TUHH Open Research
Help
  • Log In
    New user? Click here to register.Have you forgotten your password?
  • English
  • Deutsch
  • Communities & Collections
  • Publications
  • Research Data
  • People
  • Institutions
  • Projects
  • Statistics
  1. Home
  2. TUHH
  3. Publications
  4. A clinically evaluated interferometric continuous-wave radar system for the contactless measurement of human vital parameters
 
Options

A clinically evaluated interferometric continuous-wave radar system for the contactless measurement of human vital parameters

Citation Link: https://doi.org/10.15480/882.2825
Publikationstyp
Journal Article
Date Issued
2019-05-31
Sprache
English
Author(s)
Michler, Fabian  
Shi, Kilin  
Schellenberger, Sven  orcid-logo
Steigleder, Tobias  
Malessa, Anke  
Hameyer, Laura  
Neumann, Nina  
Lurz, Fabian  
Ostgathe, Christoph  
Weigel, Robert  
Kölpin, Alexander  orcid-logo
TORE-DOI
10.15480/882.2825
TORE-URI
http://hdl.handle.net/11420/6443
Journal
Sensors  
Volume
19
Issue
11
Article Number
2492
Citation
Sensors (Switzerland) 11 (19): 2492 (2019-06-01)
Publisher DOI
10.3390/s19112492
Scopus ID
2-s2.0-85067204020
Publisher
MDPI
Vital parameters are key indicators for the assessment of health. Conventional methods rely on direct contact with the patients’ skin and can hence cause discomfort and reduce autonomy. This article presents a bistatic 24 GHz radar system based on an interferometric six-port architecture and features a precision of 1 µm in distance measurements. Placed at a distance of 40 cm in front of the human chest, it detects vibrations containing respiratory movements, pulse waves and heart sounds. For the extraction of the respiration rate, time-domain approaches like autocorrelation, peaksearch and zero crossing rate are compared to the Fourier transform, while template matching and a hidden semi-Markov model are utilized for the detection of the heart rate from sphygmograms and heart sounds. A medical study with 30 healthy volunteers was conducted to collect 5.5 h of data, where impedance cardiogram and electrocardiogram were used as gold standard for synchronously recording respiration and heart rate, respectively. A low root mean square error for the breathing rate (0.828 BrPM) and a high overall F1 score for heartbeat detection (93.14%) could be achieved using the proposed radar system and signal processing.
Subjects
Continuous wave radar
Remote sensing
Six-port interferometry
Vital parameter measurement
DDC Class
600: Technik
610: Medizin
More Funding Information
Funding: The research project GUARDIAN was funded by the Federal Ministry of Education and Research, Berlin, Germany, grant number 16SV7694.
Acknowledgments: We acknowledge support by Deutsche Forschungsgemeinschaft and Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU) within the funding programme Open Access Publishing.
Lizenz
https://creativecommons.org/licenses/by/4.0/
Loading...
Thumbnail Image
Name

sensors-19-02492-v2.pdf

Size

2.13 MB

Format

Adobe PDF

TUHH
Weiterführende Links
  • Contact
  • Send Feedback
  • Cookie settings
  • Privacy policy
  • Impress
DSpace Software

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science
Design by effective webwork GmbH

  • Deutsche NationalbibliothekDeutsche Nationalbibliothek
  • ORCiD Member OrganizationORCiD Member Organization
  • DataCiteDataCite
  • Re3DataRe3Data
  • OpenDOAROpenDOAR
  • OpenAireOpenAire
  • BASE Bielefeld Academic Search EngineBASE Bielefeld Academic Search Engine
Feedback