TUHH Open Research
Help
  • Log In
    New user? Click here to register.Have you forgotten your password?
  • English
  • Deutsch
  • Communities & Collections
  • Publications
  • Research Data
  • People
  • Institutions
  • Projects
  • Statistics
  1. Home
  2. TUHH
  3. Publications
  4. Deformation of acetabular press-fit cups: influence of design and surgical factors
 
Options

Deformation of acetabular press-fit cups: influence of design and surgical factors

Citation Link: https://doi.org/10.15480/882.2363
Publikationstyp
Journal Article
Date Issued
2019-07-13
Sprache
English
Author(s)
Messer-Hannemann, Philipp  
Campbell, Graeme Michael  
Morlock, Michael  
Institut
Biomechanik M-3  
TORE-DOI
10.15480/882.2363
TORE-URI
http://hdl.handle.net/11420/3058
Journal
Clinical biomechanics  
Volume
69
Start Page
96
End Page
103
Citation
Clinical Biomechanics (69): 96-103 (2019-10)
Publisher DOI
10.1016/j.clinbiomech.2019.07.014
Scopus ID
2-s2.0-85068977169
Publisher
Elsevier Science
Background: Deformation of acetabular cups when press-fitted into an undersized cavity is inevitable due to the inhomogeneous stiffness of acetabular bone. Thinner cups or screw holes might increase the risk of high cup deformation. The aim of this study was to examine the influence of cup design and liner assembly on the deformation response during cup implantation. Methods: Acetabular cups with different designs were implanted into polyurethane foam models simulating the anatomical situation with nominal press-fits of 1mm and without nominal press-fits (line-to-line). Deformations were determined using a tactile coordinate measuring machine. A 3D laser scanner was used to determine the contact conditions at the cup-cavity interface. Polyethylene and ceramic liners were assembled to the implanted cups and the influence of the insertion on the deformation response evaluated. Fixation strength of the cups was determined by push-out testing. Findings: Cup deformation increased with smaller wall thickness (P < 0.037) and screw holes (P < 0.001). Insertion of ceramic liners reduced the deformation (P < 0.001), whereas polyethylene liners adapted to the deformation of the implanted cups (P > 0.999). Thin-walled cups exhibited a higher fixation strength for similar implantation forces (P = 0.011). Interpretation: Thin-walled cups achieved higher fixation strengths and might be more bone-preserving. However, in combination with screw holes and high press-fit levels, wall thickness should be considered carefully to avoid excessive cup deformations leading to potential complications during liner assembly. Line-to-line insertion of thin-walled cups should be accompanied with a rough surface coating to minimize the loss of fixation strength due to the low press-fit fixation.
Subjects
hip arthroplasty
press-fit
cup deformation
primary stability
contact condition
DDC Class
570: Biowissenschaften, Biologie
610: Medizin
Lizenz
https://creativecommons.org/licenses/by-nc-nd/4.0/
Loading...
Thumbnail Image
Name

Messer-Hannemann P 2019 ClinBio Deformation of acetabular press-fit cups - Influence of design and surgical factors.pdf

Size

1.62 MB

Format

Adobe PDF

TUHH
Weiterführende Links
  • Contact
  • Send Feedback
  • Cookie settings
  • Privacy policy
  • Impress
DSpace Software

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science
Design by effective webwork GmbH

  • Deutsche NationalbibliothekDeutsche Nationalbibliothek
  • ORCiD Member OrganizationORCiD Member Organization
  • DataCiteDataCite
  • Re3DataRe3Data
  • OpenDOAROpenDOAR
  • OpenAireOpenAire
  • BASE Bielefeld Academic Search EngineBASE Bielefeld Academic Search Engine
Feedback