7 results
Filters
Settings
Now showing1 - 7 of 7
- Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: with files , A review of deep learning-based unsupervised anomaly detection in brain MRI(Elsevier, 2026-07-01); ; ; ; The manual assessment of brain Magnetic Resonance Imaging (MRI) scans can be labor-intensive and time-consuming for radiologists. Deep Learning methods have demonstrated the potential to aid this process. However, their effectiveness relies on the availability of large, annotated data sets. Unsupervised Anomaly Detection (UAD) presents a promising alternative, offering the potential to identify and localize anomalies without per-pixel annotations. Instead, a normative distribution is learned using healthy data, enabling the identification of abnormalities as deviations. This allows UAD methods to detect abnormalities that were unseen during training. This appealing feature has led to numerous studies proposing innovations and novel approaches. In this work, we provide a review of the literature and systematically collect and compare the proposed approaches. We observe that UAD has made significant advancements in brain MRI analysis. However, individual approaches are often evaluated in different contexts, i.e., changes in acquisition parameters, pre- and post-processing, and anomaly scoring. This variability makes it challenging to assess which models perform best, underscoring the need for comprehensive comparative studies concerning the specific context of MRI scans. Our collection, featuring public data sets, research studies, and open implementations, is available at our GitHub repository https://github.com/FinnBehrendt/Unsupervised-Anomaly-Detection-in-Brain-MRI .Publicationtype: Review Article14 26 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: without files , Diffusion models with ensembled structure-based anomaly scoring for unsupervised anomaly detectionSupervised deep learning techniques show promise in medical image analysis. However, they require comprehensive annotated data sets, which poses challenges, particularly for rare diseases. Consequently, unsupervised anomaly detection (UAD) emerges as a viable alternative for pathology segmentation, as only healthy data is required for training. However, recent UAD anomaly scoring functions often focus on intensity only and neglect structural differences, which impedes the segmentation performance. This work investigates the potential of Structural Similarity (SSIM) to bridge this gap. SSIM captures both intensity and structural disparities and can be advantageous over the classical l1 error. However, we show that there is more than one optimal kernel size for the SSIM calculation for different pathologies. Therefore, we investigate an adaptive ensembling strategy for various kernel sizes to offer a more pathology-agnostic scoring mechanism. We demonstrate that this ensembling strategy can enhance the performance of DMs and mitigate the sensitivity to different kernel sizes across varying pathologies, highlighting its promise for brain MRI anomaly detection.Publicationtype: Conference Paper10 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: with files , A systematic approach to deep learning-based nodule detection in chest radiographsLung cancer is a serious disease responsible for millions of deaths every year. Early stages of lung cancer can be manifested in pulmonary lung nodules. To assist radiologists in reducing the number of overseen nodules and to increase the detection accuracy in general, automatic detection algorithms have been proposed. Particularly, deep learning methods are promising. However, obtaining clinically relevant results remains challenging. While a variety of approaches have been proposed for general purpose object detection, these are typically evaluated on benchmark data sets. Achieving competitive performance for specific real-world problems like lung nodule detection typically requires careful analysis of the problem at hand and the selection and tuning of suitable deep learning models. We present a systematic comparison of state-of-the-art object detection algorithms for the task of lung nodule detection. In this regard, we address the critical aspect of class imbalance and and demonstrate a data augmentation approach as well as transfer learning to boost performance. We illustrate how this analysis and a combination of multiple architectures results in state-of-the-art performance for lung nodule detection, which is demonstrated by the proposed model winning the detection track of the Node21 competition. The code for our approach is available at https://github.com/FinnBehrendt/node21-submit.Publicationtype: Journal ArticleScopus© Citations 2 25 57 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: without files , Nodule detection in chest radiographs with unsupervised pre-trained detection transformers(IEEE, 2023-09-01); ; ; ; The detection of pulmonary nodules in chest x-rays is important for early observation and monitoring of lung cancer which is a major reason for death worldwide. However, detecting nodules from x-rays is challenging as nodules are easily overseen by radiologists. Convolutional neural networks (CNN) show promising results in supporting the clinical practice by automatic lung nodule detection and localization. Recently, attention-based Vision Transformers have been successfully applied in computer vision tasks. For object detection, end-to-end solutions have been proposed that reduce the amount of encoded prior knowledge and manual postprocessing. This is desirable particularly for medical applications where data domains often vary.In this work, we evaluate the application of Detection Transformers for nodule detection in chest x-rays and compare them against four CNN-based baseline object detection algorithms. To overcome the data inefficiency of Vision Transformers, we investigate the use of self-supervision from large-scale data sources. Our results demonstrate the high performance of transformer-based object detectors, by consistently outperforming CNN-based baselines on the Node21 data set. Furthermore, we