29 results
Filters
Settings
Now showing1 - 10 of 29
- Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: with files , The impact of mixed-anonymity on brainstorming performance: Evidence from field experiments(Public Library of Science (PLoS), 2026-07-21); ; Generating innovative and valuable ideas is essential for organizational competitiveness, and structured ideation formats are widely used to support creativity and idea generation of individuals, teams, and organizations. One such format is nominal brainstorming, in which participants generate ideas independently rather than through group interactions. Previous research has produced mixed results regarding the impact of anonymity in such individual idea-generation settings. Anonymous formats may reduce evaluation apprehension but can also lead to free riding, while non-anonymous formats promote accountability yet might increase the fear of negative evaluation. To clarify these conflicting findings, this study examines a novel mixed-anonymity approach in which participants generate ideas independently and anonymously, but the identities of those with the highest-rated ideas are subsequently revealed. We investigate the effects of mixed-anonymity on individually generated brainstorming outputs in two field experiments. The first adopts a between-subject design (N = 216), randomly assigning participants to anonymous, non-anonymous, or mixed-anonymity conditions. The second follows a within-subject design (N = 192), exposing each participant to all three conditions. In both studies, participants engaged in nominal brainstorming tasks. Ideation outcomes were measured by quantity, novelty, and user value. Additionally, we assessed evaluation apprehension and free riding as potential mediators. Our between-subject experiment did not demonstrate significant differences in idea quantity, novelty, or user value among the three anonymity conditions. Conversely, the within-subject experiment revealed significantly higher idea novelty under mixed-anonymity conditions compared to anonymous and non-anonymous conditions, but no significant effects on idea quantity or user value. Contrary to initial hypotheses, the proposed mediators, evaluation apprehension and free riding, did not explain these results. These findings refine the current understanding of anonymity in nominal brainstorming by showing that mixed-anonymity does not yield consistent effects across experimental settings. Overall, this study indicates that the role of mixed-anonymity in individual idea generation is contingent, not as straightforward as existing theorizing based on evaluation apprehension and free riding would suggest.Publicationtype: Journal Article23 13 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: with files , Fat quantification in dual-layer detector spectral CT: how to handle iron overload, varying tube voltage and radiation dose Indices(Public Library of Science (PLoS), 2024-05-23); ; ; ;Schubert, NiklasObjectives Opposed to other spectral CT techniques, fat quantification in dual-layer detector CT (dlCT) has only recently been developed. The impact of concomitant iron overload and dlCT-specific protocol settings such as the dose right index (DRI), a measure of image noise and tube current, on dlCT fat quantification was unclear. Further, spectral information became newly available <120 kV. Therefore, this study's objective was to evaluate the impact of iron, changing tube voltage, and DRI on dlCT fat quantification. Material and methods Phantoms with 0 and 8mg/cm3 iron; 0 and 5mg/cm3 iodine; 0, 10, 20, 35, 50, and 100% fat and liver equivalent, respectively, were scanned with a dlCT (CT7500, Philips, the Netherlands) at 100kV/20DRI, 120kV/20DRI, 140kV/20DRI, and at 120kV/16DRI, 120kV/24DRI. Material decomposition was done for fat, liver, and iodine (A1); for fat, liver, and iron (A2); and for fat, liver, and combined reference values of iodine and iron (A3). All scans were analyzed with reference values from 120kV/20DRI. For statistics, the intraclass correlation coefficient (ICC) and Bland-Altman analyses were used. Results In phantoms with iron and iodine, results were best for A3 with a mean deviation to phantom fat of 1.3±2.6% (ICC 0.999 [95%-confidence interval 0.996-1]). The standard approach A1 yielded a deviation of -2.5±3.0% (0.998[0.994-0.999]), A2 of 6.1±4.8% (0.991[0.974-0.997]). With A3 and changing tube voltage, the maximal difference between quantified fat and the phantom ground truth occurred at 100kV with 4.6±2.1%. Differences between scans were largest between 100kV and 140kV (2.0%[-7.1-11.2]). The maximal difference of changing DRI occurred between 16 and 24 DRI with 0.4%[-2.2-3.0]. Conclusion For dlCT fat quantification in the presence of iron, material decomposition with combined reference values for iodine and iron delivers the most accurate results. Tube voltage-specific calibration of reference values is advisable while the impact of the DRI on dlCT fat quantification is neglectable.Publicationtype: Journal Article5 84 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: without files , Spatial variations in the osteocyte lacunocanalicular network density and analysis of the connectomic parametersOsteocyte lacuno-canalicular network (LCN) is comprised of micrometre-sized pores and submicrometric