Item type:Publication, Access status: with files , Cortical threaded pedicle screw improves fatigue strength in decreased bone quality(Springer, 2021); ; ; ; Purpose: Inadequate anchoring of pedicle screws in vertebrae with poor bone quality is a major problem in spine surgery. The aim was to evaluate whether a modified thread in the area of the pedicle could significantly improve the pedicle screw fatigue strength. Methods: Fourteen human cadaveric vertebral bodies (L2 and L3) were used for in vitro testing. Bone density (BMD) was determined by quantitative computed tomography. Vertebral bodies were instrumented by standard pedicle screws with a constant double thread on the right pedicle and a partial doubling of the threads–quad thread–(cortical thread) in the area of the pedicle on the left pedicle. Pulsating sinusoidal, cyclic load (0.5 Hz) with increasing peak force (100 N + 0.1 N/cycles) was applied orthogonal to the screw axis. The baseline force remained constant (50 N). Fatigue test was terminated after exceeding 5.4-mm head displacement (~ 20° screw tilting). Results: The mean fatigue load at failure was 264.9 N (1682 cycles) for the standard screws and was increased significantly to 324.7 N (2285 cycles) by the use of cortical threaded screws (p = 0.014). This effect is particularly evident in reduced BMD (standard thread 241.2 N vs. cortical thread 328.4 N; p = 0.016), whereas in the group of vertebrae with normal BMD no significant difference could be detected (standard thread 296.5 N vs. cortical thread 319.8 N; p = 0.463). Conclusions: Compared to a conventional pedicle screw, the use of a cortical threaded pedicle screw promises superior fatigue load in vertebrae with reduced bone quality.Publicationtype: Journal ArticleScopus© Citations 7 266 189 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: with files , Reduced cement volume does not affect screw stability in augmented pedicle screws(Springer, 2020-03-23); ; ; ; Purpose: Cement augmentation of pedicle screws is able to improve screw anchorage in osteoporotic vertebrae but is associated with a high complication rate. The goal of this study was to evaluate the impact of different cement volumes on pedicle screw fatigue strength. Methods: Twenty-five human vertebral bodies (T12–L4) were collected from donors between 73 and 97 years of age. Bone density (BMD) was determined by quantitative computed tomography. Vertebral bodies were instrumented by conventional pedicle screws, and unilateral cement augmentation was performed. Thirteen vertebrae were augmented with a volume of 1 ml and twelve with a volume of 3 ml bone cement. A fatigue test was performed using a cranial–caudal sinusoidal, cyclic load (0.5 Hz) with increasing compression force (100 N + 0.1 N/cycles). Results: The load to failure was 183.8 N for the non-augmented screws and was increased significantly to 268.1 N (p < 0.001) by cement augmentation. Augmentation with 1 ml bone cement increased the fatigue load by 41% while augmentation with 3 ml increased the failure load by 51% compared to the non-augmented screws, but there was no significant difference in fatigue loads between the specimens with screws augmented with 1 ml and screws augmented with 3 ml of bone cement (p = 0.504). Conclusion: Cement augmentation significantly increases pedicle screw stability. The benefit of augmentation on screw anchorage was not significantly affected by reducing the applied volume of cement from 3 ml to 1 ml. Considering the high risk of cement leakage during augmentation, we recommend the usage of a reduced volume of 1 ml bone cement for each pedicle screw. Graphic Abstract: These slides can be retrieved under Electronic Supplementary Material [Figure not available: see fulltext.].Publicationtype: Journal ArticleScopus© Citations 12 211 221 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: without files , Time to augment?! Impact of cement augmentation on pedicle screw fixation strength depending on bone mineral density(2018-08-01); ; ; ; Cement augmentation of pedicle screws is known to increase their mechanical strength. Aim was to evaluate the impact of cement augmentation on pedicle screw fatigue strength in dependence of the bone mineral density (BMD).Publicationtype: Journal Article127 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: without files , Insufficient stability of pedicle screws in osteoporotic vertebrae: biomechanical correlation of bone mineral density and pedicle screw fixation strength(2017-11-01); ; ; ; Purpose: Loosening of pedicle screws is one major complication of posterior spinal stabilisation, especially in the patients with osteoporosis. Augmentation of pedicle screws with cement or lengthening of the instrumentation is widely used to improve implant stability in these patients. However, it is still unclear from which value of bone mineral density (BMD) the stability of pedicle screws is insufficient and an additional stabilisation should be performed. The aim of this study was to investigate the correlation of bone mineral density and pedicle screw fatigue strength as well as to define a threshold value for BMD below which an additional stabilisation is recommended. Methods: Twenty-one human T12 vertebral bodies were collected from donors between 19 and 96 years of age and the BMD was measured using quantitative computed tomography. Each vertebral body was instrumented with one pedicle screw and mounted in a servo-hydraulic testing machine. Fatigue testing was performed by implementing a cranio-caudal sinusoidal, cyclic (0.5 Hz) load with stepwise increasing peak force. Results: A significant correlation between BMD and cycles to failure (r = 0.862, r2 = 0.743, p < 0.001) as well as for the linearly related fatigue load was found. Specimens with BMD below 80 mg/cm3 only reached 45% of the cycles to failure and only 60% of the fatigue load compared to the specimens with adequate bone quality (BMD > 120 mg/cm3). Conclusions: There is a close correlation between BMD and pedicle screw stability. If the BMD of the thoracolumbar spine is less than 80 mg/cm3, stability of pedicle screws might be insufficient and an additional stabilisation should be considered.Publicationtype: Journal Article147 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: without files , Influence of the screw augmentation technique and a diameter increase on pedicle screw fixation in the osteoporotic spine : pullout versus fatigue testing(Springer, 2014-09-27); ; ; ; Purpose: For posterior spinal stabilization, loosening