demonstrate that self-supervision improves the detection performance without the costly requirement of collecting annotated data.Publicationtype: Conference Paper23 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: with files , Multiple instance ensembling for paranasal anomaly classification in the maxillary sinus(Springer, 2023-07-21); ; ; ; Purpose : Paranasal anomalies are commonly discovered during routine radiological screenings and can present with a wide range of morphological features. This diversity can make it difficult for convolutional neural networks (CNNs) to accurately classify these anomalies, especially when working with limited datasets. Additionally, current approaches to paranasal anomaly classification are constrained to identifying a single anomaly at a time. These challenges necessitate the need for further research and development in this area. Methods : We investigate the feasibility of using a 3D convolutional neural network (CNN) to classify healthy maxillary sinuses (MS) and MS with polyps or cysts. The task of accurately localizing the relevant MS volume within larger head and neck Magnetic Resonance Imaging (MRI) scans can be difficult, but we develop a strategy which includes the use of a novel sampling technique that not only effectively localizes the relevant MS volume, but also increases the size of the training dataset and improves classification results. Additionally, we employ a Multiple Instance Ensembling (MIE) prediction method to further boost classification performance. Results : With sampling and MIE, we observe that there is consistent improvement in classification performance of all 3D ResNet and 3D DenseNet architecture with an average AUPRC percentage increase of 21.86 ± 11.92% and 4.27 ± 5.04% by sampling and 28.86 ± 12.80% and 9.85 ± 4.02% by sampling and MIE, respectively. Conclusion : Sampling and MIE can be effective techniques to improve the generalizability of CNNs for paranasal anomaly classification. We demonstrate the feasibility of classifying anomalies in the MS. We propose a data enlarging strategy through sampling alongside a novel MIE strategy that proves to be beneficial for paranasal anomaly classification in the MS.Publicationtype: Journal ArticleScopus© Citations 2 27 105 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: without files , Unsupervised Anomaly Detection of Paranasal Anomalies in the Maxillary SinusDeep learning (DL) algorithms can be used to automate paranasal anomaly detection from Magnetic Resonance Imaging (MRI). However, previous works relied on supervised learning techniques to distinguish between normal and abnormal samples. This method limits the type of anomalies that can be classified as the anomalies need to be present in the training data. Further, many data points from normal and anomaly class are needed for the model to achieve satisfactory classification performance. However, experienced clinicians can segregate between normal samples (healthy maxillary sinus) and anomalous samples (anomalous maxillary sinus) after looking at a few normal samples. We mimic the clinicians ability by learning the distribution of healthy maxillary sinuses using a 3D convolutional auto-encoder (cAE) and its variant, a 3D variational autoencoder (VAE) architecture and evaluate cAE and VAE for this task. Concretely, we pose the paranasal anomaly detection as an unsupervised anomaly detection problem. Thereby, we are able to reduce the labelling effort of the clinicians as we only use healthy samples during training. Additionally, we can classify any type of anomaly that differs from the training distribution. We train our 3D cAE and VAE to learn a latent representation of healthy maxillary sinus volumes using L1 reconstruction loss. During inference, we use the reconstruction error to classify between normal and anomalous maxillary sinuses. We extract sub-volumes from larger head and neck MRIs and analyse the effect of different fields of view on the detection performance. Finally, we report which anomalies are easiest and hardest to classify using our approach. Our results demonstrate the feasibility of unsupervised detection of paranasal anomalies from MRIs with an AUPRC of 85% and 80% for cAE and VAE, respectively.Publicationtype: Conference Paper25 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: with files , Data-efficient vision transformers for multi-label sisease classification on chest radiographs(De Gruyter, 2022-07); ; ; ; Radiographs are a versatile diagnostic tool for the detection and assessment of pathologies, for treatment planning or for navigation and localization purposes in clinical interventions. However, their interpretation and assessment by radiologists can be tedious and error-prone. Thus, a wide variety of deep learning methods have been proposed to support radiologists interpreting radiographs. Mostly, these approaches rely on convolutional neural networks (CNN) to extract features from images. Especially for the multi-label classification of pathologies on chest radiographs (Chest X-Rays, CXR), CNNs have proven to be well suited. On the Contrary, Vision Transformers (ViTs) have not been applied to this task despite their high classification performance on generic images and interpretable local saliency maps which could add value to clinical interventions. ViTs do not rely on convolutions but on patch-based self-attention and in contrast to CNNs, no prior knowledge of local connectivity is present. While this leads to increased capacity, ViTs typically require an excessive amount of training data which represents a hurdle in the medical domain as high costs are associated with collecting large medical data sets. In this work, we systematically compare the classification performance of ViTs and CNNs for different data set sizes and evaluate more data-efficient ViT variants (DeiT). Our results show that while the performance between ViTs and CNNs is on par with a small benefit for ViTs, DeiTs outperform the former if a reasonably large data set is available for training.Publicationtype: Journal ArticleScopus© Citations 3 28 51