Item type:Publication, Access status: without files , Stresses and deformations of an osteosynthesis plate in a lateral tibia plateau fracture(2022-01-01); ; ; ; This study has the aim to investigate the strain and stress in an anterolateral locking plate applied for the fixation of a lateral split fracture. To simulate a complex fracture situation, three segments were separated. With a FEM analysis, representative places for strain and stress measurement were determined. A locked osteosynthesis plate was instrumented with strain gauges and tested on a fractured and a non-fractured Saw Bone model. To simulate different loading situations, four different points of force application, from the center of the condyles to a 15 mm posterior position, were used with a medial-lateral load distribution of 60:40. The simulations as well as the biomechanical tests demonstrated that two deformations dominate the load on the plate: a bending into posterior direction and a bulging of the plate head. Shifting the point of application to the posterior direction resulted in increasing maximum stress, from 1.16 to 6.32 MPa (FEM analysis) and from 3.04 to 7.00 MPa (biomechanical study), respectively. Furthermore, the comparison of the non-fractured and fractured models showed an increase in maximum stress by the factor 2.06-2.2 (biomechanical investigation) and 1.5-3.3 (FEM analysis), respectively.Publicationtype: Journal ArticleScopus© Citations 2 47 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: without files , Biomechanical aspects of the posteromedial split in bicondylar tibial plateau fractures—a finite-element investigationPurpose: To gain principal insight into fixation techniques of a posteromedial split fragment in bicondylar tibial plateau fractures. Methods: A computer simulation was performed, applying the finite-element method (FEM) to compare four methods of fixation of the posteromedial split fragment: lateral plate (model 1), lateral plate and kickstand screw (model 2), lateral plate and two antero-posterior lag screws (model 3), and lateral and posteromedial plate (model 4). The displacement of the fragment and material stresses in implants and bone under 2500 N axial load were analyzed. Results: Maximal displacement of the posteromedial split fragment of 2.8 mm was found with a sole lateral plate. An added kickstand screw decreased the displacement to 1.46 mm. Added lag screws improved stability by a factor 4, with a maximal displacement of 0.76 mm. The double-plate configuration revealed 0.27 mm, a decrease of the displacement by a factor 10 compared to model 1. An additional analysis of posteromedial fragment displacements with osteoporotic bone, simulated by dividing the elastic modulus of the bone by a factor 2, turned out to be of relevant impact. For model 1, the calculations did not converge. The influence of bone quality was found to be 70% in model 2, 60% in model 3, and 40% in model 4. Conclusions: The results indicate that the additional fixation of a posteromedial split fracture by plate osteosynthesis might be advantageous in bicondylar tibial plateau fractures treated with lateral plating. This might be even more important in patients with low bone quality.Publicationtype: Journal Article109 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: without files , Ausriss von All-suture-Ankern verursacht geringere Knochenschäden und ist von der Kortikalisdicke abhängig [All-suture anchor pullout results in decreased bone damage and depends on cortical thickness](2020-09-01); ; ; ; Purpose: To evaluate the influence of cortical and cancellous bone structure on the biomechanical properties of all-suture and conventional anchors and compare the morphological bone damage after their failure. The hypothesis of the study is that all-suture anchor pullout is less invasive and that the pullout force is influenced by the cortical thickness. Methods: Thirty human humeri were biomechanically tested as follows starting with a load cycle from 20 to 50 N, a stepwise increase of the upper peak force by 0.05 N for each cycle at a rate of 1 Hz was performed. Analysis included maximum pullout strength for three different anchor implantation angles (45°, 90°, 110°) of the two anchor types. After anchor pullout, every sample underwent micro-CT analysis. Bone mineral density (BMD) and cortical thickness were determined at the anchor implantation site. Furthermore, the diameter of the cortical defect and the volume of the bone cavity were identified. Results: The maximum pullout strength of all-suture anchors demonstrates a strong correlation to the adjacent cortical thickness (r = 0.82, p ≤ 0.05) with at least 0.4 mm needed to withstand 200 N. No correlation could be seen in conventional anchors. Moreover, no correlation could be detected for local BMD in both anchors. All-suture anchors show a significantly narrower cortical defect as well as a smaller bone cavity following pullout (4.3 ± 1.3 mm vs. 5.3 ± 0.9 mm, p = 0.037; 141 mm3 vs. 212 mm3; p = 0.009). The cortical defect is largest if the anchors are placed at a 45° angle. Conclusion: In contrast to conventional anchors, the pullout force of all-suture anchors depends on the thickness of the humeral cortex. Furthermore, all-suture anchors show a significantly smaller cortical defect as well as decreased bone damage in the case of pullout. Therefore, the clinical implication of this study is that all-suture anchors are advantageous due to their bone preserving ability. Also, intraoperative decortication should not be performed and cortical thickness should be preoperatively evaluated to decrease the risk of anchor failure.Publicationtype: Journal Article119 1 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: without files , Biomechanical analysis of conventional anchor revision after all-suture anchor pullout: a human cadaveric shoulder model(2019-12); ; ; ; Hypothesis and background: The possibility of implanting a conventional anchor at the pullout site following all-suture anchor failure was evaluated in a biomechanical cadaveric model. The hypothesis of the study was that anchor revision would yield equal biomechanical properties. Methods: Ten human humeri were obtained, and bone density was determined via computed tomography. After all-suture anchor (n = 5) and conventional 4.5-mm anchor (n = 5) insertion, biomechanical testing was conducted. Following all-suture anchor pullout, a conventional 5.5-mm anchor was inserted at the exact site of pullout (n = 5) and biomechanical testing was reinitiated. Testing was conducted using an initial preload of 20 N, followed by an unlimited cyclic protocol, with a stepwise increasing force of 0.05 N for each cycle at a rate of 1 Hz until system failure. The number of cycles, maximum load to failure, stiffness, displacement, and failure mode, as well as macroscopic observation at the failure site including diameter, shape, and cortical destruction, were registered. Results: The defect following all-suture pullout showed a mean diameter of 4 mm, and conventional revision was possible in each sample. There was no significant difference between the initial all-suture anchor implantation and the conventional anchor implantation or the conventional revision following all-suture failure regarding mean pullout strength, stiffness, displacement, or total number of cycles until failure. Conclusion: Conventional anchor revision at the exact same site where all-suture anchor pullout occurred is possible and exhibits similar biomechanical properties.Publicationtype: Journal Article187