Publisher DOI: 10.1093/ejcts/ezy188
Title: Transcatheter mitral valve implantation: supra-annular and subvalvular fixation techniques
Language: English
Authors: Loger, Klaas 
Lutter, Georg 
Huenges, Katharina 
Frank, Derk 
Groß, Justus 
Cremer, Jochen 
Attmann, Tim 
Morlock, Michael 
Pokorny, Saskia 
Keywords: Transcatheter;Mitral valve;Stent;Fixation;Percutaneous;Transapical
Issue Date: 19-Jul-2018
Publisher: Oxford Univ. Press
Source: European Journal of Cardio-thoracic Surgery 6 (54): 1013-1021 (2018)
Journal or Series Name: European journal of cardio-thoracic surgery 
Abstract (english): OBJECTIVES: Transcatheter mitral valved stent implantation provides an off-pump treatment option for mitral valve regurgitation, especially for secondary mitral valve regurgitation. The aim of this study was to evaluate novel fixation strategies: direct fixation (SUPRA) and subvalvular fixation (sub-VALV) to successfully implement alternative fixation methods at the mitral annulus and to reduce radial stent and apical tether forces. METHODS: Specific concepts were developed for the supra-annular hook-shaped fixation (SUPRA) and the subvalvular fixation (sub-VALV). These prototypes were compared with the sole apical tether fixation (AP) methods. Thirty-three pigs underwent mitral valved stent implantation accompanied by standardized transoesophageal echocardiographic and haemodynamic evaluation of heart function and the stent performance 1 h after implantation. Additionally, animals were followed up for 3 months. RESULTS: Secure deployment and correct positioning with low transvalvular gradients were achieved in all cases with mitral valved stent implantation. Nevertheless, 2 pigs died due to rhythm disturbances during dissection and pre-transcatheter mitral valve implantation. Paravalvular leakages were trace or less in prototypes with supra-annular fixation and sole apical fixation. In contrast, moderate paravalvular leakages were observed in the sub-VALV group (P < 0.001). In addition, the effect of a specific stent design on heart function was demonstrated: an increased rate of ischaemia and arrhythmia (P = 0.037) and a small left ventricular ejection fraction reduction (P < 0.05) were observed in the group with subvalvular fixation. In all but 1 case, gross evaluation demonstrated a good ingrowth of the valved stents of between 36% and 100% tissue coverage after a follow-up of 1 month or longer. CONCLUSIONS: The low degree of paravalvular leakages in the supra-annular and apical fixation groups and the normal longitudinal function highlight the good alignment of these new mitral valved stent designs within the native anatomy. The novel, hook-shaped, supra-annular fixation elements were well tolerated in the hearts resulting in excellent health of the animals at long-term follow-up times of up to 3 months.
URI: http://hdl.handle.net/11420/3099
ISSN: 1010-7940
Institute: Biomechanik M-3 
Type: (wissenschaftlicher) Artikel
Appears in Collections:Publications without fulltext

Show full item record

Page view(s)

52
Last Week
0
Last month
4
checked on Sep 23, 2020

Google ScholarTM

Check

Add Files to Item

Note about this record

Export

Items in TORE are protected by copyright, with all rights reserved, unless otherwise indicated.