wide channels in bone. Accumulating evidence suggests multiple functions of this network in material transportation, mechanobiological signalling, mineral homeostasis and bone remodelling. Combining rhodamine staining and confocal laser scanning microscopy, the longitudinal cross-sections of six mouse tibiae were imaged, and the connectome of the network was quantified with a focus on the spatial heterogeneities of network density, connectivity and length of canaliculi. In-vivo loading and double calcein labelling on these tibiae allowed differentiating the newly formed bone from the pre-existing regions. The canalicular density of the murine cortical bone varied between 0.174 and 0.243 μm/μm3, and therefore is three times larger than the corresponding value for human femoral midshaft osteons. The spatial heterogeneity of the network was found distinctly more pronounced across the cortex than along the cortex. We found that in regions with a dense network, the LCN conserves its largely tree-like character, but increases the density by including shorter canaliculi. The current study on healthy mice should serve as a motivating starting point to study the connectome of genetically modified mice, including models of bone diseases and of reduced mechanoresponse.Publicationtype: Journal Article11 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: with files , The force at the implant cannot be assessed by the mallet force - unless supported by a modelThe implantation of uncemented prostheses requires the application of sufficient forces to achieve a press-fit of the implant in the bone. Excessive forces have to be omitted to limit bone damage. Force measurements along the force transmission path between mallet and implant are frequently used to investigate this trade-off. Placing a load cell at a position of interest (PoI), which might be the implant bone interface or the head taper junction, is technically challenging or even impossible so that nearby positions are chosen. Thus, a certain inertia and stiffness remain between the PoI and the sensor, and consequently the measured dynamic forces differ from those at the PoI. This experimental and numerical study aimed to investigate the amount of force reduction along the transmission path while joining femoral heads to stem tapers. Forces were measured in vitro at the tip of the mallet, directly above the polymer tip of the impactor and below the stem taper. Springs and masses were used to represent the responding tissue of a patient. A semi-empirical numerical model of the force transmission path was developed and validated in order to simulate a larger range of responding tissue properties than experimentally possible and to investigate the influence of different surgical instruments. A distinct attenuation was observed since the peak forces at the impactor reached 35% of the applied peak forces and 21% at the stem taper, respectively. The force curves were replicated with a median root mean square error of 3.8% of the corresponding mallet blow for the impactor and 3.6% for the stem. The force measurement position and the used surgical instruments have a strong influence on the measured forces. Consequently, the exact measurement conditions with regard to sensor positioning and used surgical instruments have to be specified and hence only studies with similar setups should be compared to avoid misestimation of the forces at the PoI. The proposed dynamic numerical model is a useful tool to calculate the impact of the chosen or changed mechanical parameters prior to executing experiments and also to extrapolate the effect of changing the applied forces to the resulting forces at the PoI.Publicationtype: Journal Article17 57 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: with files , Small design modifications can improve the primary stability of a fully coated tapered wedge hip stem(Public Library of Science (PLoS), 2024-04-17); ; ; ; Increasing the stem size during surgery is associated with a higher incidence of intraoperative periprosthetic fractures in cementless total hip arthroplasty with fully coated tapered wedge stems, especially in femurs of Dorr type A. If in contrast a stem is implanted and sufficient primary stability is not achieved, such preventing successful osseointegration due to increased micromotions, it may also fail, especially if the stem is undersized. Stem loosening or periprosthetic fractures due to stem subsidence can be the consequence. The adaptation of an established stem design to femurs of Dorr type A by design modifications, which increase the stem width proximally combined with a smaller stem tip and an overall shorter stem, might reduce the risk of distal locking of a proximally inadequately fixed stem and provide increased stability. The aim of this study was to investigate whether such a modified stem design provides improved primary stability without increasing the periprosthetic fracture risk compared to the established stem design. The established (Corail, DePuy Synthes, Warsaw, IN, US) and modified stem designs (Emphasys, DePuy Synthes, Warsaw, IN, US) were implanted in cadaveric femur pairs (n = 6 pairs) using the respective instruments. Broaching and implantation forces were recorded and the contact areas between the prepared cavity and the stem