  4. Combining peridynamic and finite element simulations to capture the corrosion of degradable bone implants and to predict their residual strength
 
Options

Combining peridynamic and finite element simulations to capture the corrosion of degradable bone implants and to predict their residual strength

Publikationstyp
Journal Article
Date Issued
2022-04-15
Sprache
English
Author(s)
Hermann, Alexander  
Shojaei, Arman  
Steglich, Dirk  
Höche, Daniel  
Zeller-Plumhoff, Berit  
Cyron, Christian J.  
Institut
Kontinuums- und Werkstoffmechanik M-15  
TORE-URI
http://hdl.handle.net/11420/11983
Journal
International journal of mechanical sciences  
Volume
220
Article Number
107143
Citation
International Journal of Mechanical Sciences 220: 107143 (2022-04-15)
Publisher DOI
10.1016/j.ijmecsci.2022.107143
Scopus ID
2-s2.0-85125544567
This paper proposes a computational framework to describe the biodegradation of magnesium (Mg)-based bone implants. It is based on a sequential combination of two models: an electrochemical corrosion model to compute the mass loss of the implant over several weeks combined with a mechanical model to assess its residual mechanical strength. The first model uses a peridynamic (PD) corrosion model to tackle the complex moving boundary of the corroding material in an efficient manner. The results of this corrosion simulation are mapped to a finite element (FE) model by way of a damage variable. Subsequently, the FE model is used for mechanical analysis. To use PD for such a complex problem, we proposed three innovative improvements compared to state-of-the-art PD models: (1) application of an adaptive multi-grid discretization in space and an implicit time-stepping algorithm enabling an efficient simulation of the complex implant geometry over prolonged periods, (2) novel non-local Dirichlet absorbing boundary conditions to truncate the simulation domain in the close neighborhood of the implant of interest without prohibitive losses of accuracy, and (3) selection of suitable non-local kernel functions and parameter calibration on the basis of experimental data by an evolutionary algorithm. We demonstrate that this framework can capture the loss of implant mass due to corrosion for typical alloys such as Mg-5Gd and Mg-10Gd. Moreover, we point out how this framework can be used in the future to predict the declining mechanical strength of bone screws subject to biocorrosion over several weeks.
Subjects
Mass loss
Mg-Gd alloys
Moving interface
Multi-grid
Non-local diffusion
Strength reduction
TUHH
Weiterführende Links
  • Contact
  • Send Feedback
  • Cookie settings
  • Privacy policy
  • Impress
DSpace Software

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science
Design by effective webwork GmbH

  • Deutsche NationalbibliothekDeutsche Nationalbibliothek
  • ORCiD Member OrganizationORCiD Member Organization
  • DataCiteDataCite
  • Re3DataRe3Data
  • OpenDOAROpenDOAR
  • OpenAireOpenAire
  • BASE Bielefeld Academic Search EngineBASE Bielefeld Academic Search Engine
Feedback