TUHH Open Research
Help
  • Log In
    New user? Click here to register.Have you forgotten your password?
  • English
  • Deutsch
  • Communities & Collections
  • Publications
  • Research Data
  • People
  • Institutions
  • Projects
  • Statistics
  1. Home
  2. TUHH
  3. Publication References
  4. Micromotion at the head-stem taper junction of total hip prostheses is influenced by prosthesis design-, patient- and surgeon-related factors
 
Options

Micromotion at the head-stem taper junction of total hip prostheses is influenced by prosthesis design-, patient- and surgeon-related factors

Publikationstyp
Journal Article
Date Issued
2020-01-02
Sprache
English
Author(s)
Falkenberg, Adrian  
Biller, Sara  
Morlock, Michael  
Huber, Gerd  
Institut
Biomechanik M-3  
TORE-URI
http://hdl.handle.net/11420/4244
Journal
Journal of biomechanics  
Volume
98
Article Number
109424
Citation
Journal of Biomechanics (98): 109424 (2020-01-02)
Publisher DOI
10.1016/j.jbiomech.2019.109424
Scopus ID
2-s2.0-85074423073
Taper junctions of modular hip prostheses are susceptible to fretting and crevice corrosion. Prevalence and significance increase for cobalt-chromium heads assembled on titanium-alloy stems. Retrieval and in-vitro studies have identified micromotion between the taper components to accelerate the corrosion process. The aim of this study was to identify the most critical factors contributing to increased micromotion, which is most likely influenced by design-, patient- and surgeon-related aspects. Micromotion between head and stem taper surfaces was measured for different taper surface topographies and load orientations. Consecutive visual images were recorded through windows in the head component. By image matching analysis the local micromotions at the taper junction between head and stem tapers were determined. To extend the findings to taper regions not visible through the windows, finite element models were generated. The models were further utilized to investigate the influence of head length, taper angle difference and assembly force on micromotion. Significantly higher micromotion (+20%) was found under varus loading (7.1 µm) in comparison to valgus loading (5.9 µm). Smooth and microgrooved stem tapers exhibited equal amounts of micromotion. The numerical model revealed head tilting and recurring taper contact changes in terms of cyclic engagement/disengagement during the loading sequences. Especially long heads (+240%) and low assembly forces (+53%) were found to substantially increase micromotion (from 2.7 µm to 9.3 µm and from 4.1 µm to 8.8 µm, respectively). This study accentuates the susceptibility of taper junctions to a variety of factors, which need to be appreciated in preoperative planning and surgical procedure to reduce the amount of micromotion and such minimize the risk of critical corrosion.
Subjects
Assembly force
Head length
Head-stem taper junction
Micromotion
Taper surface topography
TUHH
Weiterführende Links
  • Contact
  • Send Feedback
  • Cookie settings
  • Privacy policy
  • Impress
DSpace Software

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science
Design by effective webwork GmbH

  • Deutsche NationalbibliothekDeutsche Nationalbibliothek
  • ORCiD Member OrganizationORCiD Member Organization
  • DataCiteDataCite
  • Re3DataRe3Data
  • OpenDOAROpenDOAR
  • OpenAireOpenAire
  • BASE Bielefeld Academic Search EngineBASE Bielefeld Academic Search Engine
Feedback