4 results
Now showing1 - 4 of 4
- Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: with files , Characterization of the Synomag®-D-PEG-OMe nanoparticles for the encapsulation in human and murine red blood cells(Infinite Science Publishing, 2022-03-21); ; ; ; It was shown that the encapsulation of SPIO-based contrast agents in the red blood cells (RBCs) increases the circulation time in blood of these nanomaterials. Not all iron oxide particles are eligible for the entrapment into RBCs, depending on several factors and synthesis protocol. We have recently identified some type of nanoparticles that can be loaded with our method into RBCs to produce biocompatible SPIO-RBCs carriers that could be used as new intravascular tracers for biomedical applications, such as Magnetic Particle Imaging (MPI). Here, we report the first in vitro results obtained by using the Synomag®-D-PEG-OMe nanoparticles with both human and murine RBCs. MPS analysis showed that human Synomag®-D-PEG-OMe-loaded RBCs produced a signal that is weaker respect to the remarkable signal obtained with ferucarbotran loaded-RBCs prepared at the same condition, but it is to be noted that the encapsulation efficiency of Synomag®-D-PEG-OMe into cells is lower compared to ferucarbotran nanoparticles.Publicationtype: Journal ArticleScopus© Citations 1 62 191 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: with files , Encapsulation in human and murine erythrocytes of the Synomag®-D-PEG-OMe tracer for MPI application(Infinite Science Publishing, 2022); ; ; ; Recently, the potential of red blood cells (RBCs) loaded with superparamagnetic iron oxide (SPIO)-based nanoparti-cles as new blood-pool tracer material for the Magnetic Particle Imaging (MPI) has been investigated. It was shown that the encapsulation of SPIO-based contrast agents in the RBCs increase the circulation time in blood of these nanomaterials. However, not all iron oxide nanoparticles are eligible to the encapsulation into RBCs, depending on several factors such as dispersant agent nature, nanoparticle size and synthesis protocol. Therefore, we have recently started a program to identify those nanoparticles that can be potentially loaded with our method into RBCs. The goal is to produce biocompatible SPIO-RBCs carriers that can be used as new intravascular magnetic susceptible agents in biomedical applications, such as MRI and MPI. Here, we report the in vitro results obtained by using the Synomag®-D-PEG-OMe nanoparticle suspension (micromod Partikeltechnologie GmbH) with both human and murine red blood cells. MPS analysis showed that human Synomag®-D-PEG-OMe-loaded RBCs produced a signal that is weaker respect to the remarkable signal of ferucarbotran loaded-RBCs prepared at the same condition, but it is to be noted that the encapsulation efficiency of Synomag®-D-PEG-OMe into cells is lower compared to ferucarbotran nanoparticles.Publicationtype: Journal ArticleScopus© Citations 1 39 38 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: with files , Encapsulation of new MPI tracer nanoparticles in the human red blood cells(Infinite Science Publishing, 2020-09-02); ; ; ; Although Magnetic Particle Imaging (MPI) is not yet in clinical use, it is highly promising for several medical ap-plications, and especially for applications in diagnostic vascular in vivo imaging and imaging-guided vascular interventions. Furthermore, in the last years, different superparamagnetic iron oxide (SPIO) based contrast agents have been developed and approved for niche clinical applications in Magnetic Resonance Imaging (MRI) as alterna-tive to Gadolinium-based contrast agents (GBCAs) due to the risk for patients suffering from kidney dysfunction or nephrogenic systemic fibrosis (NSF). Recently, the potential of RBCs loaded with different SPIO nanoparticles as blood-pool tracer agents with longer blood retention time for MRI and MPI has been investigated. Here, we report the first in vitro results with the highly efficient dextran-based MPI tracer particles perimag® and synomag®-D to study their eligibility to be encapsulated into human RBCs and the potential of these new SPIO-RBC constructs as tracer material for MPI.Publicationtype: Journal ArticleScopus© Citations 3 70 113 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: without files , Development of long circulating magnetic particle imaging tracers: use of novel magnetic nanoparticles and entrapment into human erythrocytesAim: Magnetic particle imaging (MPI) is highly promising for biomedical applications, but optimal tracers for MPI, namely superparamagnetic iron oxide-based contrast agents, are still lacking. Materials & methods: The encapsulation of commercially available nanoparticles, specifically synomag®-D and perimag®, into human red blood cells (RBCs) was performed by a hypotonic dialysis and isotonic resealing procedure. The amounts of superparamagnetic iron oxide incorporated into RBCs were determined by Fe quantification using nuclear magnetic resonance and magnetic particle spectroscopy. Results: Perimag-COOH nanoparticles were identified as the best nanomaterial for encapsulation in RBCs. Perimag-COOH-loaded RBCs proved to be viable cells showing a good magnetic particle spectroscopy performance, while the magnetic signal of synomag-D-COOH-loaded RBCs dropped sharply. Conclusion: Perimag-COOH-loaded RBCs could be a potential tool for MPI diagnostic applications.Publicationtype: Journal Article178