TUHH Open Research
Help
  • Log In
    New user? Click here to register.Have you forgotten your password?
  • English
  • Deutsch
  • Communities & Collections
  • Publications
  • Research Data
  • People
  • Institutions
  • Projects
  • Statistics
  1. Home
  2. TUHH
  3. Publication References
  4. Biomechanical comparison of titanium miniplates versus a variety of CAD/CAM plates in mandibular reconstruction
 
Options

Biomechanical comparison of titanium miniplates versus a variety of CAD/CAM plates in mandibular reconstruction

Publikationstyp
Journal Article
Date Issued
2020-11
Sprache
English
Author(s)
Steffen, Claudius  
Sellenschloh, Kay  
Vollmer, Matthias  
Morlock, Michael  
Heiland, Max  
Huber, Gerd  
Rendenbach, Carsten  
Institut
Biomechanik M-3  
TORE-URI
http://hdl.handle.net/11420/7182
Journal
Journal of the mechanical behavior of biomedical materials  
Volume
111
Article Number
104007
Citation
Journal of the Mechanical Behavior of Biomedical Materials (111): 104007 (2020-11)
Publisher DOI
10.1016/j.jmbbm.2020.104007
Scopus ID
2-s2.0-85089653337
Background: Titanium plate fixation of free flaps in mandibular reconstruction involves complications such as osseous non-union or imaging artefacts. Interosteotomy movement (IOM) is known to affect bone healing. This study aimed to compare IOM and mechanical integrity of four different fixation systems in a mandible reconstruction model. Methods: Two polyurethane (PU) fibula segments were fixed in right-sided defects of PU mandibles. Laser-melted patient-specific titanium plates were fixed with non-locking-screws (Ti-NL) or locking-screws (Ti-L). The third group consisted of locking-screws for patient-specific polyetheretherketone (PEEK-L) plates. The last group used titanium miniplates and monocortical screw fixation (Ti-MP). All models were loaded unilaterally via cyclic dynamic loading with increasing loads to simulate mastication. IOM was registered using a 3D optical tracking system. Findings: PEEK-L showed highest vertical displacement (p = 0.010), lowest stiffness (p = 0.004) and highest IOM (p = 0.001). All specimen in PEEK-L demonstrated abnormal bending (n = 5) or plate fracture (n = 1). Vertical displacement or stiffness did not differ between any of Ti-MP, Ti-L and Ti-NL. IOM in Ti-MP was higher than in Ti-L and Ti-NL (p = 0.001). Interpretation: Mechanical integrity of all titanium plates complies with established standards. In this model, the screw system did not influence IOM. In the tested composition and shape, PEEK plates do not seem to guarantee sufficient mechanical integrity for a use in mandibular reconstruction. Thus modifications are needed. Future clinical studies are needed to clarify optimal IOM after mandible reconstruction.
Subjects
Biomechanics
CAD/CAM
Fibula free flap
Mandible reconstruction
Mechanical integrity
PEEK
TUHH
Weiterführende Links
  • Contact
  • Send Feedback
  • Cookie settings
  • Privacy policy
  • Impress
DSpace Software

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science
Design by effective webwork GmbH

  • Deutsche NationalbibliothekDeutsche Nationalbibliothek
  • ORCiD Member OrganizationORCiD Member Organization
  • DataCiteDataCite
  • Re3DataRe3Data
  • OpenDOAROpenDOAR
  • OpenAireOpenAire
  • BASE Bielefeld Academic Search EngineBASE Bielefeld Academic Search Engine
Feedback