of pedicle screws at the bone-screw interface is a clinical complication, especially in the osteoporotic population. Axial pullout testing is the standard pre-clinical testing method for new screw designs although it has questioned clinical relevance. The aim of this study was to determine the fixation strength of three current osteoporotic fixation techniques and to investigate whether or not pullout testing results can directly relate to those of the more physiologic fatigue testing.Publicationtype: Journal Article4 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: without files , Biomechanical advantage of C1 pedicle screws over C1 lateral mass screws : a cadaveric study(Springer, 2013-12-31); ; ; ; Purpose: The established technique for posterior C1 screw placement is via the lateral mass. Use of C1 monocortical pedicle screws is an emerging technique which utilizes the bone of the posterior arch while avoiding the paravertebral venous plexus and the C2 nerve root. This study compared the relative biomechanical fixation strengths of C1 pedicle screws with C1 lateral mass screws. Methods: Nine human C1 vertebrae were instrumented with one lateral mass screw and one pedicle screw. The specimens were subjected to sinusoidal, cyclic (0.5 Hz) fatigue loading. Peak compressive and tensile forces started from ±25 N and constantly increased by 0.05 N every cycle. Testing was stopped at 5 mm displacement. Cycles to failure, displacement, and initial and end stiffness were measured. Finally, CT scans were taken and the removal torque measured. Results: The pedicle screw technique consistently and significantly outperformed the lateral mass technique in cycles to failure (1,083 ± 166 vs. 689 ± 240 cycles), initial stiffness (24.6 ± 3.9 vs. 19.9 ± 3.2 N/mm), end stiffness (16.6 ± 2.7 vs. 11.6 ± 3.6 N/mm) and removal torque (0.70 ± 0.78 vs. 0.13 ± 0.09 N m). Only 33 % of pedicle screws were loose after testing compared to 100 % of lateral mass screws. Conclusions: C1 pedicle screws were able to withstand higher toggle forces than lateral mass screws while maintaining a higher stiffness throughout and after testing. From a biomechanical point of view, the clinical use of pedicle screws in C1 is a promising alternative to lateral mass screws. © 2013 Springer-Verlag.Publicationtype: Journal ArticleScopus© Citations 43 38 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: without files , Does the cement stiffness affect fatigue fracture strength of vertebrae after cement augmentation in osteoporotic patients?(Springer, 2013-05-16); ; ; ; Purpose: Normal progression of osteoporosis or the rigid reinforcement of the fractured vertebral body with polymethyl methacrylate (PMMA) cement is being discussed as a cause for adjacent-level fractures after vertebroplasty. The purpose of this study was to investigate whether augmentation with low stiffness cement can decrease the risk of adjacent-level fractures in low-quality bone. Methods: Eighteen female osteoporotic lumbar specimens (L1-L5) were harvested and divided into three groups according to bone mineral density: (I) native; (II) PMMA; (III) modified PMMA (lower stiffness). For the PMMA and modified PMMA groups, a compression fracture was first mechanically induced in L3, and then the fracture received vertebroplasty treatment. The cement stiffness reduction of the modified PMMA group was achieved via an addition of 8 mL of serum to the typical PMMA base. All specimens were exposed to cyclic loading (4 Hz) and a stepwise increasing applied peak force. Cement stiffness was tested according to ISO 5833. Results: A 51 % decrease in cement stiffness was achieved in the modified PMMA group (954 ± 141 vs. 1,937 ± 478 MPa, p < 0.001). Fatigue fracture force (the force level during cyclic loading at which the deformation experienced a sudden increase; FFF) was significantly affected by bone quality (r 2 = 0.39, p = 0.006) and by the initial fracture force (the force necessary to create the initial fracture in L3 prior to augmentation; r 2 = 0.82, p < 0.001). Using initial fracture force as a covariate, the FFF of the modified PMMA group (1,764 ± 49 N) was significantly higher than in the PMMA group (1,544 ± 55 N; p = 0.03). Conclusions: A possible method to reduce adjacent-level fractures after vertebroplasty in patients with reduced bone quality could be the use of a lower modulus cement. Therefore, mixing cement with biocompatible fluids could prove useful to tailor cement properties in the operating theater.Publicationtype: Journal Article55 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: without files , Biomechanical analysis of expansion screws and cortical screws used for ventral plate fixation on the cervical spineCompared to bicortical screws, the surgical risk of injuring intraspinal structures can be minimized with the use of monocortical screws. However, this reduction should not be achieved at the expense of the stability of the fixation. With monocortical stabilization, the expansion screws have the potential of absorbing high loads. Therefore, they are expected to be a suitable alternative to bicortical screws for revision surgeries and in osteoporotic bone. The purpose of this in vitro study was to investigate the stiffness of the two screw-plate systems used for ventral stabilization of the cervical spine, by focusing on the suitability of expansion screws as tools for revision treatments. The study was conducted in ten functional units of human cervical spines. The device sample stiffness was determined for four conditions using a turning moment of 2.25 N m each around one of the three principle axes. The conditions were native, destabilized, primarily stabilized with one of the screw-plate systems, followed by secondary stabilization using the expansion screw implant. The stabilized samples achieved a comparable, in most cases higher stiffness than the native samples. The samples undergoing secondary stabilization using expansion screws tend to display greater stiffness for all three axes compared to the primarily stabilized samples. The achieved tightening moment of the screws was higher than the one achieved with primary fixation. Both plates revealed similar primary stability. Revision surgeries with secondary instrumentation achieve a high stiffness of the screwed up segments. Monocortical expansion screws combined with a trapezoidal plate allow ventral stabilization of the cervical spine that is comparable to the plate fixation using bicortical screws.Publicationtype: Journal Article4