2 results
Filters
Settings
Now showing1 - 2 of 2
- Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: with files , Fretting-Korrosion modularer Hüftendoprothesen(2017); Early failure of total hip replacements can be caused by the release of wear products from modular junctions due to fretting-corrosion. The aim was to identify design factors that make the analyzed tapers susceptible to wear and corrosion. A quantitative analysis of wear from circular and flat taper designs for a mixed metal coupling (CoCr-TMZF) was performed. Based on the reconstruction of explanted taper geometries, individual engagement properties are determined, providing an estimate of the contact situation at the taper interface in-vivo. This mechanical approach gave explanations of the arrangement of local wear phenomena at the taper interface.Publicationtype: Doctoral Thesis718 490 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: with files , Primary hip replacement stem taper fracture due to corrosion in 3 patients(Taylor & Francis, 2016-11-06); ; ; ; Publicationtype: Journal ArticleScopus© Citations 14 269 438