Item type:Publication, Access status: without files , Significance of clinical examination, CT and MRI scan in the diagnosis of posterior pelvic ring fractures(Elsevier, 2014-10-22); ; ; ; Patients with a fracture in the anterior pelvic ring often simultaneously demonstrate pain in the posterior pelvic ring. The aim of the present prospective study was to assess the sensitivity of CT, MRI and clinical examination in the detection of fractures in the posterior pelvic ring in patients with fractures of the anterior pelvic ring diagnosed in conventional radiographs. Methods: Sixty patients with radiographic signs of an anterior pelvic ring injury were included in this prospective analysis. Following a focused clinical examination of the posterior pelvis, all patients underwent both a CT and then a MRI scan of their pelvis. Two board certified radiologists evaluated the CT and MRI scans independently. To estimate the presence of osteoporosis the Hounsfield units of the vertebral body of L5 were measured in each case. Results: Fifty-three women and seven men, with a mean age of 74.7 +/- 15.6 years were included into the study. A fracture of the posterior pelvic ring was found in fourty-eight patients (80%) patients using MRI. Fractures of the posterior pelvic ring would have been missed in eight cases (17%), if only CT had been used. Eighty-five percent of the patients with a posterior fracture had an osteoporosis. The majority of the cases suffered from a low energy trauma. Thirty-eight patients (83%) with positive clinical signs at the posterior pelvic ring actually had a fracture of the posterior pelvic ring in the MRI. The clinical examination proved to be equally effective to CT in detecting posterior pelvic ring fractures. Conclusion: The significance of both, clinical examination and CT was confirmed in the detection of fractures in the posterior pelvic ring. MRI examination of the pelvis however, was found to be superior in detecting undislocated fractures in a cohort of patients with a high incidence of osteoporosis. Using MRI may be beneficial in select cases, especially when reduced bone density is suspected.Publicationtype: Journal ArticleScopus© Citations 63 35 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: without files , Cement augmentation of the proximal femoral nail antirotation for the treatment of osteoporotic pertrochanteric fractures : a biomechanical cadaver study(Elsevier, 2013-03-29); ; ; ; Introduction Proximal femoral fractures will gain increasing importance in the future due to the epidemiological development. Osteoporosis is often a limiting factor in the achievement of implant stability. New nailing systems offer the possibility of augmentation of the femoral neck component with cement. The aim of this study was to perform a biomechanical comparison of implant stability in osteoporotic pertrochanteric fractures using the proximal femoral nail antirotation (PFNA, Synthes GmbH, Umkirch, Germany) with cement augmented and non-augmented blades. Materials and methods Bone mineral density (BMD) was measured by dual-energy X-ray absorptiometry (DEXA) in six pairs of fresh-frozen human femurs. Standardised pertrochanteric fractures (AO31-A2.3) were treated with a PFNA. Cement augmentation was performed in six constructs. Axial loading was applied according to a single-leg-stance model using a hydraulic testing machine increasing to 1400 N over 10,000 cycles. Biomechanical comparisons between the two groups that were comparable concerning BMD, tip-apex-distance and native stiffness were made with regard to postoperative stiffness, survived cycles, load to failure, failure mechanism and axial displacement. Results The stiffness of all stabilised femurs was significantly lower than for native specimens (native 702.5 ± 159.6 N/mm vs. postoperative 275.4 ± 53.8 N/mm, p < 0.001). Stiffness after instrumentation was significantly greater for the cement augmented group than for the non-augmented group (300.6 ± 46.7 N/mm vs. 250.3 ± 51.6 N/mm, respectively, p = 0.001). Five of the twelve constructs survived cyclic testing. Statistically significant differences of the BMD were detected between survived and failed constructs (0.79 ± 0.17 g/cm2 vs. 0.45 ± 0.12 g/cm2, respectively, p = 0.028). The failure loads for specimens surviving 10,000 cycles were 4611.9 ± 2078.9 N in the cement augmented group (n = 3) and 4516.3 N and 3253.5 N in the non-augmented group (n = 2). Postoperative stiffness was found to be a positive predictor of maximum force to failure (R2 = 0.83, p = 0.02). Conclusions The results of this biomechanical study show that cement augmentation of the PFNA increases the implant stability in osteoporotic pertrochanteric fractures. Further studies are necessary to evaluate this procedure in providing long term clinical results.Publicationtype: Journal Article47 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: without files , Locking plate fixation of humeral head fractures with a telescoping screw : a comparative biomechanical study versus a standard plate(Elsevier, 2012-06-01) ;Gradl, Gertraud ;Stedtfeld, Hans Werner; ; Objectives: Locking plate fixation of humeral head fractures bares the risk of glenohumeral screw penetration. In order to circumvent this problem it is recommended to insert shorter locking screws having at least a 6 mm distance to the humeral head cortex. This in turn may reduce fixation stability and may lead to early varus displacement. One second frequent failure mechanism is cranial displacement of the greater tubercle. The study evaluates the biomechanical properties of a locking plate employing an additional telescoping screw that may enhance resistance to varus displacement. Screw in screw fixation of the greater tubercle may reduce the rate of cranial displacement. Methods: In four paired fresh-frozen human cadaver humeri (age > 70 years) a Neer IV/3 fracture was created with a 5 mm osteotomy gap simulating metaphyseal comminution. Limbs were randomly assigned to receive plate fixation with an additional telescoping screw (Humerus Tele Screw: HTS) and on the contralateral limb Philos plate fixation before biomechanical evaluation (MTS-Bionix 858.2). Standard locking screws were placed in both groups 6 mm below the radiological head circumference; the telescoping screw was placed in the subchondral layer. The greater tubercle was fixed with an additional screw in both techniques, in the HTS group the screw was anchored in the sleeve of the telescrew (screw in screw fixation). Findings: Fixation stability with a mean stiffness of 300.9 ± 28.8 N/mm in the HTS plate group proved to be significantly higher than in the Philos plate group (184.2 ± 23.4 N/mm; p = 0.006). The HTS plate also resisted higher loads in terms of fixation failure with loss of reduction at 290 ± 58.6 N in comparison to 205 ± 8.6 N for the Philos plate (p = 0.2). Displacement of the greater tubercle occurred in no case of the HTS plate group and in two out of four cases in the Philos plate group. Interpretation: The HTS plate provides high fixation stability in an in vitro humeral head fracture model and securely prevents displacement of the greater tubercle.Publicationtype: Journal Article6