Now showing1 - 3 of 3
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: with files ,
    Local analysis of micro mixing for the Villermaux-Dushman protocol by using the imaging UV-Vis spectroscopy
    (Elsevier, 2024-05-01) ; ;
    Grabellus, Markus
    ;
    Le, Xuan My
    ;
    The Villermaux-Dushman protocol with UV-Vis analytics is an established tool to characterize the global micro mixing performance in process equipment. The local mixing process is described by a micro mixing model (incorporation model), originally designed for turbulent flows. The novel imaging UV-Vis spectroscopy used in this work uncovers locally resolved micro mixing phenomena in a laminar split-and-recombine (SAR) mixer unit manufactured from selective laser-induced etching (SLE). The local absorbance is recorded with a high spatial resolution camera through a telecentric lens and post-processed into local concentration fields of components. The method unveils discrepancies of the micro mixing time determined from the conventional incorporation model in laminar flow and the locally recorded mixing process. The micro mixing time rather needs to be seen as a mean micro mixing time instead. Furthermore, the spatial information obtained by the imaging UV-Vis spectroscopy gives insight into local micro mixing and selectivity, yielding new approaches to equipment optimization.
    Publicationtype: Journal Article
      54  412
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: with files ,
    A novel approach for visualizing mixing phenomena of reactive liquid-liquid flows in milli- and micro-channels
    (Frontiers Media S.A., 2022-06-06) ; ; ; ;
    Modular milli- and micro-structured systems represent a promising approach to exploit the potential of micro-process technology, including precise reaction control and scale-up. A major drawback of micro-structured devices is fouling and mixing mechanisms need to be investigated phenomenologically to better understand the processes that lead to fouling. Previous work was conducted to resolve 3D concentration fields by means of Laser-Induced Fluorescence (LIF) using a Confocal Laser Scanning Microscope (CLSM) (Frey et al., J Flow Chem, 2021, 11, 599–609). While the CLSM-LIF method yields detailed insight into concentration fields down to a few micrometers, it is limited to stationary flow structures only. Aubin et al. (Chemical Engineering Science, 2010, 65, 2065–2093) give a comprehensive review of methods to analyze mixing behavior. Most recent optical measurement methods rely on the detection of a single compound in mixtures. In case of reactive mixing, Tthe state of the art procedures to locally visualize micro mixing relies on tracking a reaction product which forms on molecular scale. In literature, only small micro-structures are manufactured from transparent materials, however larger milli-structures often lack optical accesses with sufficient quality. Selective laser-induced etching (SLE) is a new technique which enables the fabrication of larger milli-structures in transparent materials that are relevant for industry-scale applications. This work develops a method based on a concept of Kexel et al. (Chemie Ingenieur Technik, 2021, 93, 830–837) visualizing the selectivity of a competitive-consecutive gas-liquid reaction in a Taylor bubble flow. The main goal of this work is the analysis of the absorbance spectra of bromothymol blue (BTB) at different pH values in a miscible liquid-liquid system in a fused silica split-and-recombine mixer. The milli-structure of the mixer is manufactured by means of SLE. Backlight at different wavelengths is pulsed matching the recording frequency. In contrast to conventional UV/Vis setups, the absorbance is recorded locally within the mixer. The proposed method yields the 2D concentration distribution of multiple species with high spatial resolution. The spatially resolved reactant and product distribution unveils micro mixing and can yield important information about local root causes of fouling.
    Publicationtype: Journal Article
    Scopus© Citations 1  149  527
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: with files ,
    CFD analysis of asymmetric mixing at different inlet configurations of a split-and-recombine micro mixer
    In the scope of the ENPRO II initiative (Energy Efficiency and Process Intensification for the Chemical Industry), a major challenge of process intensification of polymer synthesis in continuous systems is fouling. Pre-mixing is a key aspect to prevent fouling and is achieved through milli and micro structured devices (Bayer et al. 1). While equal volume flow ratios are well investigated in milli and micro systems, asymmetric mixing tasks have received less attention. This paper investigates the dependency of mixing phenomena on different flow rate ratios and modified inlet geometries. A split-and-recombine (SAR) mixer is modified by means of an injection capillary to facilitate the asymmetric mixing task. Asymmetric volume flows of ratios between 1:15 and 1:60 are investigated; the velocity ratios range from 0.5 to 2. The setup is simulated with the Computational Fluid Dynamics (CFD) tool ANSYS®; Fluent. The species equation is solved directly without the use of micro mixing models. The simulation is validated by means of a concentration field in a mixing Tee using Laser-Induced Fluorescence (LIF) with a Confocal Laser Scanning Microscope (CLSM). The three dimensional flow structures and the mixing quality are analyzed as a measure for micro mixing. The calculated concentration fields show good agreement with the experimental results and reveal the secondary flow structures and chaotic advection within the channel. The injection of the small feed stream is found to be very efficient when drawn into the secondary structures, increasing the potential of diffusive mixing. CFD simulations help to understand and locate such structures and improve the mixing performance.
    Publicationtype: Journal Article
    Scopus© Citations 2  150  153