Please use this identifier to cite or link to this item:
https://doi.org/10.15480/882.3250
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Silva Teixeira, Viviane | - |
dc.contributor.author | Labitzky, Vera | - |
dc.contributor.author | Schumacher, Udo | - |
dc.contributor.author | Krautschneider, Wolfgang | - |
dc.date.accessioned | 2021-02-12T12:28:40Z | - |
dc.date.available | 2021-02-12T12:28:40Z | - |
dc.date.issued | 2020-11-26 | - |
dc.identifier.citation | Current Directions in Biomedical Engineering 3 (6): 20203088 (2020) | de_DE |
dc.identifier.issn | 2364-5504 | de_DE |
dc.identifier.uri | http://hdl.handle.net/11420/8448 | - |
dc.description.abstract | Cancer and normal tissues are visually different from each other, especially so in more advanced cancer stages. More important, they are not only visually contrasting, but if an electric field is applied to both tissue types and the frequency is varied in a wide range, it will be seen that the two tissue types in general have a spectral response divergent from each other and this has to do with the characteristics of cancer tissues in contrast to normal ones. In this work, Electrical Impedance Spectroscopy is applied to try to distinguish cancer from healthy tissues by means of their impedance spectrum using a four-electrode-terminal setup. The use of the fourterminal- setup setup is important to circumvent the impact of electrode polarization at frequencies below 1 kHz. | en |
dc.language.iso | en | de_DE |
dc.publisher | De Gruyter | de_DE |
dc.relation.ispartof | Current directions in biomedical engineering | de_DE |
dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | de_DE |
dc.subject | Cancer cells | de_DE |
dc.subject | electrical impedance spectroscopy | de_DE |
dc.subject | four electrode terminal setup | de_DE |
dc.subject | impedance spectrum | de_DE |
dc.subject | malignant tumors | de_DE |
dc.subject | normal cells | de_DE |
dc.subject | normal tissues | de_DE |
dc.subject.ddc | 004: Informatik | de_DE |
dc.subject.ddc | 600: Technik | de_DE |
dc.title | Use of electrical impedance spectroscopy to distinguish cancer from normal tissues with a four electrode terminal setup | de_DE |
dc.type | Article | de_DE |
dc.identifier.doi | 10.15480/882.3250 | - |
dc.type.dini | article | - |
dcterms.DCMIType | Text | - |
tuhh.identifier.urn | urn:nbn:de:gbv:830-882.0120986 | - |
tuhh.oai.show | true | de_DE |
tuhh.abstract.english | Cancer and normal tissues are visually different from each other, especially so in more advanced cancer stages. More important, they are not only visually contrasting, but if an electric field is applied to both tissue types and the frequency is varied in a wide range, it will be seen that the two tissue types in general have a spectral response divergent from each other and this has to do with the characteristics of cancer tissues in contrast to normal ones. In this work, Electrical Impedance Spectroscopy is applied to try to distinguish cancer from healthy tissues by means of their impedance spectrum using a four-electrode-terminal setup. The use of the fourterminal- setup setup is important to circumvent the impact of electrode polarization at frequencies below 1 kHz. | de_DE |
tuhh.publisher.doi | 10.1515/cdbme-2020-3088 | - |
tuhh.publication.institute | Integrierte Schaltungen E-9 | de_DE |
tuhh.identifier.doi | 10.15480/882.3250 | - |
tuhh.type.opus | (wissenschaftlicher) Artikel | - |
dc.type.driver | article | - |
dc.type.casrai | Journal Article | - |
tuhh.container.issue | 3 | de_DE |
tuhh.container.volume | 6 | de_DE |
dc.rights.nationallicense | false | de_DE |
dc.identifier.scopus | 2-s2.0-85097317930 | de_DE |
tuhh.container.articlenumber | 20203088 | de_DE |
local.status.inpress | false | de_DE |
local.type.version | publishedVersion | de_DE |
datacite.resourceType | Journal Article | - |
datacite.resourceTypeGeneral | Text | - |
item.grantfulltext | open | - |
item.creatorGND | Silva Teixeira, Viviane | - |
item.creatorGND | Labitzky, Vera | - |
item.creatorGND | Schumacher, Udo | - |
item.creatorGND | Krautschneider, Wolfgang | - |
item.languageiso639-1 | en | - |
item.fulltext | With Fulltext | - |
item.openairetype | Article | - |
item.mappedtype | Article | - |
item.creatorOrcid | Silva Teixeira, Viviane | - |
item.creatorOrcid | Labitzky, Vera | - |
item.creatorOrcid | Schumacher, Udo | - |
item.creatorOrcid | Krautschneider, Wolfgang | - |
item.cerifentitytype | Publications | - |
item.openairecristype | http://purl.org/coar/resource_type/c_6501 | - |
crisitem.author.dept | Integrierte Schaltungen E-9 | - |
crisitem.author.dept | Integrierte Schaltungen E-9 | - |
crisitem.author.orcid | 0000-0001-8629-4545 | - |
crisitem.author.parentorg | Studiendekanat Elektrotechnik, Informatik und Mathematik (E) | - |
crisitem.author.parentorg | Studiendekanat Elektrotechnik, Informatik und Mathematik (E) | - |
Appears in Collections: | Publications with fulltext |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
[23645504 - Current Directions in Biomedical Engineering] Use of Electrical Impedance Spectroscopy to Distinguish Cancer from Normal Tissues with a Four Electrode Terminal Setup.pdf | Verlags-PDF | 1,58 MB | Adobe PDF | View/Open![]() |
Page view(s)
173
Last Week
1
1
Last month
8
8
checked on Jun 7, 2023
Download(s)
104
checked on Jun 7, 2023
SCOPUSTM
Citations
1
Last Week
0
0
Last month
0
0
checked on Jul 11, 2022
Google ScholarTM
Check
Note about this record
Cite this record
Export
This item is licensed under a Creative Commons License