6 results
Now showing1 - 6 of 6
- Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: with files , Automated isocenter optimization approach for treatment planning for gyroscopic radiosurgery(Wiley, 2023-08-13); ; ; ; Background: Radiosurgery is a well-established treatment for various intracranial tumors. In contrast to other established radiosurgery platforms, the new ZAP-X® allows for self-shielding gyroscopic radiosurgery. Here, treatment beams with variable beam-on times are targeted towards a small number of isocenters. The existing planning framework relies on a heuristic based on random selection or manual selection of isocenters, which often leads to a higher plan quality in clinical practice. Purpose: The purpose of this work is to study an improved approach for radiosurgery treatment planning, which automatically selects the isocenter locations for the treatment of brain tumors and diseases in the head and neck area using the new system ZAP-X®. Methods: We propose a new method to automatically obtain the locations of the isocenters, which are essential in gyroscopic radiosurgery treatment planning. First, an optimal treatment plan is created based on a randomly selected nonisocentric candidate beam set. The intersections of the resulting subset of weighted beams are then clustered to find isocenters. This approach is compared to sphere-packing, random selection, and selection by an expert planner for generating isocenters. We retrospectively evaluate plan quality on 10 acoustic neuroma cases. Results: Isocenters acquired by the method of clustering result in clinically viable plans for all 10 test cases. When using the same number of isocenters, the clustering approach improves coverage on average by 31 percentage points compared to random selection, 15 percentage points compared to sphere packing and 2 percentage points compared to the coverage achieved with the expert selected isocenters. The automatic determination of location and number of isocenters leads, on average, to a coverage of 97 ± 3% with a conformity index of 1.22 ± 0.22, while using 2.46 ± 3.60 fewer isocenters than manually selected. In terms of algorithm performance, all plans were calculated in less than 2 min with an average runtime of 75 ± 25 s. Conclusions: This study demonstrates the feasibility of an automatic isocenter selection by clustering in the treatment planning process with the ZAP-X® system. Even in complex cases where the existing approaches fail to produce feasible plans, the clustering method generates plans that are comparable to those produced by expert selected isocenters. Therefore, our approach can help reduce the effort and time required for treatment planning in gyroscopic radiosurgery.Publicationtype: Journal Article13 19 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: with files , Towards fast adaptive replanning by constrained reoptimization for intra-fractional non-periodic motion during robotic SBRTBackground: Periodic and slow target motion is tracked by synchronous motion of the treatment beams in robotic stereotactic body radiation therapy (SBRT). However, spontaneous, non-periodic displacement or drift of the target may completely change the treatment geometry. Simple motion compensation is not sufficient to guarantee the best possible treatment, since relative motion between the target and organs at risk (OARs) can cause substantial deviations of dose in the OARs. This is especially evident when considering the temporally heterogeneous dose delivery by many focused beams which is typical for robotic SBRT. Instead, a reoptimization of the remaining treatment plan after a large target motion during the treatment could potentially reduce the actually delivered dose to OARs and improve target coverage. This reoptimization task, however, is challenging due to time constraints and limited human supervision. Purpose: To study the detrimental effect of spontaneous target motion relative to surrounding OARs on the delivered dose distribution and to analyze how intra-fractional constrained replanning could improve motion compensated robotic SBRT of the prostate. Methods: We solve the inverse planning problem by optimizing a linear program. When considering intra-fractional target motion resulting in a change of geometry, we adapt the linear program to account for the changed dose coefficients and delivered dose. We reduce the problem size by only reweighting beams from the reference treatment plan without motion. For evaluation we simulate target motion and compare our approach for intra-fractional replanning to the conventional compensation by synchronous beam motion. Results are generated retrospectively on data of 50 patients. Results: Our results show that reoptimization can on average retain or improve coverage in case of target motion compared to the reference plan without motion. Compared to the conventional compensation, coverage is improved from 87.83 % to 94.81 % for large target motion. Our approach for reoptimization ensures fixed upper constraints on the dose even after motion, enabling safer intra-fraction adaption, compared to conventional motion compensation where overdosage in OARs can lead to 21.79 % higher maximum dose than planned. With an average reoptimization time of 6 s for 200 reoptimized beams our approach shows promising performance for intra-fractional application. Conclusions: We show that