determined. Implanted stems were subjected to two different cyclic loading conditions according to ISO 7206-4 using a material testing machine (1 Hz, 600 cycles@80 to 800 N, 600 cycles@80 to 1600 N). Translational and rotational relative motions between stem and femur were recorded using digital image correlation. Broaching and implantation forces for the modified stem were up to 40% higher (p = 0.024), achieving a 23% larger contact area between stem and bone (R2 = 0.694, p = 0.039) resulting in a four times lower subsidence during loading (p = 0.028). The slight design modifications showed the desired effect in this in-vitro study resulting in a higher primary stability suggesting a reduced risk of loosening. The higher forces required during the preparation of the cavity with the new broaches and during implantation of the stem could bare an increased risk for intraoperative periprosthetic fractures, which did not occur in this study.Publicationtype: Journal Article35 54 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: with files , The influence of hip revision stem spline design on the torsional stability in the presence of major proximal bone defects(Public Library of Science (PLoS), 2023-09-14); ; ; ; Background Despite the success of primary total hip arthroplasty, the number of revisions remains high. Infection, aseptic loosening, periprosthetic fractures and dislocations are the leading causes of hip revision. Current revision stem designs feature a tapered body with circumferential placed longitudinal thin metal splines that cut into the femoral cortex of the diaphysis to provide axial and rotational stability. Modifications to the spline design may help improve primary stability in various bone qualities. The purpose of this study was to evaluate whether the rotational stability of a revision hip stem can be improved by an additional set of less prominent, wider splines in addition to the existing set of splines. It is hypothesized that the additional splines will result in greater cortical contact, thereby improving torsional strength. Methods and findings The ultimate torsional strength of an established modular revision stem (Reclaim®, DePuy Synthes) was compared to a Prototype stem design with two sets of splines, differing in prominence by 0.25 mm. Five pairs of fresh-frozen human femurs (n = 10) were harvested and an extended trochanteric osteotomy was performed to obtain common bone defects in revision. Stems were implanted using successive droptower impacts to omit variability caused by mallet blows. The applied energy was increased from 2 J in 1 J increments until the planned implantation depth was reached or seating was less than 0.5 mm at 5 J impact. The ultimate torsional strength of the bone-to-implant interface was determined immediately after implantation. Image superposition was used to analyze and quantify the contact situation between bone and implant within the femoral canal. Cortical contact was larger for the Prototype design with the additional set of splines compared to the Reclaim stem (p = 0.046), associated with a higher torsional stability (35.2 ± 6.0 Nm vs. 28.2 ± 3.5 Nm, p = 0.039). Conclusions A second set of splines with reduced prominence could be shown to improve primary stability of a revision stem in the femoral diaphysis in the presence of significant proximal bone loss. The beneficial effect of varying spline size and number has the potential to further improve the longevity of revision hip stems.Publicationtype: Journal Article25 53 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: with files , Cost hierarchies and the pattern of product cost cross-subsidization: Extending a computational model of costing system designCost information is critical to ease managers’ decisions in daily business, but its provision is informationally demanding and error prone. Effective design choices for costing systems that can reduce errors are the subject of a growing body of research. The computational model by Anand, Balakrishnan, and Labro (2019) collates previous research in a unifying framework, turning it into a potential standard for future studies. This paper uses this framework and aims to investigate the mechanism behind the well-documented empirical pattern of product cost cross-subsidization in a large-scale simulation experiment. According to this pattern, volume-based costing systems bias the costs of high-volume products upward and of low-volume products downward. Although this pattern has important implications for firms and is discussed extensively in the literature, it has not yet been investigated with computational models. As the first objective of this paper, we replicate the original model by following a pattern-oriented model replication approach. The second objective is to study the mechanism behind the pattern of product cost cross-subsidization. We are unable to reproduce it systematically with the original model. However, the pattern emerges when we extend the model to include a simple cost hierarchy with distinct resource consumption types and volume- based cost drivers. This allows us to specify the likely mechanism behind it. Building on these results, we further extend the model with empirical and theory-based ABC cost hierarchies and assess their effect on product cost cross-subsidization. Our results suggest that production environments underpin more diverse cost hierarchies in practice than previously implemented in the model. Overall, we argue that our extension provides relevant insights into the pattern of product cost cross-subsidization, while our replication and extension strengthen the models’ credibility and usability for future research.Publicationtype: Journal ArticleScopus© Citations 1 30 75 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: with files , Does familiarity with an idea bias its evaluation?