Now showing1 - 10 of 83
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: with files ,
    Parameter estimation for model-based sensing of magneto-mechanical resonators
    Magneto-mechanical resonators (MMRs) represent a recently proposed type of passive sensor that enables the estimation of its pose as well as sensing other parameters in its environment. The working principle of MMRs entails an excitation of the sensors by oscillating magnetic fields, followed by a readout process facilitated by inductive receiver coils. The sensing technology relies on real-time parameter estimation. This encompasses the solution of a nonlinear inverse problem, with the induced signals and a suitable forward model as inputs. The aim of this paper is twofold: first, to introduce a reference model and simplified models for the MMR dynamics and inductive readout, and second, to provide robust and real-time capable methods to estimate themodel parameters. The effectiveness of the presented methods is evaluated in terms of their real-time potential, precision, and accuracy. All presented methods demonstrate the capacity to estimate the measured signal, with the simplified methods reducing the corresponding parameter estimation time by up to two orders of magnitude at the expense of less than 4% deviation for large maximum deflection angles.
    Publicationtype: Journal Article
      21  10
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: with files ,
    Randomized greedy Kaczmarz for multi-contrast magnetic particle imaging
    (Infinite Science Publishing, 2026-03-18) ; ; ; ;
    Multi-contrast magnetic particle imaging allows for separating signals from different tracer materials or microenvi-ronments from one joint measurement, yielding multi-channel images that distinguish tracers or encode properties such as temperature or viscosity. However, leakage artifacts enforce a noticeably longer application of iterative standard methods like the Kaczmarz algorithm to reach satisfactory reconstruction results. A greedy randomized version of the Kaczmarz method is adapted, showing the potential for faster recovery.
    Publicationtype: Journal Article
      16  9
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: with files ,
    Coordinate transformations for magnetic fields’ solid spherical harmonic coefficients
    (Infinite Science Publishing, 2026-03) ; ; ;
    Magnetic particle imaging fundamentally relies on magnetic fields, so accurate characterization of the fields is crucial for various applications, such as sequence planning or model-based reconstructions. Magnetic fields can be compactly represented by solid harmonic expansions, whose coefficients efficiently describe the field distribution. However, in practice, the coordinate systems of measurement devices are not always perfectly aligned with the scanner’s coordinate system, complicating direct comparison and integration of measured data from different setups. In this work, we present methods for transforming solid harmonic coefficients under translations, rotations, and point reflections. These transformations enable consistent mapping of field representations into a common coordinate system, allowing direct comparison of magnetic fields obtained in different coordinate frames.
    Publicationtype: Conference Paper
      10  15
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: with files ,
    Simulating Gadolinium-induced magnetic field variations for temperature sensing with magneto-mechanical resonators
    Small-size magneto-mechanical resonators (MMR) represent an emerging class of passive, wireless sensors that combine a sensing functionality with a tracking option. The operation principle is based on a resonating rotor oscillation whose frequency is defined by the magnetic flux density of a stator magnet. One general sensing mechanism is the coupling of an external parameter to this resonator frequency. In this study, we investigate an approach for encoding a temperature information as a shift in the natural oscillation frequency utilizing the temperature-dependent magnetic properties of gadolinium (Gd). We perform an isolated simulation study on the temperature scaling of the magnetic field generation for stators coated with Gd of varying thickness. Our results show that the magnetic phase transition of Gd at its Curie temperature leads to a pronounced change in the magnetic permeability enabling a significant magnetic shielding behavior only for lower temperatures. In the transition regime, we find a peak sensitivity reaching 45.8 Hz/K exceeding existing values from the literature by up to a factor of 20. The findings of this work are an important step toward quantitative high-sensitivity temperature extraction with MMRs.
    Publicationtype: Conference Paper
      95  45
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Discriminating nanoparticle core size using multi-contrast MPI
    (Jenny Stanford Publishing, 2026-01-01) ; ; ; ;
    Magnetic particle imaging (MPI) is an imaging modality that detects the response of a distribution of magnetic nanoparticle tracers to alternating magnetic fields. There has recently been exploration into multi-contrast MPI, in which the signal from different tracer materials or environments is separately reconstructed, resulting in multi-channel images that could enable temperature or viscosity quantification. In this work, we apply a multi-contrast reconstruction technique to discriminate between nanoparticle tracers of different core sizes. Three nanoparticle types with core diameters of 21.9 nm, 25.3 nm and 27.7 nm were each imaged at 21 different locations within the scanner field of view. Multi-channel images were reconstructed for each sample and location, with each channel corresponding to one of the three core sizes. For each image, signal weight vectors were calculated, which were then used to classify each image by core size. With a block averaging length of 10 000, the median signal-to-noise ratio was 40 or higher for all three sample types, and a correct prediction rate of 96.7% was achieved, indicating that core size can effectively be predicted using signal weight vector classification with close to 100% accuracy while retaining high MPI image quality. The discrimination of the core size was reliable even when multiple samples of different core sizes were placed in the measuring field.
