Item type:Publication, Access status: with files , Additive manufactured versus traditional osteosynthesis plates : a finite element analysis(Infinite Science Publishing, 2022-09-12); ; ; ; Additive Manufacturing (AM) is rapidly gaining acceptance in healthcare. Due to 3D printing of polyetheretherketone (PEEK) constructions almost any complex geometry, e. g. bio-mimicking implants or light-weight hollow implant bodies, can be produced. In this paper a direct comparison between PEEK and titanium osteosynthesis plates is achieved with a finite element analysis. By that, pros and cons of PEEK as implant material are discussed and different use cases are identified. For the comparison a generic osteosynthesis plate for diaphysis is designed. The exceeding of the yield strength even at low bending and torsional loads highlights the problems that occur when applying PEEK implants at locations which are affected by moderate mechanical loads. Since fracture stabilisation is the main function of osteosynthesis plates, stiffness is a highly relevant property of these. Therefore, a direct exchange of titanium to PEEK would increase the risk of non-union. Thus, a different structure or an improved material, e. g. carbon fibre PEEK composite, is required for loaded locations to replace metallic implants.Publicationtype: Journal Article42 60 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: without files , Stresses and deformations of an osteosynthesis plate in a lateral tibia plateau fracture(2022-01-01); ; ; ; This study has the aim to investigate the strain and stress in an anterolateral locking plate applied for the fixation of a lateral split fracture. To simulate a complex fracture situation, three segments were separated. With a FEM analysis, representative places for strain and stress measurement were determined. A locked osteosynthesis plate was instrumented with strain gauges and tested on a fractured and a non-fractured Saw Bone model. To simulate different loading situations, four different points of force application, from the center of the condyles to a 15 mm posterior position, were used with a medial-lateral load distribution of 60:40. The simulations as well as the biomechanical tests demonstrated that two deformations dominate the load on the plate: a bending into posterior direction and a bulging of the plate head. Shifting the point of application to the posterior direction resulted in increasing maximum stress, from 1.16 to 6.32 MPa (FEM analysis) and from 3.04 to 7.00 MPa (biomechanical study), respectively. Furthermore, the comparison of the non-fractured and fractured models showed an increase in maximum stress by the factor 2.06-2.2 (biomechanical investigation) and 1.5-3.3 (FEM analysis), respectively.Publicationtype: Journal ArticleScopus© Citations 2 47 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: without files , An Electronic Osteosynthesis Implant for Continuous Load Monitoring using a Strain GaugeThe utilization of strain gauges for monitoring the applied mechanical load to osteosynthesis plates using electronic implants was reported several times in literature. The technique was found to provide valuable information for monitoring the fracture healing process and for improving the rehabilitation. This paper introduces a new electronic osteosynthesis implant, which uses supercapacitors as an energy storage for short term autonomous operation. Moreover, a bluetooth low energy (BLE) transceiver is integrated into the system, which covers larger distances and is less sensitive to misalignment than the commonly used inductive data transmission. This improves the usability of the proposed system for the patients. The system can continuously sample and transmit strain values at a sampling rate of 5 Hz for more than 10 min without being recharged. More than 60 cm of distance in any practically relevant direction can be covered by the BLE data transmission if the implant is placed 5 cm deep in a phantom. The implant dimensions of 20 mm x 16 mm still fit on osteosynthesis plates for larger bones.Publicationtype: Conference Paper48