Item type:Publication, Access status: without files , Experimental characterization of the biaxial mechanical properties of porcine gastric tissue(Elsevier, 2017-10); ; ; ; Health problems related to the stomach are among the most important sources of morbidity in industrialized countries. There is evidence that mechanics may play an important role in various such pathologies. However, so far experimental data characterizing the mechanical properties of gastric tissue remain scarce, which significantly limits our understanding of the mechanics of the stomach. To help close this gap, we performed biaxial mechanical tests of porcine gastric tissue patches. Our experiments reveal a considerable anisotropy and different mechanical properties in the three major regions of the stomach (fundus, corpus, antrum). Moreover, they demonstrate that the mechanical properties of the gastric wall and the physiological function of the different regions of the stomach are closely related. This finding suggests that further examination of the mechanics of the gastric wall may indeed be a promising avenue of research towards a better understanding of the organic causes of frequent health problems related to the stomach.Publicationtype: Journal Article15 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: without files , The evolution of radiation dose over time : measurement of a patient cohort undergoing whole-body examinations on three computer tomography generationsObjectives To evaluate and compare the radiation dose and image quality of whole-body-CT (WBCT) performed on the 3rd-generation dual-source-CT (DSCT) with 2nd-generation DSCT and 64-slices-Single-Source-CT (SSCT) in a large patient cohort. Material and methods Using a monitoring and tracking software 1451, 747 and 1861 patients scanned with a one-spiral-thorax-abdomen-pelvis-CT-examination on a 3rd-, 2nd-generation DSCT and SSCT, respectively, were extracted from the PACS server. For the intra-individual analysis, 203 patients on the 3rd-generation DSCT were identified. Out of those 203 patients, 155 had the same examination on the 2nd-generation DSCT, 91 patients had the same examination on the SSCT and 43 patients had an examination on all three CT-generations. Automatic tube current modulation was active on all three CT-generations, whereas automatic tube voltage selection was only available on both DSCT-generations. Dose was recorded by the size-specific-dose-estimate-method (SSDE); signal-to-noise-ratio (SNR) and contrast-to-noise-ratio (CNR) were calculated placing a ROI on the ascending aorta/liver and the subcutaneous adipose tissue at comparable level. Image quality of axillary and mediastinal lymph nodes and adrenal glands was assessed by two experienced radiologists. Results Subjective image quality was excellent throughout all three CT-generations (p = 0.38–0.98). Quantitative image quality in both DSCT generations was superior to SSCT (p < 0.001). SNR and CNR in the liver parenchyma were superior in the 3rd-generation DSCT compared to the 2nd generation DSCT (p < 0.001), whereas there was no difference in the aorta. In the inter-individual analysis, CTDIvol was lower by 26.9% and 44.3% in the 3rd-generation DSCT, when compared to the 2nd-generation DSCT and SSCT, respectively; SSDE was lower by 31.5% and 51% in the 3rd-generation DSCT, when compared to the 2nd-generation DSCT and SSCT, respectively. In the intra-individual comparison CTDIVol in the 3rd-generation DSCT was lower by 33% and 45%, when compared to the 2nd-gneration DSCT and the SSCT, respectively. Consequently, SSDE in the 3rd-generation DSCT was lower by 29% and by 43% when compared to the 2nd-generation DSCT and SSCT, respectively. Conclusion State-of-the-art CT-equipment substantially reduce radiation dose without affecting image quality.Publicationtype: Journal Article9