6 results
Now showing1 - 6 of 6
- Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: with files , BrainLossNet : a fast, accurate and robust method to estimate brain volume loss from longitudinal MRI(Springer, 2024-06-16); ; ; ; Purpose: MRI-derived brain volume loss (BVL) is widely used as neurodegeneration marker. SIENA is state-of-the-art for BVL measurement, but limited by long computation time. Here we propose “BrainLossNet”, a convolutional neural network (CNN)-based method for BVL-estimation. Methods: BrainLossNet uses CNN-based non-linear registration of baseline(BL)/follow-up(FU) 3D-T1w-MRI pairs. BVL is computed by non-linear registration of brain parenchyma masks segmented in the BL/FU scans. The BVL estimate is corrected for image distortions using the apparent volume change of the total intracranial volume. BrainLossNet was trained on 1525 BL/FU pairs from 83 scanners. Agreement between BrainLossNet and SIENA was assessed in 225 BL/FU pairs from 94 MS patients acquired with a single scanner and 268 BL/FU pairs from 52 scanners acquired for various indications. Robustness to short-term variability of 3D-T1w-MRI was compared in 354 BL/FU pairs from a single healthy men acquired in the same session without repositioning with 116 scanners (Frequently-Traveling-Human-Phantom dataset, FTHP). Results: Processing time of BrainLossNet was 2–3 min. The median [interquartile range] of the SIENA-BrainLossNet BVL difference was 0.10% [− 0.18%, 0.35%] in the MS dataset, 0.08% [− 0.14%, 0.28%] in the various indications dataset. The distribution of apparent BVL in the FTHP dataset was narrower with BrainLossNet (p = 0.036; 95th percentile: 0.20% vs 0.32%). Conclusion: BrainLossNet on average provides the same BVL estimates as SIENA, but it is significantly more robust, probably due to its built-in distortion correction. Processing time of 2–3 min makes BrainLossNet suitable for clinical routine. This can pave the way for widespread clinical use of BVL estimation from intra-scanner BL/FU pairs.Publicationtype: Journal Article8 11 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: without files , Infratentorial lesions in multiple sclerosis patients: intra- and inter-rater variability in comparison to a fully automated segmentation using 3D convolutional neural networks(Springer, 2022-04); ; ; ; Objective: Automated quantification of infratentorial multiple sclerosis lesions on magnetic resonance imaging is clinically relevant but challenging. To overcome some of these problems, we propose a fully automated lesion segmentation algorithm using 3D convolutional neural networks (CNNs). Methods: The CNN was trained on a FLAIR image alone or on FLAIR and T1-weighted images from 1809 patients acquired on 156 different scanners. An additional training using an extra class for infratentorial lesions was implemented. Three experienced raters manually annotated three datasets from 123 MS patients from different scanners. Results: The inter-rater sensitivity (SEN) was 80% for supratentorial lesions but only 62% for infratentorial lesions. There was no statistically significant difference between the inter-rater SEN and the SEN of the CNN with respect to the raters. For supratentorial lesions, the CNN featured an intra-rater intra-scanner SEN of 0.97 (R1 = 0.90, R2 = 0.84) and for infratentorial lesion a SEN of 0.93 (R1 = 0.61, R2 = 0.73). Conclusion: The performance of the CNN improved significantly for infratentorial lesions when specifically trained on infratentorial lesions using a T1 image as an additional input and matches the detection performance of experienced raters. Furthermore, for infratentorial lesions the CNN was more robust against repeated scans than experienced raters. Key Points: • A 3D convolutional neural network was trained on MRI data from 1809 patients (156 different scanners) for the quantification of supratentorial and infratentorial multiple sclerosis lesions. • Inter-rater variability was higher for infratentorial lesions than for supratentorial lesions. The performance of the 3D convolutional neural network (CNN) improved significantly for infratentorial lesions when specifically trained on infratentorial lesions using a T1 image as an additional input. • The detection performance of the CNN matches the detection performance of experienced raters.Publicationtype: Journal Article80 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: with files , Fully automated longitudinal segmentation of new or enlarged multiple sclerosis lesions using 3D convolutional neural networks(Elsevier, 2020-09-24); ; ; ; The quantification of