    Publicationtype: Book Part
      4
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Detection and compensation of periodic motion in magnetic particle imaging
    (Jenny Stanford Publishing, 2026-01-01) ; ; ; ;
    The temporal resolution of the tomographic imaging method magnetic particle imaging (MPI) is remarkably high. The spatial resolution is degraded for measured voltage signal with low signal-tonoise ratio, because the regularization in the image reconstruction step needs to be increased for system-matrix approaches and for deconvolution steps in x-space approaches. To improve the signal-tonoise ratio, block-wise averaging of the signal over time can be advantageous. However, since block-wise averaging decreases the temporal resolution, it prevents resolving the motion. In this work, a framework for averaging motion-corrupted MPI raw data is proposed. The motion is considered to be periodic as it is the case for respiration and/or the heart beat. The same state of motion is thus reached repeatedly in a time series exceeding the repetition time of the motion and can be used for averaging. As the motion process and the acquisition process are in general not synchronized, averaging of the captured MPI raw data corresponding to the same state of motion requires to shift the starting point of the individual frames. For high-frequency motion, a higher frame rate is potentially required. To address this issue, a binning method for using only parts of complete frames from a motion cycle is proposed that further reduces the motion artifacts in the final images. The frequency of motion is derived directly from the MPI raw data signal without the need to capture an additional navigator signal. Using a motion phantom it is shown that the proposed method is capable of averaging experimental data with reduced motion artifacts. The methods are further validated on in-vivo data from mouse experiments to compensate the heart beat.
    Publicationtype: Book Part
      8
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: with files ,
    3D magnetic field camera with sub-second temporal resolution
    Accurate and efficient volumetric magnetic field measurements are essential for a wide range of applications. Conventional methods are often limited in terms of measurement speed and applicability, or suffer from scaling problems at larger volumes. This work presents a proof-of-concept field camera designed to measure magnetic fields within a spherical volume at a frame rate of 10 Hz. The camera features an array of 3D Hall magnetometers positioned according to a spherical t-design, allowing simultaneous magnetic field data acquisition from the surface of the sphere. The approach enables the efficient representation of all three components of the magnetic field inside the sphere using a sixth-degree polynomial, significantly reducing measurement time compared to sequential methods. This work details the design, calibration, and measurement methods of the field camera. To evaluate its performance, we compare it to a sequential single-sensor measurement by examining a magnetic gradient field. The obtained measurement uncertainties of approx. 1% demonstrate the feasibility of the approach and its potential applicability to a variety of future applications.
    Publicationtype: Journal Article
      23  19
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: with files ,
    Efficient measurement and representation of magnetic fields in tomographic imaging using ellipsoidal harmonics
    Given the pivotal role of magnetic fields in modern medicine, there is an increasing necessity for a precise characterization of their strength and orientation at high spatial and temporal resolution. As source-free magnetic fields present in tomographic imaging can be described by harmonic polynomials, they can be efficiently represented using spherical harmonic expansions, which allows for measurement at a small set of points on a sphere surrounding the field of view. However, the majority of closed-bore systems possess a cylindrical field of view, making a sphere an inadequate choice for coverage. Ellipsoids represent a superior geometrical choice, and the theory of ellipsoidal harmonic expansions can be applied to magnetic fields in an analogous manner. Despite the mathematical principles underpinning ellipsoidal harmonics being well-established, their utilization in practical applications remains relatively limited. In this study, we present an effective and flexible approach to measuring and representing magnetic fields present in tomographic imaging, which draws upon the theory of ellipsoidal harmonic expansions.
    Publicationtype: Journal Article
      27  18
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Uncertainties of a spherical magnetic field camera
    Spherical harmonic expansions are well-established tools for estimating magnetic fields from surface measurements and are widely used in applications such as tomographic imaging, geomagnetism, and biomagnetism. Although the mathematical foundations of these expansions are well understood, the impact of real-world imperfections, on the uncertainty of the field model has received little attention. In this work, we present a systematic uncertainty propagation analysis for a magnetic field camera that estimates the field from surface measurements using a spherical array of Hall magnetometers arranged in a spherical t-design. A Monte Carlo-based approach is employed to quantify how sensor-related uncertainties, such as calibration errors and positioning inaccuracies, affect the spatial distribution of the estimated field's uncertainty. The results offer insights into the robustness of spherical harmonic methods and help identify the dominant sources of uncertainty in practical implementations.
    Publicationtype: Conference Paper
      29
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: with files ,
    Natural frequency dependency of magneto-mechanical resonators on magnet distance
    The precise derivation of physical quantities like temperature or pressure at arbitrary locations is useful in numerous contexts, e.g. medical procedures or industrial process engineering. The novel sensor technology of magneto-mechanical resonators (MMR), based on the interaction of a rotor and stator permanent magnet, allows for the combined tracking of the sensor position and orientation while simultaneously sensing an external measurand. Thereby, the quantity is coupled to the torsional oscillation frequency, e.g. by varying the magnet distance. In this paper, we analyze the (deflection angle-independent) natural frequency dependency of MMR sensors on the rotor-stator distance, and evaluate the performance of theoretical models. The three presented sensors incorporate magnets of spherical and/or cylindrical geometry and can be operated at adjustable frequencies within the range of 61.9-307.3 Hz. Our proposed method to obtain the natural frequency demonstrates notable robustness to variations in the initial deflection amplitudes and quality factors resulting in statistical errors on the mean smaller than 0.05%. We find that the distance-frequency relationship is well described by an adapted dipole model accounting for material and manufacturing uncertainties. Their combined effect can be compensated by an adjustment of a single parameter which drives the median model deviation generally below 0.2%. Our depicted methods and results are important for the design and calibration process of new sensor types utilizing the MMR technique.
    Publicationtype: Journal Article
      61  53