5 results
Now showing1 - 5 of 5
- Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: without files , Deep Learning for High Speed Optical Coherence Elastography with a Fiber Scanning Endoscope(IEEE, 2025-03); ; ; ; Tissue stiffness is related to soft tissue pathologies and can be assessed through palpation or via clinical imaging systems, e.g., ultrasound or magnetic resonance imaging. Typically, the image based approaches are not suitable during interventions, particularly for minimally invasive surgery. To this end, we present a miniaturized fiber scanning endoscope for fast and localized elastography. Moreover, we propose a deep learning based signal processing pipeline to account for the intricate data and the need for real-time estimates. Our elasticity estimation approach is based on imaging complex and diffuse wave fields that encompass multiple wave frequencies and propagate in various directions. We optimize the probe design to enable different scan patterns. To maximize temporal sampling while maintaining three-dimensional information we define a scan pattern in a conical shape with a temporal frequency of 5.05 kHz. To efficiently process the image sequences of complex wave fields we consider a spatio-temporal deep learning network. We train the network in an end-to-end fashion on measurements from phantoms representing multiple elasticities. The network is used to obtain localized and robust elasticity estimates, allowing to create elasticity maps in real-time. For 2D scanning, our approach results in a mean absolute error of 6.31 ± 5.76 kPa compared to 11.33 ± 12.78 kPa for conventional phase tracking. For scanning without estimating the wave direction, the novel 3D method reduces the error to 4.48 ± 3.63 kPa compared to 19.75 ± 21.82 kPa for the conventional 2D method. Finally, we demonstrate feasibility of elasticity estimates in ex-vivo porcine tissue.Publicationtype: Journal Article22 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: without files , Motion-compensated OCT imaging of laryngeal tissue(SPIE, 2024-02); ;Kulas, Marica; ; Breda, Philippe C.The increasing incidence of laryngeal carcinomas requires approaches for early diagnosis and treatment. In clinical practice, white light endoscopy of the laryngeal region is typically followed by biopsy under general anesthesia. Thus, image based diagnosis using optical coherence tomography (OCT) has been proposed to study sub-surface tissue layers at high resolution. However, accessing the region of interest requires robust miniature OCT probes that can be forwarded through the working channel of a laryngoscope. Typically, such probes generate A-scans, i.e., single column depth images, which are rather difficult to interpret. We propose a novel approach using the endoscopic camera images to spatially align these A-scans. Given the natural tissue motion and movements of the laryngoscope, the resulting OCT images show a three-dimensional representation of the sub-surface structures, which is simpler to interpret. We present the overall imaging setup and the motion tracking method. Moreover, we describe an experimental setup to assess the precision of the spatial alignment. We study different tracking templates and report root-mean-squared errors of 0.08mm and 0.18mm for sinusoidal and freehand motion, respectively. Furthermore, we also demonstrate the in-vivo application of the approach, illustrating the benefit of spatially meaningful alignment of the A-scans to study laryngeal tissue.Publicationtype: Conference Paper12 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: without files , A Miniature Dual-Fiber Probe for Quantitative Optical Coherence Elastography(2023-11); ; ; ; Optical coherence elastography (OCE) allows for high resolution analysis of elastic tissue properties. However, due to the limited penetration of light into tissue, miniature probes are required to reach structures inside the body, e.g., vessel walls. Shear wave elastography relates shear wave velocities to quantitative estimates of elasticity. Generally, this is achieved by measuring the runtime of waves between two or multiple points. For miniature probes, optical fibers have been integrated and the runtime between the point of excitation and a single measurement point has been considered. This approach requires precise temporal synchronization and spatial calibration between excitation and imaging. We present a miniaturized dual-fiber OCE probe of diameter allowing for robust shear wave elastography. Shear wave velocity is estimated between two optics and hence independent of wave propagation between excitation and imaging. We quantify the wave propagation by evaluating either a single or two measurement points. Particularly, we compare both approaches to ultrasound elastography. Our experimental results demonstrate that quantification of local tissue elasticities is feasible. For homogeneous soft tissue phantoms, we obtain mean deviations of and for single-fiber and dual-fiber OCE, respectively. In inhomogeneous phantoms, we measure mean deviations of up to and for single-fiber and dual-fiber OCE, respectively. We present a dual-fiber OCE approach that is much more robust in inhomogeneous tissues. Moreover, we demonstrate the feasibility of elasticity quantification in ex-vivo coronary arteries. This study introduces an approach for robust elasticity quantification from within the tissue.Publicationtype: Journal Article37 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: without files , An approach for needle based optical coherence elastography measurements(Springer, 2017-09-04); ; ; ; While navigation and interventional guidance are typically based on image data, the images do not necessarily reflect mechanical tissue properties. Optical coherence elastography (OCE) presents a modality with high sensitivity and very high spatial and temporal resolution. However, OCE has a limited field of view of only 2–5 mm depth. We present a side-facing needle probe to image externally induced shear waves from within soft tissue. A first method of quantitative needle-based OCE is provided. Using a time of flight setup, we establish the shear wave velocity and estimate the tissue elasticity. For comparison, an external scan head is used for imaging. Results for four different phantoms indicate a good agreement between the shear wave velocities estimated from the needle probe at different depths and the scan head. The velocities ranging from 0.9–3.4 m/s agree with the expected values, illustrating that tissue elasticity estimates from within needle probes are feasible.Publicationtype: Conference Paper153 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: without files , A concept for fail safe robotic needle insertion in soft tissue(2015-03); ; ; This paper presents a concept of automatic needle placement for brachytherapy. For the success of this minimally invasive treatment, a precise and safe placement of needles inside soft tissue is fundamental. The presented concept incorporates information about the needle as well as the tissue to find a suitable needle trajectory. A patient-specific tissue model is derived from different imaging modalities and updated during the insertion. Essential for this concept is that during the robotic placement of the needle, it is continuously verified if proceeding is safe.Publicationtype: Conference Paper121