Publisher DOI: 10.1021/acs.jpcc.1c06798
arXiv ID: 2111.12192v1
Title: Statistical Analysis of Submicron X-Ray Tomography Data on Polymer Imbibition into Arrays of Cylindrical Nanopores
Language: English
Authors: Vazquez, Luna F. 
Gerstenberger, Michael 
Dittrich, Guido 
Silva, Juliana Martins Souza 
Huber, Patrick  
Wehrspohn, Ralf 
Steinhart, Martin 
Keywords: Physics - Chemical Physics; Physics - Chemical Physics
Issue Date: 9-Dec-2021
Source: Journal of Physical Chemistry C 125 (48) : 26731-26743 (2021-12-09)
Abstract (english): 
Frozen transient imbibition states in arrays of straight cylindrical pores 400 nm in diameter were imaged by phase-contrast X-ray computed tomography with single-pore resolution. A semi-automatic algorithm yielding brightness profiles along all pores identified within the probed sample volume is described. Imbibition front positions are determined by descriptive statistics. A first approach involves the evaluation of frequency densities of single-pore imbibition lengths, a second one the evaluation of the statistical brightness dispersion within the probed volume as a function of the distance from the pore mouths. We plotted average imbibition front positions against systematically varied powers of the imbibition time and determined the optimal exponent of the imbibition time by considering the correlation coefficients of the corresponding linear fits. Thus, slight deviations from the proportionality of the average imbibition front position to the square root of the imbibition time predicted by the Lucas-Washburn theory were found. A meaningful preexponential factor in the power law relating imbibition front position and imbibition time may only be determined after ambiguities regarding the exponent of the imbibition time are resolved. The dispersion of peaks representing the imbibition front in frequency densities of single-pore imbibition lengths and in brightness dispersion profiles plotted against the pore depth is suggested as measure of the imbibition front width. Phase-contrast X-ray computed tomography allows the evaluation of a large number of infiltrated submicron pores taking advantage of phase-contrast imaging; artifacts related to sample damage by tomography requiring physical ablation of sample material are avoided.
URI: http://hdl.handle.net/11420/11265
ISSN: 1932-7447
Journal: The journal of physical chemistry C 
Institute: Material- und Röntgenphysik M-2 
Document Type: Article
Project: Oxidische 3d-Gerüststrukturen für benetzungsvermittelte Formgebung von Polymeren und benetzungsvermitteltes Herstellen von Fügeverbindungen mit Polymeren 
Appears in Collections:Publications without fulltext

Show full item record

Page view(s)

41
Last Week
1
Last month
checked on Nov 28, 2022

Google ScholarTM

Check

Add Files to Item

Note about this record

Cite this record

Export

Items in TORE are protected by copyright, with all rights reserved, unless otherwise indicated.