
Spinal implants : are we evaluating them appropriately? - West Conshohocken, Pa., 2003. - (ASTM STP ; vol 1431). - Seite 103-113
Scopus ID
2-s2.0-0038543217
Publisher
ASTM International
ISBN
978-0-8031-3463-8
Time-dependent behavior of functional spinal units, especially the anterior column, may interact with experimental methods when measuring their mechanical properties. Since they are tested using different load cycles, the comparison of results is difficult. The goal of this study was to determine the response of anterior column spinal units (body-disc-body units) to load cycles varying in waveform and cycle duration using an experimentally based mathematical model. Specimen specific transfer function models were formulated for seven ovine lumbar anterior column units by fitting high order exponential functions to axial stress-relaxation measurements. Using axial load cycles with different waveforms and cycle durations, nine simulations in the time domain with each transfer function model were performed. For each simulation, the neutral zone, peak to peak, and hysteresis were evaluated. The neutral zone and hysteresis were significantly dependent on the waveform of the load cycle. The differences of peak to peak for sinusoidal and triangular waveforms were low. All these characteristics were significantly dependent on the cycle duration. For example, comparison of 1 s to 20 s cycle durations exhibited neutral zone and hysteresis differences of 61-69% and 100%, respectively. Consequently, loading protocols should be chosen carefully and should be clearly reported.
Subjects
Dynamic model
Hysteresis area
Intervertebral disc
In vitro testing
Neutral zone
Peak to peak
Stress relaxation
DDC Class
610: Medicine, Health
TUHH
Weiterführende Links
  • Contact
  • Send Feedback
  • Cookie settings
  • Privacy policy
  • Impress
DSpace Software

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science
Design by effective webwork GmbH

  • Deutsche NationalbibliothekDeutsche Nationalbibliothek
  • ORCiD Member OrganizationORCiD Member Organization
  • DataCiteDataCite
  • Re3DataRe3Data
  • OpenDOAROpenDOAR
  • OpenAireOpenAire
  • BASE Bielefeld Academic Search EngineBASE Bielefeld Academic Search Engine
Feedback