intra-fractional constrained reoptimization for adaption to target motion can improve coverage compared to the conventional approach of beam translation while ensuring that upper dose constraints on VOIs are not violated.Publicationtype: Journal ArticleScopus© Citations 2 59 79 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: with files , AI-based optimization for US-guided radiation therapy of the prostateObjectives: Fast volumetric ultrasound presents an interesting modality for continuous and real-time intra-fractional target tracking in radiation therapy of lesions in the abdomen. However, the placement of the ultrasound probe close to the target structures leads to blocking some beam directions. Methods: To handle the combinatorial complexity of searching for the ultrasound-robot pose and the subset of optimal treatment beams, we combine CNN-based candidate beam selection with simulated annealing for setup optimization of the ultrasound robot, and linear optimization for treatment plan optimization into an AI-based approach. For 50 prostate cases previously treated with the CyberKnife, we study setup and treatment plan optimization when including robotic ultrasound guidance. Results: The CNN-based search substantially outperforms previous randomized heuristics, increasing coverage from 93.66 to 97.20% on average. Moreover, in some cases the total MU was also reduced, particularly for smaller target volumes. Results after AI-based optimization are similar for treatment plans with and without beam blocking due to ultrasound guidance. Conclusions: AI-based optimization allows for fast and effective search for configurations for robotic ultrasound-guided radiation therapy. The negative impact of the ultrasound robot on the plan quality can successfully be mitigated resulting only in minor differences.Publicationtype: Journal ArticleScopus© Citations 1 59 82 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: without files , Fast adaptive replanning by constrained reoptimization for intra-fractional non-periodic motion during SBRT of the prostatePublicationtype: Journal Article69 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: with files , Multicriterial CNN based beam generation for robotic radiosurgery of the prostate(De Gruyter, 2020-09-17); ; ; Although robotic radiosurgery offers a flexible arrangement of treatment beams, generating treatment plans is computationally challenging and a time consuming process for the planner. Furthermore, different clinical goals have to be considered during planning and generally different sets of beams correspond to different clinical goals. Typically, candidate beams sampled from a randomized heuristic form the basis for treatment planning. We propose a new approach to generate candidate beams based on deep learning using radiological features as well as the desired constraints. We demonstrate that candidate beams generated for specific clinical goals can improve treatment plan quality. Furthermore, we compare two approaches to include information about constraints in the prediction. Our results show that CNN generated beams can improve treatment plan quality for different clinical goals, increasing coverage from 91.2 to 96.8% for 3,000 candidate beams on average. When including the clinical goal in the training, coverage is improved by 1.1% points.Publicationtype: Journal ArticleScopus© Citations 1 156 161 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: with files , Feasibility and analysis of CNN-based candidate beam generation for robotic radiosurgeryPurpose: Robotic radiosurgery offers the flexibility of a robotic arm to enable high conformity to the target and a steep dose gradient. However, treatment planning becomes a computationally challenging task as the search space for potential beam directions for dose delivery is arbitrarily large. We propose an approach based on deep learning to improve the search for treatment beams. Methods: In clinical practice, a set of candidate beams generated by a randomized heuristic forms the basis for treatment planning. We use a convolutional neural network to identify promising candidate beams. Using radiological features of the patient, we predict the influence of a candidate beam on the delivered dose individually and let this prediction guide the selection of candidate beams. Features are represented as projections of the organ structures which are relevant during planning. Solutions to the inverse planning problem are generated for random and CNN-predicted candidate beams. Results: The coverage increases from 95.35% to 97.67% for 6000 heuristically and CNN-generated candidate beams, respectively. Conversely, a similar coverage can be achieved for treatment plans with half the number of candidate beams. This results in a patient-dependent reduced averaged computation time of 20.28%–45.69%. The number of active treatment beams can be reduced by 11.35% on average, which reduces treatment time. Constraining the maximum number of candidate beams per beam node can further improve the average coverage by 0.75 percentage points for 6000 candidate beams. Conclusions: We show that deep learning based on radiological features can substantially improve treatment plan quality, reduce computation runtime, and treatment time compared to the heuristic approach used in clinics.Publicationtype: Journal ArticleScopus© Citations 5 170 290