(Public Library of Science (PLoS), 2023-07-01); ; Although many organizations strive for radical or disruptive new ideas, many fall short of their goals. We propose that a primary reason for this failure is rooted in the individuals responsible for innovation: while they seek novel ideas, they prefer familiar ones. While prior research shows that individuals are biased against ideas with high objective novelty, it has overlooked the role of subjective novelty, i.e., the extent to which an idea is novel or unfamiliar to an individual idea evaluator. In this paper, we investigate how such subjective familiarity with an idea shapes idea evaluation in innovation. Drawing on research from psychology and marketing on the mere exposure effect, we argue that familiarity with an idea positively affects the evaluation’s outcome. We present two field studies and one laboratory study that support our hypothesis. This study contributes to the understanding of cognitive biases that affect innovation processes.Publicationtype: Journal Article76 70 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: with files , Novel synthetic clot analogs for in-vitro stroke modelling(Public Library of Science (PLoS), 2022-09-09); ; ; ; Purpose The increased demand for training of mechanical thrombectomy in ischemic stroke and development of new recanalization devices urges the creation of new simulation models both for training and device assessment. Clots properties have shown to play a role in procedural planning and thrombectomy device effectiveness. In this study, we analyzed the characteristics and applicability of completely synthetic, animal-free clots in the setting of an invitro model of mechanical thrombectomy for training and device assessment. Methods Synthetic clots based on agarose (n = 12) and silicone (n = 11) were evaluated in an in-vitro neurointervention simulation of mechanical thrombectomy with clot extraction devices. Calcified clots of mixed nature were simulated with addition of 3D printed structures. 9 clots were excluded due to insufficient vessel occlusion and failure to integrate with clot extraction device. Synthetic thrombi were characterized and compared using a categorical score-system on vessel occlusion, elasticity, fragmentation, adherence and device integration. Results Both agarose-based and silicone-based clots demonstrated relevant flow arrest and a good integration with the clot extraction device. Silicone-based clots scored higher on adherence to the vessel wall and elasticity. Conclusion Selected synthetic clots can successfully be implemented in an in-vitro training environment of mechanical thrombectomy. The clots' different properties might serve to mimic fibrin-rich and red blood cell-rich human thrombi.Publicationtype: Journal ArticleScopus© Citations 1 54 85 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: with files , Evaluation of the orally administered calcium alginate aerogel on the changes of gut microbiota and hepatic and renal function of Wistar rats(Public Library of Science (PLoS), 2021-04-28); ; ; ; The present study evaluates the effect of calcium alginate aerogel as a potential drug carrier, on the liver and kidney functions, and on the gut microbiota of Wistar rats. The studied alginate aerogel was prepared in the form of nanoparticles using the jet cutting technique, and they were characterized in terms of specific surface areas, outer morphology and particle size distribution. For the in vivo study, calcium alginate aerogel was administered orally, and liver and kidney functions were tested for one week and for four weeks in two distinct studies. During the short-term in vivo study, feces samples were collected for bacterial DNA extraction followed by 16S rRNA gene sequencing analyses to detect changes in gut microbiota. Results showed that the prepared alginate aerogel has an average BET-specific surface area of around 540 m /g, with a pore volume of 7.4 cc/g, and pore width of 30–50 nm. The in vivo study revealed that the levels of the studied kidney and liver enzymes didn’t exceed the highest level of the normal range. The study of gut microbiota showed different patterns; certain groups of bacteria, such as Clostridia and Bacteriodia, increased during the aerogels regime and continued to increase after the aerogel was stopped. While other groups such as Erysipelotrichia, and Candidatus saccharibacteria increased during aerogels treatment, and then decreased again after one month. Members of the Bacilli class showed a unique trend, that is, after being the most abundant group (63%) at time 0, their relative abundance decreased dramatically until it reached < 5%; which was the case even after stopping the aerogel treatment. 2Publicationtype: Journal ArticleScopus© Citations 10 147 135