dc.description.abstractPatients using implantable devices with wireless power transmission (such as inductive telemetry) as the energy source are required to carry external hardware and antennas on their body continuously during the monitoring period. This discomfort can be reduced by integrating tiny super-capacitors as an energy source for the device. The external wireless telemetry unit used to activate and interrogate the implantable device charges the super capacitors integrated on it. When the wireless telemetry unit is removed, the super capacitor powers the implantable device. This paper shows the benefits of integrating super capacitors onto an existing pressure sensing medical implant that utilises an inductive telemetry link. Test results show that the implant can be powered for a full day using an 88 mF super capacitor. This super capacitor can be fully charged using the inductive telemetry link at a wireless distance of 20 cm in 81 seconds.en
dc.language.isoende_DE
dc.titleSuper-capacitors for implantable medical devices with wireless power transmissionde_DE
dc.typeinProceedingsde_DE
dc.type.dinicontributionToPeriodical-
dcterms.DCMITypeText-
tuhh.abstract.englishPatients using implantable devices with wireless power transmission (such as inductive telemetry) as the energy source are required to carry external hardware and antennas on their body continuously during the monitoring period. This discomfort can be reduced by integrating tiny super-capacitors as an energy source for the device. The external wireless telemetry unit used to activate and interrogate the implantable device charges the super capacitors integrated on it. When the wireless telemetry unit is removed, the super capacitor powers the implantable device. This paper shows the benefits of integrating super capacitors onto an existing pressure sensing medical implant that utilises an inductive telemetry link. Test results show that the implant can be powered for a full day using an 88 mF super capacitor. This super capacitor can be fully charged using the inductive telemetry link at a wireless distance of 20 cm in 81 seconds.de_DE
tuhh.publisher.doi10.1109/PRIME.2018.8430360-
tuhh.publication.instituteIntegrierte Schaltungen E-9de_DE
tuhh.type.opusInProceedings (Aufsatz / Paper einer Konferenz etc.)-
tuhh.institute.germanIntegrierte Schaltungen E-9de
tuhh.institute.englishIntegrierte Schaltungen E-9de_DE
tuhh.gvk.hasppnfalse-
dc.type.drivercontributionToPeriodical-
dc.type.casraiConference Paper-
tuhh.container.startpage241de_DE
tuhh.container.endpage244de_DE
dc.relation.conference14th Conference on Ph.D. Research in Microelectronics and Electronics (PRIME 2018)de_DE
dc.identifier.scopus2-s2.0-85052530893-
datacite.resourceTypeConference Paper-
datacite.resourceTypeGeneralText-
item.openairecristypehttp://purl.org/coar/resource_type/c_5794-
item.languageiso639-1en-
item.creatorGNDMendoza Ponce, Pablo Daniel-
item.creatorGNDJohn, Bibin-
item.creatorGNDSchröder, Dietmar-
item.creatorGNDKrautschneider, Wolfgang-
item.mappedtypeinProceedings-
item.cerifentitytypePublications-
item.openairetypeinProceedings-
item.fulltextNo Fulltext-
item.grantfulltextnone-
item.creatorOrcidMendoza Ponce, Pablo Daniel-
item.creatorOrcidJohn, Bibin-
item.creatorOrcidSchröder, Dietmar-
item.creatorOrcidKrautschneider, Wolfgang-
crisitem.author.deptIntegrierte Schaltungen E-9-
crisitem.author.deptIntegrierte Schaltungen E-9-
crisitem.author.deptIntegrierte Schaltungen E-9-
crisitem.author.deptIntegrierte Schaltungen E-9-
crisitem.author.orcid0000-0003-1048-577X-
crisitem.author.orcid0000-0001-8629-4545-
crisitem.author.parentorgStudiendekanat Elektrotechnik, Informatik und Mathematik (E)-
crisitem.author.parentorgStudiendekanat Elektrotechnik, Informatik und Mathematik (E)-
crisitem.author.parentorgStudiendekanat Elektrotechnik, Informatik und Mathematik (E)-
crisitem.author.parentorgStudiendekanat Elektrotechnik, Informatik und Mathematik (E)-
Appears in Collections:Publications without fulltext
Show simple item record

Page view(s)

453
Last Week
1
Last month
0
checked on Jun 8, 2023

SCOPUSTM   
Citations

6
Last Week
0
Last month
1
checked on Jun 30, 2022

Google ScholarTM

Check

Add Files to Item

Note about this record

Cite this record

Export

Items in TORE are protected by copyright, with all rights reserved, unless otherwise indicated.