Item type:Publication, Access status: with files , Acromioclavicular joint suture button repair leads to coracoclavicular tunnel wideningPurpose: Biomechanical evaluation of three different suture button devices used in acromioclavicular joint repair and analysis of their effect on post-testing tunnel widening. Methods: Eighteen human shoulder girdles were assigned into three groups with a similar mean bone mineral density. Three different single-tunnel acromioclavicular repair devices were tested: (1) AC TightRope® with FiberWire; (2) AC Dog Bone™ Button with FiberTape; (3) Low Profile AC Repair System. Biomechanical testing was performed simulating the complex movement of the distal clavicle as follows. A vertical load of 80 N was applied continuously. The rotation of the clavicle about its long axis was set at 10° anterior and 30° posterior for 2500 cycles at 0.25 Hz. The horizontal translation of the clavicle was set at 6 mm medial and 6 mm lateral for 10,000 cycles at 1 Hz. The coracoclavicular distance was measured before and after testing. After testing, each sample underwent micro-CT analysis. Following 3D reconstruction, the area of the bone tunnels was measured at five defined cross sections. Results: In TightRope® and Dog Bone™ groups, all samples completed testing, whereas in the Low Profile group, three out of six samples showed system failure. The mean absolute difference of coracoclavicular distance after testing was significantly greater in the Low Profile group compared to TightRope® and Dog Bone™ groups (4.3 ± 1.3 mm vs 1.9 ± 0.7 mm vs 1.9 ± 0.8 mm; p = 0.001). Micro-CT analysis of the specimens demonstrated significant tunnel widening in the inferior clavicular and superior coracoid regions in all three groups (p < 0.05). Conclusion: Significant tunnel widening can be observed for all devices and is primarily found in the inferior parts of the clavicle and superior parts of the coracoid. The Low Profile AC Repair System showed inferior biomechanical properties compared to the AC TightRope® and AC Dog Bone™ devices. Therefore, clinicians should carefully select the type of acromioclavicular repair device used and need to consider tunnel widening as a complication.Publicationtype: Journal ArticleScopus© Citations 5 58 136 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: with files , All-suture anchor pullout results in decreased bone damage and depends on cortical thickness(Springer, 2021-07); ; ; ; Purpose: To evaluate the influence of cortical and cancellous bone structure on the biomechanical properties of all-suture and conventional anchors and compare the morphological bone damage after their failure. The hypothesis of the study is that all-suture anchor pullout is less invasive and that the pullout force is influenced by the cortical thickness. Methods: Thirty human humeri were biomechanically tested as follows: starting with a load cycle from 20 to 50 N, a stepwise increase of the upper peak force by 0.05 N for each cycle at a rate of 1 Hz was performed. Analysis included maximum pullout strength for three different anchor implantation angles (45°, 90°, 110°) of the two anchor types. After anchor pullout, every sample underwent micro-CT analysis. Bone mineral density (BMD) and cortical thickness were determined at the anchor implantation site. Furthermore, the diameter of the cortical defect and the volume of the bone cavity were identified. Results: The maximum pullout strength of all-suture anchors demonstrates a strong correlation to the adjacent cortical thickness (r = 0.82, p ≤ 0.05) with at least 0.4 mm needed to withstand 200 N. No correlation could be seen in conventional anchors. Moreover, no correlation could be detected for local BMD in both anchors. All-suture anchors show a significantly narrower cortical defect as well as a smaller bone cavity following pullout (4.3 ± 1.3 mm vs. 5.3 ± 0.9 mm, p = 0.037; 141 mm3 vs. 212 mm3; p = 0.009). The cortical defect is largest if the anchors are placed at a 45° angle. Conclusion: In contrast to conventional anchors, the pullout force of all-suture anchors depends on the thickness of the humeral cortex. Furthermore, all-suture anchors show a significantly smaller cortical defect as well as decreased bone damage in the case of pullout. Therefore, the clinical implication of this study is that all-suture anchors are advantageous due to their bone preserving ability. Also, intraoperative decortication should not be performed and cortical thickness should be preoperatively evaluated to decrease the risk of anchor failure.Publicationtype: Journal ArticleScopus© Citations 23 180 156 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: without files , Acromioclavicular joint dislocations: coracoclavicular reconstruction with and without additional direct acromioclavicular repair(2017-07-01); ; ; ; Purpose: To evaluate different stabilisation techniques for acromioclavicular (AC) joint separations, including direct AC repair, and to compare the properties of the stabilised and native joints. Methods: An established in vitro testing model for the AC joint was used to analyse joint stability after surgical reconstruction [double TightRope (DTR), DTR with AC repair (DTR + AC), single TR with AC repair (TR + AC), and PDS sling with AC repair (PDS + AC)]. Twenty-four human cadaveric shoulders were randomised by age into four testing groups. Joint stiffness was measured by applying an axial load during defined physiological ranges of motion. Similar tests were performed for the native joints, after dissecting the coracoclavicular and AC ligaments, and after surgical reconstruction. Cyclic loading was performed for 1000 cycles with 20–70 N and vertical load to failure determined after cyclic testing. Results: Axial stiffness for all TR groups was significantly higher than for the native joint (DTR 38.94 N/mm, p = 0.005; DTR + AC 37.79 N/mm, p = 0.015; TR + AC 45.61 N/mm, p < 0.001 vs. native 26.05 N/mm). The axial stiffness of the PDS + AC group was similar to that of the native joint group (21.4 N/mm, n.s.). AC repair did not significantly influence rotational stiffness. Load to failure was similar and >600 N in all groups (n.s.). Conclusion: Reconstruction of AC dislocations with one or two TRs leads to stable results with a higher stiffness than the native joints. For the PDS + AC group, axial stiffness was similar to the native situation, although there might be a risk of elongation. Direct AC repair showed no significantly increased stability in comparison with reconstructions without direct AC repair. Thus, a direct AC repair seems to be dispensable in clinical practice, while TRs or PDS cerclages appear to provide sufficiently stable results.Publicationtype: Journal Article164