new or enlarged lesions from follow-up MRI scans is an important surrogate of clinical disease activity in patients with multiple sclerosis (MS). Not only is manual segmentation time consuming, but inter-rater variability is high. Currently, only a few fully automated methods are available. We address this gap in the field by employing a 3D convolutional neural network (CNN) with encoder-decoder architecture for fully automatic longitudinal lesion segmentation. Input data consist of two fluid attenuated inversion recovery (FLAIR) images (baseline and follow-up) per patient. Each image is entered into the encoder and the feature maps are concatenated and then fed into the decoder. The output is a 3D mask indicating new or enlarged lesions (compared to the baseline scan). The proposed method was trained on 1809 single point and 1444 longitudinal patient data sets and then validated on 185 independent longitudinal data sets from two different scanners. From the two validation data sets, manual segmentations were available from three experienced raters, respectively. The performance of the proposed method was compared to the open source Lesion Segmentation Toolbox (LST), which is a current state-of-art longitudinal lesion segmentation method. The mean lesion-wise inter-rater sensitivity was 62%, while the mean inter-rater number of false positive (FP) findings was 0.41 lesions per case. The two validated algorithms showed a mean sensitivity of 60% (CNN), 46% (LST) and a mean FP of 0.48 (CNN), 1.86 (LST) per case. Sensitivity and number of FP were not significantly different (p < 0.05) between the CNN and manual raters. New or enlarged lesions counted by the CNN algorithm appeared to be comparable with manual expert ratings. The proposed algorithm seems to outperform currently available approaches, particularly LST. The high inter-rater variability in case of manual segmentation indicates the complexity of identifying new or enlarged lesions. An automated CNN-based approach can quickly provide an independent and deterministic assessment of new or enlarged lesions from baseline to follow-up scans with acceptable reliability.Publicationtype: Journal ArticleScopus© Citations 36 136 330 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: without files , Multiple sclerosis lesion activity segmentation with attention-guided two-path CNNsMultiple sclerosis is an inflammatory autoimmune demyelinating disease that is characterized by lesions in the central nervous system. Typically, magnetic resonance imaging (MRI) is used for tracking disease progression. Automatic image processing methods can be used to segment lesions and derive quantitative lesion parameters. So far, methods have focused on lesion segmentation for individual MRI scans. However, for monitoring disease progression, lesion activity in terms of new and enlarging lesions between two time points is a crucial biomarker. For this problem, several classic methods have been proposed, e.g., using difference volumes. Despite their success for single-volume lesion segmentation, deep learning approaches are still rare for lesion activity segmentation. In this work, convolutional neural networks (CNNs) are studied for lesion activity segmentation from two time points. For this task, CNNs are designed and evaluated that combine the information from two points in different ways. In particular, two-path architectures with attention-guided interactions are proposed that enable effective information exchange between the two time point's processing paths. It is demonstrated that deep learning-based methods outperform classic approaches and it is shown that attention-guided interactions significantly improve performance. Furthermore, the attention modules produce plausible attention maps that have a masking effect that suppresses old, irrelevant lesions. A lesion-wise false positive rate of 26.4% is achieved at a true positive rate of 74.2%, which is not significantly different from the interrater performance.Publicationtype: Journal Article183 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: without files , Fully automated longitudinal segmentation of new or enlarging multiple sclerosis (MS) lesions using 3D convolutional neural networks(Urban & Vogel, 2019-10); ; ; ; Publicationtype: Conference Paper145 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: without files , Fully automated lesion segmentation using heavily trained 3D convolutional neural networks are equivalent to manual expert segmentations(Sage Publications, 2019); ; ; ; Publicationtype: Conference Poster not in Proceedings171