Now showing1 - 5 of 5
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Re-revision risk of modular and monobloc revision stems after revision total hip arthroplasty
    (British Editorial Society of Bone and Joint Surgery, 2024-08-19) ;
    Wu, Y.
    ;
    ; ;
    Michel, M.
    Implant fracture of modular revision stems is a major complication after total hip arthroplasty revision (rTHA). Studies looking at specific modular designs report fracture rates of 0.3% to 0.66% whereas fractures of monobloc designs are only reported anecdotally. It is unclear whether the overall re-revision rate of modular designs is higher and if, whether stem fractures or other revision reasons are responsible for this elevation. All revisions within 5 years after implantation of a revision stems (n0=13,900; n5=2506) were analysed using Cox regression with design (modular: n=17, monobloc: n=27), BMI, Sex and Elixhauser Score as independent variables. One stage and two stage revisions were analysed separately (1-stage: modular n= 7,102; monobloc n= 4,542; 2-stage: 1,551 / 704). The revision volume of the hospitals was also considered (low: <20 revisions, medium: 21–50 revisions, high: >50 revisions). For the 1-stage revisions, the re-revision risk after 4 years was 14,3% [13.2%, 15.5%] for monobloc and 17.4% [16.40%, 18.40%] for modular stems (p< 0.001). Stem fracture was the reason for re-revision in 2.4% of the modular (fracture rate 0.42%) and 0.6% of the monobloc revisions. The difference in re-revision rates between the designs was mainly due to differences in dislocation and stem loosening. For the 2-stage revisions, the revision risks for either design were similar (21.7% [18,5%, 25.4%] vs. 23.0% [20.8%, 25.4%]; p=0.05). Patient characteristics influenced the comparison between the two designs in the 1-stage group but very little in the 2-stage group. Modular revision stem fractures only contribute very minor to re-revision risk. In 2-stage revisions, no difference in overall re-revision rates between designs was observed. This might indicate that the differences observed for 1-stage procedures are due to differences between the patient cohorts, not reflected by the parameters available or surgeon choice.
    Publicationtype: Conference Paper
      16
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Standard- und Spezialinlays in primärer Hüftendoprothetik : Aktuelle Studien- und Umfrageergebnisse aus dem Endoprothesenregister Deutschland (EPRD)
    BACKGROUND: Instability constitutes the main reason for revision hip arthroplasties. Modified polyethylene liners are designed to improve the stability of a hip replacement. In July 2022 The Bone & Joint Journal published a study with data of the German Arthroplasty Registry (EPRD). The study investigated mechanical failure of standard and modified liner designs in primary, cementless total hip arthroplasty. Following the study, the EPRD conducted a survey of German clinics to research the utilization of lipped liners in primary total hip replacement. METHODS: The liner study included 151,096 primary, elective, cementless total hip arthroplasties. Data from November 2012 to November 2020 were obtained from the EPRD. Standard polyethylene liners were compared with lipped, angulated, offset and angulated/offset inlays. Cumulative incidences for endpoint revision due to mechanical complication were calculated with a competing risk analysis. The influence of other variables was investigated with a multivariate Cox regression. In the following online survey, 237 out of 789 hospitals completed a form. RESULTS AND CONCLUSION: In our analysis, only offset liners were, compared to standard liners, associated with a reduced risk of mechanical failure in a short to medium follow up. However, the resultant joint reaction force is increased with offset liners due to the lateralization of the hip center of rotation. Thus, the long-term performance of offset liners needs to be observed. Our survey indicated that lipped liners were implanted more often if the posterior approach was used. Moreover, lipped liners were mostly positioned with the elevated rim in the biomechanically less optimal posterior-superior quadrant. To improve stability it is suggested to position the elevated rim in the posterior-inferior quadrant.
    Publicationtype: Journal Article
      22
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Endoprothesenregister Deutschland (EPRD) : Jahresbericht 2023
    (EPRD Deutsche Endoprothesenregister gGmbH, 2023) ; ; ; ;
    Publicationtype: Book
      138
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Modified acetabular component liner designs are not superior to standard liners at reducing the risk of revision : an analysis of 151,096 cementless total hip arthroplasties from the German Arthroplasty Registry
    AIMS: Registry studies on modified acetabular polyethylene (PE) liner designs are limited. We investigated the influence of standard and modified PE acetabular liner designs on the revision rate for mechanical complications in primary cementless total hip arthroplasty (THA). METHODS: We analyzed 151,096 primary cementless THAs from the German Arthroplasty Registry (EPRD) between November 2012 and November 2020. Cumulative incidence of revision for mechanical complications for standard and four modified PE liners (lipped, offset, angulated/offset, and angulated) was determined using competing risk analysis at one and seven years. Confounders were investigated with a Cox proportional-hazards model. RESULTS: Median follow-up was 868 days (interquartile range 418 to 1,364). The offset liner design reduced the risk of revision (hazard ratio (HR) 0.68 (95% confidence interval (CI) 0.50 to 0.92)), while the angulated/offset liner increased the risk of revision for mechanical failure (HR 1.81 (95% CI 1.38 to 2.36)). The cumulative incidence of revision was lowest for the offset liner at one and seven years (1.0% (95% CI 0.7 to 1.3) and 1.8% (95% CI 1.0 to 3.0)). No difference was found between standard, lipped, and angulated liner designs. Higher age at index primary THA and an Elixhauser Comorbidity Index greater than 0 increased the revision risk in the first year after surgery. Implantation of a higher proportion of a single design of liner in a hospital reduced revision risk slightly but significantly (p = 0.001). CONCLUSION: The use of standard acetabular component liners remains a good choice in primary uncemented THA, as most modified liner designs were not associated with a reduced risk of revision for mechanical failure. Offset liner designs were found to be beneficial and angulated/offset liner designs were associated with higher risks of revision.
    Publicationtype: Journal Article
    Scopus© Citations 3  23
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Factors influencing periprosthetic femoral fracture risk
    AIMS: Periprosthetic femoral fractures (PPF) are a serious complication of total hip arthroplasty (THA) and are becoming an increasingly common indication for revision arthroplasty with the ageing population. This study aimed to identify potential risk factors for PPF based on an analysis of registry data. METHODS: Cases recorded with PPF as the primary indication for revision arthroplasty in the German Arthroplasty Registry (Endoprothesenregister Deutschland (EPRD)), as well as those classified as having a PPF according to the International Classification of Diseases (ICD) codes in patients' insurance records were identified from the complete datasets of 249,639 registered primary hip arthroplasties in the EPRD and included in the analysis. RESULTS: The incidence of PPFs was higher (24.6%; 1,483) than reported in EPRD annual reports listing PPF as the main reason for revision (10.9%; 654). The majority of fractures occurred intraoperatively and were directly related to the implantation process. Patients who were elderly, female, or had comorbidities were at higher risk of PPFs (p < 0.001). German hospitals with a surgical volume of < 300 primary procedures per year had a higher rate of PPFs (p < 0.001). The use of cemented and collared prostheses had a lower fracture risk PPF compared to uncemented and collarless components, respectively (both p < 0.001). Collared prostheses reduced the risk of PPF irrespective of the fixation method and hospital's surgical volume. CONCLUSION: The high proportion of intraoperative fractures emphasises the need to improve surgeon training and surgical technique. Registry data should be interpreted with caution because of potential differences in coding standards between institutions.
    Publicationtype: Journal Article
      63