3 results
Filters
Settings
Now showing1 - 3 of 3
- Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: without files , Resilienz gekoppelter EnergiesystemeThe problems of future energy systems with a high share of fluctuating renewable energies should not be underestimated. The difference between supply and demand for electrical energy has so far been covered by a high power reserve, which will not longer be possible in Germany after the coal and nuclear power plants are shut down in the next few years. In the following article, the concept of resilience will be explained in principle and the applicability of a resilience index will be discussed on the basis of an exemplary integrated energy system. Such an index is a possible method for quantifying the resilience of an energy system. In addition to the CO₂ emissions caused and the costs, the index is an additional criterion for evaluating energy system architectures."Publicationtype: Journal Article128 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: Restricted , Bewertung von Power-to-Gas-Anlagen mittels dynamischer SystemsimulationVia dynamic system simulation, the coupling of the high pressure gas grid of the city of Hamburg with the electricity grid is investigated. Therein, the technical potential of regenerative production, storage and feed-in of hydrogen into the gas grid is analyzed. The modeling approach is described. The frame of the scenario is given by the planned installed power of fluctuating renewable energies in 2050 and the electricity and gas demand in 2012. The electrolyzers are only operated when the residual load is negative. The simulation is performed for a whole year. Under consideration of a varying feed-in limit and varying electric power supply it is determined, how much surplus renewable work can be used and how much hydrogen can be fed into the grid. Finally, the CO2 reduction potential is evaluated. The results show, that a hydrogen buffer storage is necessary to achieve acceptable full load hours at high feed-in rates. In an annual balance, the CO2 emissions by reforming processes in Hamburg could be reduced by 11.5 % with over 3000 full load hours.Publicationtype: Journal Article262 79 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: without files , Verwendung von Modelica zur Untersuchung des dynamischen Verhaltens des deutschen Primärnormals für Hochdruck-GaszählerIn diesem Artikel wird ein dynamisches Modell für die Rohrprüfstrecke, welche als deutsches Primärnormal für Hochdruck-Gaszähler verwendet wird, vorgestellt. In einer Rohrprüfstrecke wird der Volumenstrom mit Hilfe der Zeit ermittelt, die ein Kolben in einem Messrohr benötigt, um eine bestimmte Strecke zurück zu legen. Schwankungen der Kolbengeschwindigkeit über der Messzeit können einen Einfluss auf die Messungenauigkeit haben, wenn diese nicht entsprechend berücksichtigt werden. Das Modell im Sprachstandard Modelica wurde entwickelt, um Wege zu finden, diese Messungenauigkeit zu verringern. Die Validierung des Modells zeigt eine hohe Übereinstimmung von Simulationsergebnissen und Messergebnissen in einem bestimmten Volumenstrombereich. Eine Reduktion des Kolbengewichtes, eine Variation der Schaltdauer des Startventils und die Integration eines Strömungsgleichrichters verringern die Schwankungen der Kolbengeschwindigkeit im Modell deutlich. Die schnelle und kostgengünstige Erstellung der Simulationsergebnisse zeigt die Vorzüge eines Modellierungsansatzes.Publicationtype: Journal Article62